Skip to content


The First-Due and Buildings on fire

No comments

 

The First-Due and Buildings on fire

The First-Due and Buildings on fire
The ability for the first-arriving company, company officer or commander to perform an accurate identification of building type and classification are formulative toward anticipating variables in structural integrity and resiliency to the effects of extreme fire behavior, accelerated fire load package growth rates and intensity levels typically encountered in today’s composition and arrangement of buildings and their associated construction systems during initial and sustained fire suppression.

Arriving companies and personnel at a structure fire must be able to rapidly and accurately identify key elements of a building, process that data based on a widening field of variables present on today’s evolving Fireground and implement timely actions that address prioritized actions requiring intervention.

Building Performance

The identification, assessment, probability, predictability and intrinsic characteristics of the building and its expected performance under fire conditions must be identified, assessed and integrated into an adaptive fire management model and flexible incident action plan.

In other words, arriving companies and personnel at a structure fire need to be able to rapidly and accurately identify key elements of a building, process that data based upon a widening field of variables present on today’s evolving fireground and implement timely actions that address prioritized actions requiring intervention.   Deterministic fireground models for size-up and suppression have to give way to a more expandable stochastic model of assessment. Key to this is having a broad and well developed foundation of building knowledge.

  • Link to recent article, HERE

The Compartment and the Company

No comments

 

The Compartment and the Company:
Tactical Fireground successes are measured by the abilities, determination and fortitude of the Company and the leadership of the Company Officer to interface with the evolving fire conditions within the Compartment and Envelope of the Building.If the Company understands and knows the buildings and occupancy risks of its first-due; can efficiently assess the building and corresponding fire conditions and can
recognize hazards, risks and operational vulnerabilities; align tactical priorities and execute tasks with precision and proficiencies, then there is a high degree of confidence strategic objectives can be achieved and the incident mitigated with limited adverse collateral.

How effective are you as an officer?

  • How about the other officers?
  • What about the company?
  • Capable, skilled, proficient?
  • Does your officer and company take time to look over the building (interior/ exterior) once an incident, alarm or run is done?

Are you “looking” at key issues that affect the Building? Start reexamining the compartment and your company: risk and capabilities, it’s that important.

The most important element on the Fireground

Taking it to the Streets: “All Companies Stand-By”: Transmitting the Box for….Your Street on this Day

No comments

 

Transmitting the Box

Taking it to the Streets: “All units stand-by: Transmitting the Box for….Your Street on this DayThe importance of knowing your first-due, surrounding response districts, as well as greater alarm, mutual and automatic aid response areas …is fundamental towards achieving operational excellence and maintaining firefighter safety.

The fact that at times, our surroundings do become a blur and fade into the background does occur and should be recognized as a gap and corrected.

Company and Command Officer Responsibilities demand that you know your buildings intimately and have the knowledge base and experience to put Building Construction, Occupancy, Fire in the Compartment and Strategies & Tactics together in an orchestrated manner consistent with risk, demands and requirements dictated by the evolving incident.You know that quiet street you pass daily on your way to “other runs”, or that may not have necessarily required agency service in a while; have you looked at the construction and building features before you’re now showing up first-due with heavy fire showing, and multiple incident priorities all demanding immediate attention?

Take a look at the images from our past post and this one; run through your head what the street looks like (pre-event) and what parameters and factors you’re seeing. Do the same with the fire incident scene and see if you can match pre-incident situational awareness and pre-fire planning insights with what you might be confronting from the front seat or riding backwards….Understand and Know your world….it’s just a matter of time before those bells will be going off and the radio will be crackling….Engine 21 respond to…. For a report of a structure fire.

  • Checkout other interactions on Buildingsonfire on Facebook HERE and don’t forget to to LIKE and pass the link along

Central Ohio FOOLS Training Opportunity

No comments

 

 

Central Ohio FOOLS presents

Adaptive Fireground Management for the Company and Command Officer

 This program presents insights into emerging concepts and methodologies related to the unique challenges during combat structural fire engagement that require refined strategic, tactical and operational modeling due to extreme fire behavior, building construction and occupancy risk. The principles of Adaptive Fire Ground Management (AFM) will be presented along with integrated discussions on:

  • Predictive Risk Management, Command Resiliency, Tactical Patience & integration of Five-Star CommandTM model will be presented with discussion on key Building Construction Systems and Occupancy Risk factors for company effectiveness, operational excellence and firefighter safety
  • The program will integrate key case studies, lessons from the fireground, insights into emerging fire ground tactical theory with a focus of understanding occupancy risk with today’s Buildings on fire.  
  • This is an interactive and thought provoking program that challenges conventional fire service paradigms and explores leading edge theories and fire service discussion points from across the American Fire Service profession.
  • This program is for ALL levels of rank and experience, not just officers.

Friday  March 8th, 2013 • 0900-1600 hrs. Ÿ $50.00 per Student

Registration Opens at 8am Columbus FF Union Hall

Station 67, 379 Broad Street, Columbus, OH 43215

CEU: 6 hrs. Provided by Columbus State Community College | Meet & Greet Immediately Following

 Point of Contact: Jason Kay (614) 65-FOOLS, fools@centralohiofools.com

Registration: www.centralohiofools.com via PayPal

 Visit Buildingsonfire.com ∙ Buildingsonfire on Facebook and Twitter  

Program PDF: HERE: CentralOhio_ FOOLS

Testimony Continues from 2011 LAFD LODD Fire at Luxury Hollywood Hills Home in Hearing for Architect

No comments

February 2011 fire in the Hollywood Hills

A veteran fire captain testified Wednesday that he was trapped in debris that fell from a ceiling during a February 2011 fire at a luxury home in the Hollywood Hills, where another longtime firefighter suffered fatal injuries.

Called to testify during a hearing to determine if an architect who designed and oversaw the construction of the home should stand trial for involuntary manslaughter, Los Angeles Fire Department Capt. Edward Watters told Superior Court Judge Michael Tynan that he “heard a loud bang” and suddenly found himself lying on his back with a “lot of weight on my chest.”

Gerhard Albert Becker—a 48-year-old German national who owned, designed and built the home —is charged in connection with the death of firefighter Glenn Allen, 61.

Allen, a 36-year veteran of the LAFD, died two days after being struck by a portion of the ceiling during the Feb. 16, 2011, blaze.

Glenn Allen, 36-year veteran LAFD

  • More from the Hollywood Patch; HERE

  • Previous Posts from

  • CommandSafety.com HERE

  • Other Previous Postings HERE , HERE, HERE and HERE

Chicago Fire Captain Herbie Johnson remembered for his kindness, humor, bravery

No comments

Captain Herbie Johnson, CFD

 

Photo By Tim Olk (all rights reserved)
http://olkee.smugmug.com/Mabas-Division-9-City-Of/CFD-Funerals/Chicago-Detment/26417819_vPkW9J#!i=2203991836&k=XDgP8TT

 

  • Chicago Tribune Photos, HERE
  • Tim Olk Photos, HERE
  • Chicago Tribune, HERE
  • “We could not be prouder of you,”  brother of fallen firefighter says Sun-Times HERE
  • See CommandSafety.com for a complete accounting of the event, HERE
  • Family of fallen firefighter: ‘A hero for our city’ from the Chicago Tribune, HERE

  • Related
  • Deadly fire on Chicago's South Side
  • PHOTOS:  Deadly fire on Chicago’s South Side

 

 

 

Photo: E. Jason Wambsgans/Chicago Tribune

 

What will define you as a Firefigher, as an Officer…as a person?

 

 

“You don’t need a last name for Herbie. Everybody knew Herbie”; Chicago Fire Capt. Herbie Johnson

No comments

Chicago firefighter Herbert Johnson, left, poses with Chicago Fire Commissioner Jose Santiago, right, after Johnson was promoted to the rank of captain. Johnson died from injuries sustained while fighting a house fire on the South Side. — Chicago Fire Department

 ”You don’t need a last name for Herbie. Everybody knew Herbie”.   A beloved firefighter, Fire officer, father and husband died in the line of duty on Friday November 2, in the City of Chicago protecting the citizens of his city working with the companies assigned to the structure fire alarm.

Chicago Captain Herbert Johnson, 54, suffered second- and third-degree burns during fire suppression operations being conducted in the attic of the residential house at 2315 West 50th Place, according to Chicago FD officials and published media reports. The 32-year veteran of the Chicago Fire Department died Friday night after he and another firefighter were injured in a blaze that spread quickly through the 2-1/2 story wood frame house. A second firefighter, FF Brian Woods was also injured and was reported in good condition at Advocate Christ Medical Center in Oak Lawn, according to a department spokeswoman, and was subsequently released. Chicago fire investigators are considering the possibility that a malfunctioning water heater sparked the fire that killed Capt. Herbert Johnson, a Fire Department spokesman said Saturday.

  • See CommandSafety.com for a complete accounting of the event, HERE
  • Family of fallen firefighter: ‘A hero for our city’ from the Chicago Tribune, HERE

Captain Johnson, was promoted from lieutenant this summer and was assigned to Engine Co. 123 in Back of the Yards Section of Chicago for the night tour but normally worked all around the City of Chicago.

Capt. Johnson from a 2006 Sun-Times photo

The following exerpt from the Chicago Tribune helps define the type of firefighter Capt. Johnson was:

http://www.chicagotribune.com/news/local/ct-met-firefighter-killed-folo-20121104,0,5331508.story

Johnson’s influence on everyone he met was visible Saturday, with shrines at the site of his death and trees in his family’s Morgan Park neighborhood decorated with purple and black bows.

A 32-year veteran of the department, Johnson volunteered in 2001 to help with rescue efforts in New York after the 9/11 attacks. As a lieutenant in 2007, he received a Medal of Honor for outstanding bravery or heroism, the state’s highest accolade for firefighters — the result, his family said, of helping rescue children the year before from a burning building on the South Side.

Friends and family remembered him mostly for his jovial personality and tender heart, a burly man with a beaming smile who once took a sewing class so he could make a First Communion dress for his daughter.

Johnson and his sister, Julie, even went to clown school together, said their brother John Johnson, a Chicago police officer. That sister, a former police officer who is now a nurse, celebrated her birthday Friday, the day of Johnson’s death, family members said.

Their father worked for the city in the Streets and Sanitation Department, John Johnson said, and their grandfathers were Chicago police officers.

The eldest of eight children, Johnson always knew he wanted to be a firefighter, said his family members, many of whom are also in public service.

“He lived for it,” brother-in-law McMahon, said.

“He died for it,” John Johnson added.

 From the Chicago Tribune (HERE);

Just like every little boy that’s grown up in the last 20 years wanted to be Michael Jordan or Brian Urlacher, every firefighter that worked with him wanted to be Herbie,” said Tim O’Brien, a spokesman with Chicago Fire Fighters Union Local 2. “You aspired to be more like him in every way of life.”

Colleagues said Johnson spent the last several years working as an instructor at the Fire Academy. Generous and kind, he never missed a Fire Department fundraising event, they said. His helpful nature also extended beyond the firehouse, friends said, through coaching youth sports and volunteering at his church parish.

He always had a funny story and often left fellow firefighters in stitches, sometimes through his own distinctive belly laugh, colleagues said.

From The Chicago Sun-Times (HERE):

“He was always a hero to us and now he’s a hero for our city,” McMahon said. “Herbie never wanted glory or notoriety. Instead, all he wanted was to make Chicago a safer place for other members of the city. So please, in Herbie’s honor, check your smoke detectors right now, give your kids a hug.”

Johnson was an easy man to know and love, said friend Tom Taff, who runs a camp for burn victims that Johnson helped support. The recently promoted captain personified joie de vivre, a man with a big laugh who drove fire engines in parades, cooked for charity ­— left an impression in the many places he offered his service.

 

Readings and Learnings

Additional Coverage and Links

  • From Chicago WGNTV, HERE
  • From the Chicago Tribune, HERE and HERE
  • From the Chicago Sun Times, HERE
  • Photo Gallery from the Sun-Times, HERE
  • Photo Gallery from the Chicago Tribune, HERE
  • Aerial Fireground Operations, Chicago ABC 7 News, HERE
  • Google Maps; StreetView Images, HERE
  • Chicago CBS, HERE
  • 2007 Illinois Fallen Firefighter Memorial and Firefighting Medal of Honor Ceremony, HERE
  • Remembering Capt. Herbie Johnson: “To Know Him, Was to Love Him” HERE

 

 

Photo Credit: Tim Olk
https://www.facebook.com/tim.olk.75
http://olkee.smugmug.com/

VISITATION: Wednesday, November 7, 2012 at St. Rita High School, 7740 S. Western from 3-9 PM.
FUNERAL MASS: Thursday, November 8, 2012 at St. Rita High School at 11:00 AM

 

 

 

Family, friends gather to mourn fallen firefighter Herbert Johnson, Chicago Sun-Times Additional Video HERE

 

An Officer who Made a Difference: Remembrance

No comments
Captain Patrick “Paddy” Brown, FDNY

Remembrance, One of Many Stories: One of the 343…  

On September 11, 2001, Captain Patrick Brown and eleven men from FDNY Ladder 3 responded to the attacks at the World Trade Center. His firehouse, Ladder 3, is located in very close proximity to the Twin Towers so his was one of the first fire companies on the scene. Along with so many other rescue workers, the men of Ladder 3 participated in perhaps the most successful rescue effort in U.S. history. These rescue workers, at their own peril, managed to safely evacuate over 25,000 people from those burning towers. It is believed that Paddy and his men were on the 40th floor of the North Tower with 30 or 40 severely burned people when that tower fell.

 He was an extraordinary officer and firefighter; Captain Patrick Brown was passionate, intense, complicated, humble, and an inspiration to both those who knew him and those who are just now finding out about this incredible man. He’ll be remembered as a devoted friend, a dedicated firefighter, a warrior, and someone who made a difference.

One of the many stories of extraordinary Company Officers, Firefighters, Commanders and Chief Officers… of the FDNY 343….

Ladder 3 Last Dispatch 1 Hour Before The North Tower Collapse HERE

 

 

 

Fire Dynamics Simulation of 2011 Baltimore County LODD- 30 Dowling Circle

No comments

Operations at 30 Dowling Circle 01.19.2011 Box 11-09

 On Wednesday, January 19, 2011, a fire occurred in an apartment building located in the Hillendale section of Baltimore County, Maryland. This fire resulted in the line of duty death (LODD) of volunteer firefighter Mark G. Falkenhan, who was operating as the acting lieutenant on Squad 303 . Upon their arrival, FF Falkenhan and a second firefighter from Squad 303 deployed to the upper floors of the apartment building to conduct search and rescue operations. Other fire department units were already involved with both firefighting operations and effecting rescues of trapped civilians.

During these operations, FF Falkenhan and his partner became trapped in a third floor apartment by rapidly spreading fire and smoke conditions. The second firefighter was able to self-egress the building by diving headfirst down a ladder on the front (address side) of the building. FF Falkenhan declared a “MAYDAY” and implemented “MAYDAY” procedures, but was unable to escape or be rescued.

FF Falkenhan was located and removed via a balcony on the third floor in the rear of the building. Resuscitative efforts began immediately upon removal from the balcony, and continued en route to the hospital. FF Falkenhan succumbed to his injuries and was pronounced deceased at the hospital.

Mark Gray Falkenhan had dedicated his life to serving others. He perished in the line of duty on January 19, 2011 while performing search and rescue operations at a multi-alarm apartment fire in Hillendale, Baltimore County (Maryland). He was 43 years old.

 

Firefighter Mark Falkenhan

30 Dowling Circle

 

The Baltimore County (MD) Fire Department published the Line of Duty Death Investgation Report of the 30 Dowling Circle Fire recently.

The report was written by a Line of Duty Death Investigation Team comprised of departmental members, including representatives of the local firefighters’ union and the Baltimore County Volunteer Firemen’s Association.

An overview and executive narrative of the final report (PDF) on the apartment fire where Volunteer Firefighter Mark Falkenhan sustained fatal injuries was posed on CommandSafety.com HERE.

FF Mark Falkenhan

 On Wednesday, January 19, 2011, a fire occurred in an apartment building located in the Hillendale section of Baltimore County, Maryland. This fire resulted in the line of duty death (LODD) of volunteer firefighter Mark G. Falkenhan, who was operating as the acting lieutenant on Squad 303 (for purposes of this report, Mark will be referred to as FF Falkenhan).

Upon their arrival, FF Falkenhan and a second firefighter (FF # 2) from Squad 303 deployed to the upper floors of the apartment building to conduct search and rescue operations. Other fire department units were already involved with both firefighting operations and effecting rescues of trapped civilians.

During these operations, FF Falkenhan and FF # 2 became trapped in a third floor apartment by rapidly spreading fire and smoke conditions. FF # 2 was able to self-egress the building by diving headfirst down a ladder on the front (address side) of the building. FF Falkenhan declared a “MAYDAY” and implemented “MAYDAY” procedures, but was unable to escape or be rescued.

FF Falkenhan was located and removed via a balcony on the third floor in the rear of the building. Resuscitative efforts began immediately upon removal from the balcony, and continued en route to the hospital. FF Falkenhan succumbed to his injuries and was pronounced deceased at the hospital.

The investigating team examined any and all data available, including independent analysis of the self contained breathing apparatus (SCBA), turnout gear and autopsy report. The Bureau of Alcohol, Tobacco, Firearms and Explosives (ATF) produced a fire model to assist with evaluating fire behavior. Multiple site inspections were conducted. Extensive interviews were conducted by the team which also attended those conducted by investigators from the National Institute for Occupational Safety and Health (NIOSH). Photographic and audio transcripts were also thoroughly analyzed. A comprehensive timeline of events was developed. All information used to make decisions regarding recommendations was corroborated by at least two sources.

  • In fairness to those units involved in this incident, the investigating team had the advantage of examining this incident over the period of several months. Furthermore, given the size and nature of the event, and the fact that arriving crews were met with serious fire conditions and several residents trapped and in immediate danger, all personnel should be commended for their efforts for performing several rescues which prevented an even greater tragedy.
  • The team did not identify a particular primary reason for FF Falkenhan’s death.
  • What were identified were many secondary issues involving but not limited to crew integrity, incident command, strategy and tactics, and communications.
  • These issues are identified and discussed, and recommendations are made in appropriate sections of the report, as well as in a consolidated format in the Report Appendix.

Some of the issues identified in this report may require some type of change to current practices, policies, procedures or equipment. Most, however, do not. Specifically, the analysis and recommendations regarding Incident Command and Strategy and Tactics show that if current policies and procedures are adhered to, the opportunity for catastrophic problems may be reduced.

  • Mark Falkenhan was a well-respected and experienced firefighter.
  • He died performing his duties during a very complex incident with severe fire conditions and unique fire behavior coupled with the immediate need to perform multiple rescues of victims in imminent danger.
  • It would be easy if one particular failure of the system could be identified as the cause of this tragedy.
  • We could fix it and move on. Unfortunately it is not that simple.
  • No incident is “routine”. Mark’s death and this report reinforce that fact.

On Wednesday, January 19, 2011 at 1816 hours, a call was received at the Baltimore County 911 Center from a female occupant at 30 Dowling Circle in the Hillendale section of Baltimore County. The caller stated that her stove was on fire and the fire was spreading to the surrounding cabinets. Fire box 11-09 was dispatched by Baltimore County Fire Dispatch (Dispatch) at 1818 hours consisting of four engine companies, two truck companies, a floodlight unit, and a battalion chief. All units responded on Talkgroup 1-2.

The location, approximately one mile from the first dispatched engine company, is a three story garden-type apartment complex, with brick construction and a composite shingle, truss supported roof. The fire building contained a total of six apartments divided by a common enclosed stairway in the center with one apartment on the left and one to the right of the stairs.

 

Fire Dynamics Simulation of 2011 Baltimore County LODD- 30 Dowling

Fire Dynamics Analysis and Insights

 

INTRODUCTION:

Assistance from the Bureau of Alcohol, Tobacco, Firearms and Explosives (ATF) Fire Research Laboratory (FRL) was requested for a fire at 30 Dowling Circle by the Baltimore County Fire Investigation Division (FID) through the ATF Baltimore Field Division on the night of January 19, 2011.

ATF Fire Protection Engineers were asked to utilize engineering analysis methods, including computer fire modeling, to assist with determining the route of fire spread and the events that led to the firefighter MAYDAY and subsequent Line of Duty Death.

Download the REPORT HERE

BACKGROUND:

Working closely with the Post Incident Analysis Team, the ATF Fire Research Laboratory created a computer simulation of the garden apartment building using Fire Dynamics Simulator (FDS). FDS is a computational fluid dynamics (CFD) modeling program developed by the National Institute of Standards and Technology (NIST).

FDS utilizes mathematical calculations to predict the flow of heat, smoke and other products of fire. Smokeview, a post-processer computer program also produced by NIST, was then used to visualize the mathematical output from FDS. The most current available versions of both programs were used: FDS 5.5.3 and Smokeview 5.6. Below are photographs of the front and rear of the fire building next to an image of the same building constructed in FDS.

Figure 01. 30 Dowling Street

 

Figure 2. FDS representation of the front of 30 Dowling Circle showing the terrace (T), second (A) and third (B) levels.

 

The garden apartment building at 30 Dowling Circle was attached to two similar garden apartment buildings, one on each side. The fire damage was isolated to 30 Dowling Circle, so the exposure buildings were not included in the computer fire model. The entire six unit garden apartment building was modeled in FDS, including the patio and balconies on the rear of the building. FDS works by dividing a space into cubical “grid cells” for calculation purposes. FDS then computes various CFD calculations for each grid cell to predict the movement of mass, energy, momentum and species throughout a three-dimensional space.

The Dowling Circle model consisted of 2,560,000 total grid cells that were each 3.9 inch (10 cm) cubes. The model was used to simulate a total elapsed real time of 27.5 minutes, beginning before the 911 call and ending just after flashover of the third floor and the firefighter MAYDAY.

The model was synchronized in real time with the fireground audio throughout the duration of the fire.

Fiqure 03 and 04

 

FDS has been validated to predict the movement of heat and smoke throughout a compartment, however the accuracy of fire modeling depends on it being used appropriately by a trained user that is aware of its limitations. Due to lack of knowledge about the exact material properties for the various furnishings and other available fuels, a user-specified fire progression was used for this application.

For flame and fire gas movement after consumption of the original burning fuel packages, the fire model calculated smoke and ventilation flow paths through the building and was used to gain a better understanding of the rapid fire growth leading to flashover of the stairwell and third floor.

  • In addition, FDS was utilized to illustrate the complex route of fire spread through the building as verified by witness statements, firefighter interviews, photographs and burn patterns.
  • Input data for the computer model included heat release rate data and video from previous testing conducted by the ATF FRL and NIST.
  • Ambient weather data was also input into the model, including temperature, as well as wind direction and magnitude at the time of the fire. In addition, several alternative compartmentation scenarios were modeled to explore the possible effects of closed stairway apartment entrance doors on the spread of smoke and flames in the stairwell.
  • The statements of each firefighter were reviewed and their individual actions (breaking windows, opening doors, etc.) and observations (fire size, smoke conditions, etc.) were recorded on floor diagrams.

The actions and observations of the firefighters were then associated with specific times in the fireground audio to generate an overall event timeline. All events in the model are based on this master timeline of events. In addition, all photographs were time stamped and synchronized with the model. The Post Incident Analysis Team was consulted throughout the development of the event timeline and the computer fire model to ensure accuracy.

MODELING ANALYSIS:

1. Analysis of Fire Development in the Terrace Level

The fire originated on the stovetop of an occupied apartment on the right (south) side of the terrace level (apartment T2). Flames from a grease fire ignited kitchen cabinets, eventually causing the kitchen to flashover into the attached living room. Upon fire department arrival, a fully developed fire existed in the living room and kitchen of apartment T2. Prior to exiting the apartment, the occupant opened both the rear sliding door and the apartment entrance door in an attempt to ventilate smoke from the apartment.

 

Figure 06. A typical floor plan of the right side apartments at 30 Dowling Circle.

 

An analysis of the ventilation flow path through the apartment with FDS indicated that a significant unidirectional flow path existed up the stairs with an inlet at the rear terrace sliding door and outlet at the front apartment entrance door leading to the stairwell.

Figure 7. Smokeview frame of the rear of the building indicating the fire origin and smoke spread within the T2 apartment. Figure 8. View of smoke flow out of kitchen and open sliding glass door (center of photo) in the rear of apartment T2. Figure 9. Smokeview frame of flashover of the kitchen with flames extending into the living room. Flames also begin to extend out of the rear sliding door and impact the balcony above.

 

Figure 10. Ignition of second level balcony resulting from flame extension from living room.

 

This unidirectional flow path up the stairs is difficult to combat and is often experienced during basement fires as crews attempt to descend interior stairs. The model indicates sustained air temperatures in the stairwell of approximately 600 Fahrenheit (315 Celsius) at velocities of approximately 6 mph (2.7 m/s) from floor to ceiling as crews attempted to descend the stairs. This is consistent with statements from firefighting crews, who experienced extremely high heat conditions and indicated periodically seeing flames in the smoke layer flowing up the stairs.

The elevated air velocity of the stairwell flow path resulted in a high rate of convective energy transfer to the structural firefighting gear and high perceived temperatures as the firefighters attempted to descend the stairs. Firefighting crews flowed a hoseline down the stairs to combat the high temperatures; however no significant cooling was noticed by firefighters because the hose stream could not reach the seat of the fully developed fire in the kitchen area.

The crews were simply cooling the ventilation flow path without cooling the source of the energy in the apartment. It was not until a hose stream was directed through an exterior window and a portion of the fire was extinguished that gas temperatures and velocities began to decrease, allowing firefighters to make entry to the terrace apartment via the stairs.

Figure 12. Smokeview section frame showing unidirectional flow of approximately 600 Fahrenheit (315 Celsius) gases out of the stairwell entrance door

Front photo of unidirectional flow of smoke up stairwell from apartment T2. Note the high volume of smoke from floor to ceiling as the stairwell door serves as the flow path outlet. The ground ladder in the foreground was used to rescue an occupant on the third floor trapped by heavy smoke in the stairwell. (Refer to Figure 014)

Figure 014. Front photo of unidirectional flow of smoke up stairwell from apartment T2. Note the high volume of smoke from floor to ceiling as the stairwell door serves as the flow path outlet.

 

The first arriving engine, E-11, was staffed with a Captain, Lieutenant, Driver/Operator, and a Firefighter. Upon arrival at 1820 hours, the Captain gave a brief initial report describing a three story garden apartment with smoke showing from side Alpha: “The Captain of E-11 will have Command and we are initiating an aggressive interior attack with a 1 ¾” hand line”. Command also instructed the second due engine to bring him a supply line from the hydrant. 

A female resident (victim # 1) appeared in a third floor apartment window, Alpha/Bravo side (Apt. B-1), yelled for assistance, and threatened to jump. Smoke or fire was visible from any of the third floor windows. At 1823 hours, Command advised Dispatch that he had a rescue and that he was establishing Limited Command. Fire Dispatch was in the process of upgrading the response profile to an apartment fire with rescue when the responding Battalion Chief requested that the fire box be upgraded to a fire rescue box. While the Firefighter and Lieutenant prepared for entry into the building, the Captain and Driver/Operator extended a ladder to the 3rd floor apartment window and rescued the resident. The first attempt by the Firefighter and Lieutenant to make entry into the side Alpha entrance was unsuccessful due to the extreme heat and smoke conditions.

The second due engine, E-10, arrived at 1823 with staffing of a Captain, Lieutenant, Driver/Operator, and a Firefighter. At 1823, E-10’s crew brought a 4″ supply line to E-11 from the hydrant at Deanwood Rd. and Dowling Circle and assisted the first-in crew with fire attack.

  • The Captain from E-10 conferred with Command and was instructed to advance a second 1 ¾” hand line.
  • The window to the first floor right apartment (Apt. T-2) was removed, and the second 1 ¾” line was advanced to the building by the crew of E-10.
  • Fire attack was initiated through the removed window. At 1827, Command requested a second alarm.

At this time, heat and smoke conditions just inside the front door improved enough to allow the Firefighter and Lieutenant from E-11 to make entry through the front door and into the stairwell. There they encountered heavy, thick black smoke and high heat conditions coming up the stairs from the terrace level apartment. The Lieutenant reported that the doorway to the first floor apartment was orange with fire and he had to fight his way through heavy heat and smoke conditions to attack the fire in the first floor right apartment (Apt. T-2). Entry was made approximately 3 feet into the doorway when the Firefighter’s low air alarm began to sound, and he exited the building. A member from E-10’s crew replaced the Firefighter from E-11 on the hose line.

At the same time, the Captain from E-11 proceeded to the rear of the structure to complete his initial 360 degree size up. He noted that there was fire emanating from the open sliding doors on the first floor Charlie/Delta apartment (Apt. T-2), extending to the balcony above. E-1, staffed by a Captain, Driver/Operator, and two Firefighters arrived and completed the hookup of the supply line that had been laid to the hydrant by E-10. The rest of Engine 1’s crew grabbed tools and an extension ladder and reported to the Charlie side of the building.

Figure 015 Charlie Side ( Rear) Extension

The Photo above referenced as  Figure 015 shows conditions  from rear of flames in apartment T2 and extension to the balcony above. Note the relative minimal volume of smoke as the sliding door serves as the inlet for ventilation into the apartment. The smoke and heat is flowing in from the rear, through the apartment and up the stairs.

This unidirectional flow path up the stairs is difficult to combat and is often experienced during basement fires as crews attempt to descend interior stairs.

  • The model indicates sustained air temperatures in the stairwell of approximately 600 Fahrenheit (315 Celsius) at velocities of approximately 6 mph (2.7 m/s) from floor to ceiling as crews attempted to descend the stairs.
  • This is consistent with statements from firefighting crews, who experienced extremely high heat conditions and indicated periodically seeing flames in the smoke layer flowing up the stairs.
  • The elevated air velocity of the stairwell flow path resulted in a high rate of convective energy transfer to the structural firefighting gear and high perceived temperatures as the firefighters attempted to descend the stairs.

Firefighting crews flowed a hoseline down the stairs to combat the high temperatures; however no significant cooling was noticed by firefighters because the hose stream could not reach the seat of the fully developed fire in the kitchen area.

The crews were simply cooling the ventilation flow path without cooling the source of the energy in the apartment.

It was not until a hose stream was directed through an exterior window and a portion of the fire was extinguished that gas temperatures and velocities began to decrease, allowing firefighters to make entry to the terrace apartment via the stairs.

Plan view of flow path and temperatures within the apartment. Note the location of the seat of the fire and the location of initial hose stream application down the stairs.

Figure 016

 

Photograph of hoselines being positioned at the stairwell entrance door and front window. Note the heavy smoke venting from all front openings in apartment T2. (Figure 017)

Figure 017 Alpha Side Entry Door

 

Figure 017  Hoselines being positioned at the stairwell entrance door and front window. Rapid Fire Progression Leading to Flashover of the Third LevelFlames extended upwards from the T2 apartment sliding door and ignited the rear balconies of the second and third level apartments above.
 
Fire on the second floor balcony extended into apartment A2 by failing the sliding glass door and igniting vertical plastic slat curtains that were suspended above.As crews searched within the second floor apartment, they noted seeing the burning curtains on the floor with flames extending to a nearby couch (containing polyurethane foam padding) adjacent to the sliding doorway.
 
The fire continued to grow unsuppressed and spread to a second couch as interior firefighting crews were engaged in rescuing two victims from the living room in the second floor apartment.Personnel stated that at this point fire conditions seemed to improve, suggesting that crews were making progress extinguishing the fire. (The first arriving attack crew reported that they were able to see apparatus lights through the sliding doors on Charlie side, which indicated to them that smoke and fire conditions were improving.)Truck 1, a tiller unit staffed by a Lieutenant, two Driver/Operators, and a Firefighter, arrived on side Alpha and immediately began search and rescue operations.
 
Windows on the second floor Alpha/Delta side apartment (Apt. A-2) were vented and ladders were thrown to gain access. T-8 arrived at the alley on side Charlie. E-1 extended a ground ladder to the third floor balcony on the Charlie/Bravo side of the structure (Apt. B-1), and made access to the apartment to search for additional victims.They noted fire venting from the first floor Charlie/Delta apartment (Apt. T-2) out of the sliding glass doors progressing upwards towards the balcony on the second floor.
 
Upon entering the apartment, they conducted a primary search and noted minimal heat with light smoke conditions.The crew accessed the hallway via the apartment entry door and noticed an increase in the temperature and the amount of smoke.They immediately closed the door and exited the apartment via the ground ladder.Upon exiting the apartment, E-1’s crew observed E-292 on the scene with a hand line extending into the apartment of origin, (first floor, Charlie/Delta side, Apt. T-2).
 
The officer on E-1 noted white smoke coming from the unit.Having already laid a supply line from the intersection of the alley and Deanwood Road, E-292’s crew extended a 1 ¾” hand line into the apartment of origin. Moderate fire conditions with zero visibility were encountered, and they reported feeling a great deal of heat on their knees as they crawled through the apartment.The Lieutenant and the Firefighter from Truck-1 entered Apartment A-2 via a second floor bedroom window (Alpha/Delta side) and began a search for additional victims. As they traversed the living room area they found an unconscious male resident (victim #2).
 
At 1836 hours, the Lieutenant notified Command via an urgent transmission that a victim had been located and they needed assistance with evacuation. The Lieutenant and Firefighter noted a small fire in the rear corner near the victim as they exited the room. The crew returned to the bedroom from which they had entered and closed the door behind them. Victim #2 was then evacuated from the apartment via a ground ladder through the bedroom window, and transferred to EMS personnel on side Alpha.
 
Figure 019 Flame extension and suppression efforts at the rear of the structure. Flames caused the second level glass slider to fail and ignite plastic curtains in the doorway located
 

Figure 019

 
 

The middle level apartment (A2) entrance door was opened by a second search crew around the same time as the second couch ignited, creating a ventilation flow path from the second floor balcony, through the apartment, and upwards into the stairwell (third floor). This flow path follows the same general route through the apartment and into the stairwell as was seen in the terrace level apartment below. Squad 303’s crew arrived on scene after the bulk of the fire in the terrace level apartment had been suppressed and appeared to be under control. The crew entered the front stairwell, which had minimal smoke up to the second level and the crew began to systematically search the building.

Squad 303’s crew proceeded to search two apartments before entering the third floor right side apartment to conduct a search, leaving the entrance door open. It should also be noted that carpeting impacted the bottom of the door and prevented the apartment entrance doors on the second and third levels from closing automatically. The entry doors had to be actively pushed closed to overcome the friction of the carpet.

 

Photo depicting building smoke and fire conditions around the arrival of Squad 303.

Note the lack of heavy smoke or fire in the stairwell or terrace level.

There is also no indication of the growing fire in the second (middle) level apartment.

 

 

 

When Squad 303’s crew of two firefighters entered the third level apartment (B2), smoke was banked about halfway down the walls with moderate visibility. The crew could clearly see the floor of the apartment without the need to crawl below the smoke layer to search. Squad 303’s crew was unaware of the flames spreading across the two couches in the second floor apartment below them. The crew split in order to search the apartment faster, with one firefighter searching the front bedrooms and the officer searching the kitchen and living room.

As flames in the second level began to rollover into the apartment entranceway, the smoke layer in the third level quickly dropped to the floor with a rapid increase in temperature. With Squad 303’s crew searching above, flames began to extend into the stairwell, supplied by sufficient ventilation flowing through the apartment. This combination of fuel, heat and oxygen rich fresh air resulted in a rapid increase in heat release rate and flashover of the second level apartment followed by full room involvement.

The open entrance doors on the second and third levels created a ventilation flow path through the second floor apartment, into the sealed stairwell and up through the third floor apartment directly above. The flames followed this flow path and extended from the second floor, through the stairwell and into the living room area of the third floor apartment. Flashover of the third floor occurred approximately 30 seconds after the second floor experienced flashover.

Figure 026 and 027

 

Rollover from the second level apartment into the stairwell.

 

 
 
Flames followed the ventilation flow path and extend into the third floor apartment, resulting in ignition of the couches just inside the doorway.

 

 

    

 

Command sounded the building evacuation tones as flames extended into the hallway and up to the third level apartment.

Two couches just inside the entrance door on the third level ignited, blocking the primary means of egress for both firefighters from Squad 303. Upon hearing the evacuation horns from the trucks, the second firefighter from Squad 303 (searching the front bedrooms) attempted to exit the apartment via the apartment entrance door, however he was blocked by flames in the living room and stairwell.

Trapped in the bedroom, the firefighter bailed out headfirst down a ground ladder on the front side from the third floor. Squad 303 officer’s means of egress through the apartment entrance door was also blocked by the flames in the living room and stairwell. There were no windows located in the rear of the apartment.

The only means of escape was the balcony slider, however the entire balcony was engulfed in flames from the fully involved apartment below. With both escape routes blocked by flames and experiencing extremely high heat conditions, Squad 303’s officer requested assistance and declared a MAYDAY from the rear of the third floor apartment.

Firefighters re-entered the structure to combat the fire and locate the trapped firefighter. The downed firefighter was eventually located on the third level just inside the sliding glass door and was removed to the rear balcony. The firefighter was then extricated in a stokes rescue basket down the aerial ladder of a truck located in the rear, where he was subsequently transported to the hospital.

Effects of Compartmentation on Fire Spread

The Post Incident Analysis Team requested that alternate modeling scenarios be conducted to explore the effects of compartmentation on fire spread throughout the building.

The team specifically wanted to know how the ventilation flow paths through the stairwell would differ if the second or third level apartment entry doors were shut after entering/leaving the apartments. Two alternate computer fire modeling scenarios were conducted.

The first alternative modeling run featured the exact same fire scenario, except the second (middle) level apartment door was closed after the last victim was removed from that apartment. The apartment entry doors from the stairwell were fire-rated doors constructed of solid wood.

  • As soon as the door is shut, the ventilation flow path through the apartment and up the stairwell is blocked.

 

Shutting the second level apartment door blocks the flow path and flame extension into the stairwell. 

Even with the third floor apartment door left open, the model indicates that the stairwell and third floor remain tenable for firefighters. Flames eventually extend from the third floor balcony into the apartment, however the escape routes through the stairwell and the front apartment windows are accessible.           

The model indicates that closing the second level apartment door prevents the flow of smoke, heat and other products of combustion from entering the stairwell, thus preventing flashover of the stairwell and the third level. As long as the second floor entry door remains shut, the model indicated that the conditions within the stairwell and third floor remain tenable for firefighters, even with the third floor apartment door open.

A second alternative modeling scenario was conducted where the third level entrance door was closed after crews made entry to search the apartment.The same fire conditions from the actual model were used.When the door remained closed, the outlet of the ventilation flow path was blocked at the top of the stairs. Without a complete flow path, there wasn’t sufficient oxygen flowing through the second floor apartment to support extended burning in the stairwell.

Consequently after flashover of the second floor, the flames in the stairwell only exist momentarily before consuming all available oxygen and becoming ventilation limited.The fire model indicated that temperatures within the third floor apartment stayed tenable for firefighters, even with a fully developed fire on the second floor and flames in the stairwell.

Flames would eventually extend up the rear balcony to the third level, however they would not block egress through the living room and front windows of the apartment.By closing the apartment door on the third floor and blocking the outlet for fire gases emanating from the second floor apartment, the third floor apartment remains tenable for firefighting crews and the temperatures only briefly spike in the stairwell before the fire becomes ventilation limited.The ventilation flow through the apartments results in an increased burning rate within both the second and third levels, as well as the stairwell.                     

Results of each modeling scenario describing extent of flame spread

Results of each modeling scenario describing extent of flame spread.

 
 
 
 
 
 
 
 
 
 
The Effects of Compartmentation on Fire Damage to the StructureThe impact of compartmentation on fire and smoke spread is evident by examining the post-fire damage throughout the structure. While other factors contributed to the relative fire damage, including fire department overhaul and relative apartment configuration, analyzing the damage to the building and the position of the apartment entry doors provides insight on the benefits of compartmentation.

By closing apartment unit entrance doors and interior hollow core doors, one can slow or even block the ventilation flow path through the structure, thus significantly reducing the rate of fire spread. The photos below represent the post-fire damage in all six apartments within the fire building. Four of the six apartment entry doors were open for the majority of the fire and the relative difference in damage is clearly evident.

Terrace level stairwell landing looking into T1 (left) and T2 (right) apartments.

 

Door Closed……Door Open

 

 

Using doors to compartmentalize and limit fire and smoke spread in a structure is not limited to fire-rated entrance doors. Interior hollow core doors also offer considerable protection for compartmentation purposes.

A search crew utilizing the Vent, Enter and Search (VES) technique through a front window used a hollow core bedroom door to isolate themselves from the developing fire in the living room of apartment A2.

As the crews removed the second victim from the living room to the bedroom, they shut the bedroom hollow core door behind them.

The living room soon experienced flashover followed by full room involvement, however the bedroom remained isolated from the heat and smoke for the duration of the fire. The photos below illustrate this effective use of compartmentation to protect firefighters during a search.

 
Controling the Doors during VES

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
SUMMARY:
While no fire model will exactly replicate a fire, this model provided insight on the route of fire spread, the rapid fire growth leading to flashover of the second and third level, and the benefits of compartmentation on slowing fire and smoke spread.
  • The unidirectional flow path up the stairs from the terrace level apartment resulted in a high rate of convective heat transfer to the firefighters initially attempting to descend the stairs, making attacking the seat of the fire very difficult.
  • The model then supported the fact that the main stairwell acted as an open channel for fire and smoke spread between the second and third levels, resulting in flashover of the third level in approximately 30 seconds after the second level.
  • This rapid fire growth leading to flashover is supported by photographs, witness statements and fireground audio.
  • The model was then utilized to explore the effects of compartmentation using apartment entrance doors.
  • The FDS model supported the scene observations and indicated that shutting the entrance doors blocked the flow of buoyancy driven fire gases through the structure, ultimately preventing fire extension to the third floor apartment via the stairwell.
  • The FDS model was utilized as part of the overall engineering analysis of this tragic fire and allowed for a better understanding of the events that led to the firefighter MAYDAY and subsequent Line of Duty Death.
  • The model was also used as an educational tool providing insight on potential methods of preventing similar tragedies in the future.
  • The results of this engineering analysis are intended to be reviewed by the Post Incident Analysis Team to assist in the creation of recommendations to mitigate the danger associated with future fire incidents.

References:

Adaptive Fireground Management for Company and Command Officers: FDIC 2012

No comments

 

Here’s a promo for the program; “Adaptive Fireground Management for Company and Command Officers”: that will be presented at the Fire Department Instructors Conference- FDIC on Thursday April 19, 2012 10:30 am in Wabash 2.  If you’re attending FDIC this year, plan to mark this program down as one of your stops. I look forward to meeting “youz guys”.

This class presents new insights into emerging concepts and methodologies related to the challenges that arise while fighting today’s structural fires today. Extreme fire behavior, building construction, and occupancy risk mandate new strategic, tactical, and operational modeling. Students will be introduced to a new integrated model that represents new methodologies for predictive risk management, command compression and resiliency, tactical patience, and five-star command theories. This program has direct relevancy to all operational levels and ranks with specific focus toward company- and command-level responsibilities. INTERMEDIATE

Adaptive Fireground Management-FDIC 2012

 I’ll be posting some of my picks for must see FDIC programs later along wth some highlights of other programs that should be on your radar screen.

Dont Forget:

  • Buildingsonfire Channel on Youtube (subscribe): HERE
  • Buildingsonfire: Facebook HERE

FDIC Where Leaders Come to Train

Second Alarm Apartment Fire, VA

No comments

Photo by Maxim Boldin

 
 
 
A second alarm fire occurred in a four-story apartment building in the 20500 block of Reserve Falls Terrace, Loudoun County, VA that took command of over 13 apartment units.
 
The fire was reported at 07:39 hours on Sunday morning November 20, 2011.
 
Arriving companies found heavy fire was coming from the building. Fire crews initiated an offensive attack but were forced to evacuate due to potential structural collapse considerations.
 
A second alarm was activated and a defensive attack was mounted until it was safe for crews to get back inside. Firefighters from Sterling, Lansdowne, Ashburn and Fairfax responded to the fire. Crews remained on the scene for several hours performing overhaul and checking for hot spots.
 
At least 13 units in the building were damaged, displacing over 26 occupants. There were no reported injuries.
 
 

Alpha Division Aerial View-Street Side

 

Bravo Division (note grade change from the Alpha to Charlie sides)

 

Fire Extension thru Roof at Bravo Division Charlie

 

Typical Interior Room Compartments

 
 

Typical Unit Floor Plans

 
 
 
Links
 

 

Operational Considerations at Garden Apartment Complex and Residencies

 Fire ground operations at Garden Apartment Complex and Multiple Occupancy Residencies require due diligence and well-coordinated multiple company operations that have well established operating protocols, clearly defined ( but flexible) company and response duties and an effective and well-practiced and experienced cadre of company and command officers.  

Due to the likely demands and complexities of evolving and expanding incident conditions at fire involving Garden Apartment type buildings and complexes, couple with the civilian life safety concerns due to occupancy density and numbers, immediate and timely resources are necessary to conduct multiple and concurrent functional assignments that demand effectiveness, efficiency and trained company compositions.

Strategy and Tactics at Garden Apartment Complex and Residencies required special instructions, insights and knowledge that goes well beyond the practices and methodologies typically deployed at single family residential fire incidents.

Multiple occupancy dwelling units, occupancy loads, multiple floors, building construction, structural systems and assemblies, construction and material, methods of construction and building and occupancy layouts and configurations results in fast spreading and extreme fire conditions, common avenues for internal and exterior fire travel, congested travel paths and access/egress points, multiple hose line deployment strategies with adequate fire flows, effective building laddering, forcible entry support and concurrent, mobile and skilled search and rescue  capabilities.

The ability to deploy and operate multiple hand lines is mission critical at fires in these multiple occupancy dwellings. As are a number of other strategic and tactical functions; but again, If the fire is controlled and goes out- all the other escalating, concurrent and immediate demands, needs and requests along with highest risk factors for survivability to occupants and firefighter alike diminishes rapidly and can be managed.

 Here are some discussion points to chat about around the kitchen table;

  • Are your engine companies effectively set up and outfitted to stretch out and deploy extended lines, multiple lines on common floors or within various floor elevations?
  • Have you and your company practiced coordinated multiple company search and rescue protocols for multiple occupancy floor areas?
  • Have you considered the needs, impacts and operational deployment for a RIT on a common floor during extreme fire conditions that required interior common hallway access and extraction of a firefighter in distress or incapacitated?
  • Do you have the capability to deploy and implement multiple companies for coordinated roof ventilation operations?  IF so, have they training together in the past?
  • How effective and knowledgably are you and your company in initiating and completing multiple trench, strip or louver roof ventilation cuts?
  • Are you aware of the signs for potential or imminent collapse for the various types of garden apartment buildings in your response area? Did you know there are different considerations based on the vintage, age and construction systems and assemblies utilized?
  • When was the last time you either pre-fire planned any of your garden apartment building or complexes? Or did a company walk-through?
  • Which ones are protected by a fixed sprinkler system?
  • Do you what the water fire flow capabilities are for the hydrants and system in any of these garden apartment building or complexes?
  • Have you done any table top exercises considering a standard alarm assignment fire, or an escalating multiple alarms incident?
  • Do you consider occupancy risk versus occupany type for the buildings you respond to?
  • Are your considering the effects of extreme fire behavior and the potential for wind driven fire conditions in your IAPs?
  • Are you considering the collapse and compromise potential for floor and roof assemblies in your assignments?
  • Are you fully prepared for immediate or multiple RIT needs and deployments?
  • Do you understand how these garden apartment buildings are constructed, configured and will impact your strategic and tactical assignments?
  • Do you have the right skill set for performing safely and effectively in your assigned role and responsibilities? If not, what are you going to do about that gap?

 

Tactical Operations and Combat Fire Engagement with Go >Forward Training

No comments

 

Predictability of Performance and The NROE

 
Are you making plans to attend the newest premiere training conference, offering the latests in integrated eMedia, interactive classroom and hands-on training, education and networking? The Buildingsonfire.com family ( consistings of CommandSafety.com, TheCompanyOfficer.com, Taking it to the Streets Radio and Buildingsonfire.com) will be presenting two cutting edge and timely programs at both the Gateway Midwest Fire and leadership Training Conference on   

October 21 – 23, 2011 | St. Charles, MO  and the
November 4 – 6, 2011 | King of Prussia, PA

 

Dynamic Programs, Leading Instructors, Interactive, Dynanic and Social

 

Tactical Ops and the New Rules of Combat Fire Engagement

This session will present the new rules of combat structural fire engagement and provide insights into integrated command and operational risk management, tactical safety and tactical protocols based on occupancy risks versus occupancy type. Building and occupancy profiling requires knowledge of emerging construction methods, features, systems and components. Coupled with the increasing commonality of extreme fire behavior and the increased fire load package, these factors require new skill sets in reading the building and implementing predictive occupancy profiling to determine appropriate tactics for firefighters, company and command officers.

The class will examine case studies, history-repeating events, the latest testing and research findings on vent path theory, fire behavior, structural system integrity, wind driven fire theory and fire suppression theory, and engage students through interactive exercises and group discussions.

 

Reading the Building: Predictive Occupancy Profiling

Presented by Christopher J. Naum
Chief of Training, Command Institute, DC

And John Shafer
Lieutenant and Training Officer, Greencastle (IN) Fire Department

Today’s buildings and occupancies continue to present unique challenges to command and operating companies during combat structural fire engagement. Building and occupancy profiling, identifying occupancy risk versus occupancy type, emerging construction methods, features, systems and components coupled with the increasing commonality of extreme fire behavior and the increased fire load package require new skill sets in reading the building and implementing predictive occupancy profiling for firefighters, company and command officers. Integral to the presentation will be detailed discussions on building and structural system placarding methods and labeling programs.

 

Hands-On Training, Leadership/Strategy Workshops, Inspiring Education & Networking in the Midwest

Hands-On Training, Leadership/Strategy Workshops, Inspiring Education & Networking in the Midwest

October 21 – 23, 2011 | St. Charles, MO

Three packed days of top-notch education on leadership, strategy/tactics & professional growth with big name and fresh faces, multiple hands-on training by Brotherhood Instructors, pre-conference workshops featuring Tim Sendelbach & Rich Gasaway, social & networking events, inspiring keynotes, open discussions and more.

 

Hands-On Training, Leadership/Strategy Workshops, Inspiring Education & Networking in the East

Hands-On Training, Leadership/Strategy Workshops, Inspiring Education & Networking in the East

November 4 – 6, 2011 | King of Prussia, PA

Three packed days of top-notch education on leadership, strategy/tactics & professional growth with big name and fresh faces, multiple hands-on training by Brotherhood Instructors, pre-conference workshops featuring Alan Brunacini, Dennis Rubin & Rich Gasaway, social & networking events, inspiring keynotes, open discussions and more.

 
 
 Check out the podcast program on the New Fire Ground on Taking it to the Streets
 
 
 Take a run over to FirefighterNetcast.com and Taking it to the Streets and download the recent program that provided and insightful look and discussion of the New Fire Groundand the issues affecting the First-Due Officer and Command…which was hosted by our own Christopher Naum and two nationally renowned and highly regarded fire officers, instructors and innovators.Both Divison Chief Ed Hadfield (CA) and Deputy Chief Jason Hoevelmann (MO) are speakers at the Gateway Midwest Fire & Leadership Training Conference brought to you by Go Forward Training and coming to the St. Charles/St.Louis, Missouri metro area on October 21-23. 2011.

  • Conference Direct Link HERE.
  • Go Forward Training HERE
 
Taking it to the StreetsTM is a monthly radio show featured on BlogTalk Radio and is hosted by nationally renowned fire service leader Christopher Naum, a 36-year fire service veteran and highly regarded national instructor, author, lecturer and fire officer and the distinguished leading national authority on building construction and fire ground operations. Taking it to the StreetsTM is a Buildingsonfire.com Series and FireFighternetcast.com Production, © 2011 All Rights ReservedCheck out the latest downloads of recent programs in the archives by visiting Taking it to the Street’s webpage on Firefighternetcast.com or for program insights at CommandSafety.com.

  • Tune in to the Program Wednesday evening August 17th at 9:00 pm ET, HERE
  • Firefighternetcast.com HERE
  • Taking it to the Streets Radio Programs, HERE and HERE
  • Buildingsonfire.com, HERE

FDNY Chief Joseph Pfeifer on Leadership During 9-11

No comments

Ten years ago, on September 11, 2001, New York City Fire Department Battalion Chief Joseph Pfeifer saw the first aircraft hit the North Tower and radioed the alarm, the first FDNY fire chief to take command.

Today, Pfeifer is the New York City Fire Department’s Chief of Counterterrorism and Emergency Preparedness and a Citywide Command Chief. Wharton management professor Michael Useem talked with Pfeifer recently about his leadership during the 9/11 rescue efforts and what the New York City Fire Department and other cities are doing to prepare for the unexpected. This was originally posted on Firefighternation.com, HERE. For a Complete overview and remembrance on this tenth anniversary of 9|11, go HERE at FFN

 

 
 
 

 

Ten Minutes in the Street: The First-Due

No comments

Ten Minutes in the Street with Christopher Naum

First-due company operations have a wide variation of considerations and demands that must be readily identified, rapidly assessed and effectively acted upon through concise and direct orders. 

 

 Arrivals and subsequent deployments during night time periods pose ever increasing challenges to arriving officers in the ability to ascertain and recognize factors that will have a direct or ancillary affect in the developing incident action plan, tactics and task assignments.

 

Night time operations at structure fires, especially those with heavy fire involvement upon arrival can mask or conceal critical operational or safety considerations, developing or progressing smoke conditions that may be missed due to darkness as well as other occupancy risk profiling considerations or civilians in distress or entrapment.  

  

Rapidly escalating or deteriorating conditions coupled with conflicting or concurrent operational demands (rescue and suppression) with limitations imposed due to staffing levels further exasperates the need for the company or command officer to maintain acute situational awareness, implement effective scene scanning , recon, the 360 and assimilate all available information and presumptions that can be made into orders and assignments.

 

This edition of Ten Minutes in the Street TM is looking at the considerations for the first-due engine company upon arrival at a well involved single family residential house fire. Take a look at the physical layout and arrangement of the incident scene and the primary house fire and exposures.

 

Take some time to look at the accompanying video clip. The video clip was compliments of our good friend FF David Stacy an intern with the IAFC and a member of College Park Station 12 (MD).

This scenario makes use of [the] fireground video clip and subsequent pictorials for representive example purposes only and are not intended to recreate or critique the events depicted in this video or in the operations shown.

 

Here are some considerations to talk and discuss in a group setting. Deliberate and debate the operational issues, roles and responsibilities, safety considerations, as well as tactical deployment demands and incident priorities.  Address through your discussions the requirements that are imposed upon your selected or suggested actions based on your company, departments or agency SOP/SOG or expectations.

 

You can discuss this event using the following criteria in any combination;

 

Building:              Single Family Residential, two stories

Profile:                 Built: 1986, wood frame with some engineered structural floor components, wood siding, full basement

Size:                      1,764 square feet, three bedroom, 2.5 baths, large sun room and pool on Division 3

Occupancy:         Occupied at the time of fire discovery

District:               (You select) Fully hydrant water supply or limited

 

Deployment:    

  •  Arrival with Engine and Truck Company: Staffing four each
  •  Arrival with Engine Company only with staffing of four (or based upon your staffing levels)
  •  Arrival with two Engine companies: Staffing based upon your staffing levels

 

 

Street Side from the curb (Google Street View)Division Alpha view

 

   

 

  

 

 

Discussion Points and Questions;

  • What are the immediate priorities and operational considerations?
  • What are the primary considerations that the company officer must consider and why?
  • What factors must be identified and considered in order to implement your IAP?
  • What can be expected as the incident progresses in the next ten minutes of elapsed time?
  • What is the Building and Occupancy Profile?
  • Should a 360 be implemented:  if so why and by whom?
  • What is mission critical upon arrival at a well involved structure fire especially when it involves a residential structure at night?
  • What impact on tactical operations will time of night have on the IAP?
  • Based upon your staffing levels what can be realistically assigned? Why?
  • Identify some of the operational safety concerns evident or assumed that must be recognized and considered?
  • What affect will the building structure and degree of fire involvement have on incident operations?
  • What are the expected (sustained) fire flow rates that will be required?
  • What are the resource needs; now or later?
  • What should be considered if there are escalating exposure issues or extension?

Download the PDF File Version for use around the Kitchen Table, a drill or as a Training Aide: http://thecompanyofficer.com/files/2011/08/Vol11NO8.pdf

 

These are but a few questions that can be posed, think about other questions or considerations based upon local operational considerations, risk, or limitations.

 

 

Tonight on Taking it to the Streets: The New Fire Ground and the First-Due

No comments

Tonight on Firefighternetcast.com; Taking it to the Streets-The New Fire Ground and the First-Due

The New Fire Ground and the First-Due

Join in tonight at 9pm ET for another special and exciting program continuing our series discussion on the Emerging Tactical Renaissance in the Fire Service.

Taking it to the StreetsTM, radio program hosted by highly regarded national instructor, author, lecturer and fire officer Christopher Naum, continues to provide provocative insights and dynamic discussions with leading national fire service leaders and guests on important issues affecting the American Fire Service with applications internationally within the tradition and brotherhood of the Fire Service.
This edition of Taking it to the StreetsTM the program will be looking at the New Fire Ground and the First-Due
Joining the program will be two special guests: Division Chief Ed Hadfield (CA) and Deputy Chief Jason Hoevelmann (MO) providing a great opportunity to listen to perspectives from coast to coast and the heartland.

Join in on what is certainly going to be an insightful look and discussion of the New Fire Ground and the issues affecting the First-Due Officer and Command…

Both Divison Chief Ed Hadfield (CA) and Deputy Chief Jason Hoevelmann (MO) are speakers at the Gateway Midwest Fire & Leadership Training Conference brought to you by Go Forward Training and coming to the St. Charles/St.Louis, Missouri metro area on October 21-23. 2011. I also have the honor of lecturing and presenting two programs, one of which one will be co-presented with my good friend and colleague Lt. John Shafer. (The GreenMaltese.com HERE)

  • Conference Direct Link HERE.
  • Go Forward Training HERE

Incorporating and facilitating the latest training delivery concepts and methodologies and integrating current and emerging technology, social media platforms, eMedia and internet based content management material in order to provide unparalleled fire service curricula, training and education, The Command Institute, Buildingsonfire.com and Fire Fighternetcast.com will be integrating content across a number of platforms to provide you with supportive information and training that will ultimately integrate with the direct training deliveries at the conference.

This segment of Taking it to the Streets on FirefighterNetcast.com is the first step in achieving that goal and process. Look for more integrated materials, exercises and eMedia on CommandSafety.com, TheCompanyOfficer.com and Buildingsonfire.com

Grab a cup of coffee and sit down for a special one hour program with Taking it to the Streets on FirefighterNetcast.com where we’ll be discussing developing concepts, methodologies and operational perspectives affecting today’s emerging and evolving fire ground and the new considerations for the First-Due with Christopher Naum and fire service leaders, Division Chief Ed Hadfield and Deputy Chief Jason Hoevelmann.

Join in on the live open discussion with other fire service personnel from around the country.

Taking it to the StreetsTM is a monthly radio show featured on BlogTalk Radio and is hosted by nationally renowned fire service leader Christopher Naum, a 36-year fire service veteran and highly regarded national instructor, author, lecturer and fire officer and the distinguished leading national authority on building construction and fire ground operations. Taking it to the StreetsTM is a Buildingsonfire.com Series and FireFighternetcast.com Production, © 2011 All Rights Reserved

Check out the latest downloads of recent programs in the archives by visiting Taking it to the Street’s webpage on Firefighternetcast.com or for program insights at CommandSafety.com.

  • Tune in to the Program Wednesday evening August 17th at 9:00 pm ET, HERE
  • Firefighternetcast.com HERE
  • Taking it to the Streets Radio Programs, HERE and HERE
  • Buildingsonfire.com, HERE

Gateway Midwest Fire & Leadership Training Conference

Gateway Midwest

Gateway Midwest

October 21 – 23, 2011 | St. Charles, Missouri
Join Us at Our Inaugural Event!
Featuring three packed days of hands-on training, top notch education with big names and fresh faces, pre-conference workshops, social events, open discussions and more.

Liberty Regional

Liberty Regional

November 4-6, 2011 | King of Prussia, PA
Three days of top notch hands-on training, a comprehensive educational program featuring top names and fresh faces, pre-conference workshops, social events, open discussions and more.

JEMS Seminar Series

JEMS Seminar Series

October 21-23, 2011 | St. Charles, Missouri
Bringing the Best in EMS Education to Your Region
We know budgets are tight, we know it can be tough to get approval to attend a conference out of state. The JEMS Seminar Series brings high-quality, high-impact EMS speakers right to you.
Learn, Network, Share & Save!

Deployment Decisions: Defining Operations on the First-Due

No comments

First-due company operations are influenced by a number of parameters and factors; some deliberate and dictated, others prescribed and prearranged and yet others subjective, biased, predisposed or at times accidental, casual and emotional. For many of you riding the seat or arriving assuming command; you understand the connotations and implications I’m making here.

Here’s an excellent discussion and debate point to bring up, when time permits today or this evening with your company or personnel; one that leads to a multitude of viewpoints, opinions and divisions.

On the first-due; what are the three or four key parameters when confronted with arrival indications of a fire within a structure that define your deployment and transition into operations?

Now, before everyone gets worked up; we all realize there are numerous variables affecting key decision-points that must be recognized, imputed, synthesized , analyzed and decisions made, assignments formulated and the task deployed; this list can be long – very long.

However, giving a building and occupancy with indications of a fire within, what has your experience provided you with the KEY influencing parameters? Are there key factors, or are there “lists” of factors based upon yet another “list” of conditions. The question is rhetorical the answeres are not.

Is it occupancy type, occupancy risk, fire behavior or fire dynamics, time, risk, communicated information, past performance factors (experience), presumed or known life hazards, predicated building or system performance, crew KSA sets or other factors, etc? Does naturalistic or RPDM decision-making influence; is the deployment tactically driven or predisposed by SOP, SOG or personal attributes and biases? Safety Conscious or aggressively driven? You get the picture…..

Try to distill them down to three or four mission critical key issues (if you can). This is a great exercise to see what everyone else considers the key factors to be or should be when deploying and  going into operations; sometimes it’s more complex than just “pulling the line” or getting in….

Take the time to use some critical thinking and don’t be subjective….think about the responses and ask why?

Building Knowledge=Fire Fighter Safety

No comments

What is YOUR level of Knowledge?

Modern incident demands on the fireground are unlike those of the recent past requiring incident commanders and commanding officers to have increased technical knowledge of building construction with a heightened sensitivity to fire behavior, a focus on operational structural stability and considerations related to occupancy risk versus the occupancy type.  

Strategies and tactics must be based on occupancy risk, not occupancy type, and must have the combined adequacy of sufficient staffing, fire flow and tactical patience orchestrated in a manner that identifies with the fire profiling, predictability of the occupancy profile and accounts for presumptive fire behavior.  

Building Knowledge = Fire Fighter Safety….where do you fit into this equation?

Christopher Naum, SFPE, 2011

 

Know Your World

 

Another Multiple Alarm Fire in Camden, NJ

No comments

An Eight Alarm Fire Hit Camden on Saturday morning

A huge fire early this morning has engulfed a three-story warehouse in downtown Camden, two days after another massive blaze in the city. The Camden County Fire dispatch office says about 20 fire companies were  fighting the eight-alarm blaze at the Howland Croft and Sons warehouse in the 400 block of Winslow Street. There have been no reports of any injuries. Firefighters took the call on the fire at 2:24 a.m. Saturday. The building  takes up a large part of a block on Winslow Street. Reports are the fire was brought under control at about 6 a.m. Thursday’s 12-alarm fire leveled an abandoned tire business and most of the two surrounding city blocks, leaving about 50 people homeless.

Photo by Ted Aurig

  • Eight Alarm Fire in Camden Saturday morning Photo gallery, HERE
  • PhillyFireNews.com Photo Coverage HERE

 

 

12-alarm Camden inferno: http://www.courierpostonline.com/apps/pbcs.dll/gallery?Avis=BZ&Dato=20110609&Kategori=NEWS01&Lopenr=106090805&Ref=PH

Related Links
  • Union: More staff could have helped contain fire
  • Camden warehouse owner is delinquent on taxes
  • Fire Aftermath
  • FDNY Medal Day 2011

    No comments

    2011 FDNY Medal Day FDNY Photo

    FDNY celebrated the valor of its members during Medal Day 2011, which took place at the Intrepid Sea, Air and Space Museum on June 8.

    “This is one of the most wonderful days of the year,” said Mayor Michael Bloomberg. “We’re celebrating those who put themselves in harms way to protect others.”

    The event honored eight fire officers, one EMS officer, one fire marshal, 27 firefighters, two paramedics, seven emergency medical technicians and four fire companies.

    Members of Engine 54 and Ladder 4 received the 2011 World Trade Center Memorial Medal for their response to the would-be Times Square car bomb on May 1, 2010. Learn more

    This year’s James Gordon Bennett Medal winner, the highest honor for a member of the Fire Service, was Firefighter Peter Demontreux from Ladder 132. He saved two victims from a burning brownstone in Brooklyn on Aug. 30, 2010. Learn more

    James Gordon Bennett Medal winner, Firefighter Peter Demontreux L132

    From the NYC.GOV FDNY Site Posting from 2010 (HERE)

    Firefighters Rescue Three from Dramatic Early Morning Fire

    The brownstone at 175 Putnam Ave. in Bedford-Stuyvesant, Brooklyn, where three people were rescued by FDNY firefighters on Aug. 30.
    The brownstone at 175 Putnam Ave. in Bedford-Stuyvesant, Brooklyn, where three people were rescued by FDNY firefighters on Aug. 30.

    In a series of dramatic early morning rescues Aug. 30 in Brooklyn’s Bedford-Stuyvesant neighborhood, firefighters pulled several residents from the top floors of a burning brownstone, with one firefighter walking through flames and suffering second-degree burns to help someone trapped inside.

    “We walked through a room that was engulfed in fire,” said Firefighter Peter Demontreux of Ladder 132, recalling how he helped a civilian to safety. “We were on fire.”

    The fire broke out shortly before 4:30 a.m. at 175 Putnam Ave. and quickly escalated to a second-alarm.

    Firefighter Demontreux, who was assigned to the Outside Vent position, immediately climbed up the aerial ladder upon arrival to rescue a man hanging from the third-floor front window, who told him that there was another person still inside.

    He donned his mask and went inside to begin his search, but thick black smoke made it impossible to see.  He returned to the window, where Firefighter Richard Myers of Rescue 2 offered to begin breaking out windows on the third floor to increase visibility. 

    Demontreux went back in.

    “I heard a man at the back and searched along the wall, following it to the rear, where I found the second occupant hanging out the back window trying to breathe,” Firefighter Demontreux said.

    FF Richard Myers of Rescue 2, Deputy Chief Robert Strong of Division 11, FF Peter Demontreux of Ladder 132 and FF Charles Dodenhoff of Rescue 2.
    FF Richard Myers of Rescue 2, Deputy Chief Robert Strong of Division 11, FF Peter Demontreux of Ladder 132 and FF Charles Dodenhoff of Rescue 2.

    Helping the man along toward the front of the building, they passed through a room now fully involved, but knew it was their only means left of escape.

    “I just wanted to get out of there as fast as possible,” Firefighter Demontreux said.

    Outside of the building, with Firefighter Demontreux gone for several minutes as flames intensified inside, Firefighter Myers feared the worst.  “I was about to give an urgent, a mayday,” he said. “All of a sudden there’s Pete, running out and he and the civilian are on fire.”

    Firefighters with a charged hoseline down below quickly turned the water on Firefighter Demontreux and the victim, putting out the flames on their clothes and bodies.

    “I thought Pete was dead,” Firefighter Myers said. “Incredible, just incredible job that he did.”

    Members of Rescue 2 also performed heroically, using a life-saving rope to rescue a man from the third floor of the building.  Firefighter Charlie Dodenhoff used the rope to pull a man out of a third floor window.

    In all, four firefighters were injured in the fire, with Firefighter Demontreux suffering burns on his face and back.  He was treated and released from an area hospital Monday.  Three civilians also suffered critical injuries and were taken to area hospitals.

    Fire marshals are still investigating the cause of the fire, but it is considered suspicious.

     

    FDNY Medal Day 2011 Booklet  FDNY Medal Day 2011 Book Final June 8 2011

    2011 FDNY Medals Stand FDNY Photo

    SFFD Firefighter Memorials and Updates

    No comments

    More details emerged Monday about last week’s fatal Diamond Heights blaze, as fire officials said an emergency alert accidentally went off on a nearby fire engine about the same time two firefighters’ personal alarms sounded inside the burning building according to published reports.

    Lt. Vincent Perez, 48, and firefighter-paramedic Anthony Valerio, 53, of Engine Company 26 both died from injuries they suffered while battling a blaze at a four-story home at 133 Berkeley Way on Thursday morning.

    While fighting the fire, one or both of Valerio and Perez’s personal alert safety system devices went off.  Around the same time, a firefighter on Engine Company 20 — which had yet to arrive on the scene — had inadvertently hit the emergency button on the engine.

    Firefighter memorials

    A joint funeral for fire Lt. Vincent Perez and firefighter-paramedic Anthony Valerio will be held at 12:30 p.m. Friday at St. Mary’s Cathedral, 1111 Gough St. in San Francisco. A vigil for the two men will be held at 7 p.m. Thursday, also at St. Mary’s.

    San Francisco Fire Fighters Local 798 has established trust accounts at the San Francisco Fire Credit Union for the families of Perez and Valerio. Donations can be made to SFFCU, 3201 California St., San Francisco, CA 94118.

    Condolence messages can be sent to Fire Station 26, 80 Digby St., San Francisco, CA 94131.

    San Francisco FD mourns the loss of a Second Firefighter LODD After Diamond Heights Fire

    No comments

    

    SFFD Firefighter Anthony Valerio

    It’s being reported that San Francisco Fire Fighter Anthony Valerio passed away this morning as a result of injuries sustained while operating the Diamond Heights fire on Thursday June 2nd. This becomes the second line of duty death from this incident that also resulted in the LODD of Lt. Vincent Perez. Anthony “Tony” Valerio, a 53-year-old firefighter and paramedic critically injured in the Thursday blaze, died at San Francisco General Hospital at about 7:40 a.m., city officials said.

    Read more: http://www.sfgate.com/cgi-bin/article.cgi?f=/c/a/2011/06/04/BA2F1JPNS2.DTL#ixzz1OKjGjnNs

    San Francisco firefighter Anthony Valerio is the second firefighter to die from Thursday’s Diamond Heights fire. According to San Francisco Fire Chief Joanne Hayes-White, Valerio had “significant damage to his respiratory system” and burns across his body after Thursday’s fire. Valerio has burns to 12 percent of his body.

    WKGO TV ABC7 reports that according to San Francisco Fire Deputy Chief Mike Gardner said most of Fire Fighter Valerio’s burns were from steam and not from fire, adding that the temperature inside the structure was between 500 and 700 degrees.

    Previous Coverage, HERE, HERE and HERE

    • Logs show desperate hunt for doomed SF firefighters, HERE
    • 

    Read more: http://www.sfgate.com/cgi-bin/article.cgi?f=/c/a/2011/06/03/BAJG1JPBKV.DTL#ixzz1OKn7vgot

    Updated Sunday June 5

      

    San Francisco’s fire chief says this is the first time in her 21 years with the department that two firefighters have died in the same fire.

    Slowly and silently, Valerio’s body was wheeled to an awaiting van; the silence finally broken by the rain and his family’s tears. The pain hung in the air outside San Francisco General Hospital – a place that became a gathering spot for the hopeful. Valerio’s family and friends had been there around the clock since Thursday. Valerio and Perez were rushed to the hospital after the two were found unresponsive inside a burning house in Diamond Heights – a sudden blast knocked them down. Perez died late Thursday. From Reports published by WKGO-TV ABC 7 ; “It is particularly difficult, you’re mourning the loss of one and then to have another one very close from the same fire is challenging,” said San Francisco Fire Chief Joanne Hayes-White.

    Saturday was the first time Valerio’s doctors gave details about the uphill battle the 53-year-old faced – including the fact that he was in cardiac arrest the moment he arrived at SF General.

    “Between all the injuries he had from the initial blast, the smoke inhalation, the fact that he had a really bad lung injury, which was precipitated by what happened on the scene, but we try to do everything we can,” said SF General Hospital Dr. Andre Campbell.

    But in the end it wasn’t enough. On this day, the firefighter’s two families, his work family at Station 26 and his immediate family – realized Valerio’s 40 hour long fight to survive was over.

    The fire department and the families have agreed to have a joint funeral for both Tony Valerio and Lt. Perez on Friday at Saint Mary’s Cathedral.

    Lt. Vincent Perez, San Francisco FD
    Firefighter Anthony Valerio  

      

    From Thursday

    Previous postings from Commandsafety.com;

    Courtesy Patty Stanton

    Courtesy Patty Stanton

    Courtesy Patty Stanton

    Updates from San Francisco;

    Charlie Side

    Charlie Side, Fire Extending

    Alpha Street Side from Google Streets

    Aerial Charlie Side

    Coincidentially, we posted a remembrance to the DCFD Cherry Road Townhouse Fire and Double FireFighter LODD from May, 1999 that is worth another look as it has similar connotations related to fire behavior, flashover conditions and multiple floor level construction factors during initial fire suppression operations, HERE

    Don’t Count on Mutual Aid: “Let it Burn”

    No comments

    From the Grand Rapids Press Series

    Interesting discussions and dialog coming from the Grand Rapids Press and a series of articles on fire service delivery , capabilities, ratings and finances. The Series was written by Jim Harger a reporter for the Grand Rapids Press. An examination and comparison of staffing levels, training, service delivery and budgets was presented. Budget issues, efficiencies and operations seem to be the issues.

    The SERIES on mlive.com/grand-rapids:

    SUNDAY: Who’s in your fire department? Some communities have full-time firefighters on duty around the clock, while others rely on paid-on-call volunteers.

    MONDAY: What does the future hold? Grand Rapids is looking at new methods and mergers with neighbors as it prepares to cut $3 million a year in costs.

    TUESDAY: How safe is your neighborhood? We list the insurance industry ratings for each of the 50 Kent and Ottawa county fire departments.

    An excerpt from the Grand Rapids Press, accessed (HERE) on June 2, 2011;

    City Manager Greg Sundstrom said he’s getting tired of having his firefighters put out fires in the neighboring suburb of Grand Rapids Township.“Just know that if you buy a house in Grand Rapids Township and it starts on fire, say goodbye. That’s how it is,” said Sundstrom in remarks to city commissioners Tuesday.

    Sundstrom was commenting in the wake of a Grand Rapids Press series that highlighted the differences between urban, suburban and rural fire departments. The series highlighted a May 5 Grand Rapids Township house fire in which Grand Rapids firefighters were called to assist.

    Then there’s another quote from the City Manager on another issue HERE and a grant issue HERE

    Faced with making cuts in the city’s 203-person fire department’s $29 million budget, Sundstrom said he resents being lectured by township officials about the examples they set of fiscal prudence.

    What makes this such an intriguing series and article is the follow-up that the has the Grand Rapids city manager lashing out over the fire department being called to help neighboring township. (HERE).

    Manager Greg Sundstrom said he doesn't need lectures from neighboring communities. Grand Rapids Press File PhotoCity

     
     
    Direct Links to the Series below;
     
     
    How does your township fire department rate? See our map with safety ratings
     
    Here’s a link to the city manager’s reaction:
     
     
    This story also surfaced during the newspaper’s  investigation:
     
     
    One has to wonder if the right people have read any of the following reports, studies or publications or if they have the “right stuff”on their radar screens…(see Commandsafety.com HERE;
     

    Combat Ready and the Fire Service Warrior on Taking it to the Streets

    No comments

    Taking it to the Streets with Christopher Naum

    Join in on Tuesday May 17th at 9pm ET for another special and exciting program continuing our series discussion on the Emerging Tactical Renaissance in the Fire Service.

    Taking it to the StreetsTM, radio program hosted by highly regarded national instructor, author, lecturer and fire officer Christopher Naum, continues to provide provocative insights and dynamic discussions with leading national fire service leaders and guests on important issues affecting the American Fire Service with applications internationally within the tradition and brotherhood of the Fire Service.
    This edition of Taking it to the StreetsTM the program is all about being COMBAT READY and THE FIRE SERVICE WARRIOR
    Joining the program will be special guest, Christopher Brennan the author of The Combat Position: Achieving Firefighter Readiness, published by PennWell Books and the author of the notable blogsite, The Fire Service Warrior.

    Christopher Brennan

    Christopher Brennan is a firefighter in the suburbs outside Chicago; a field instructor for the Illinois Fire Service Institute; and a consultant for local, state, and federal agencies.

    He joined the fire service in 1997 as a paid-on-call member of the Calumet Park (IL) Fire Department.

    During his career, Chris has worked for the Calumet Park Fire Department, part-time for the Darien-Woodridge (IL) Fire Protection District, and as a career firefighter and engineer with the Harvey (IL) Fire Department.Chris is an active instructor teaching for the Illinois Fire Service Institute, has taught terrorism response training overseas, and has been an instructor for FDIC.

    He is a member of the International Association of Fire Fighters, the International Society of Fire Service Instructors, and the Illinois Society of Fire Service Instructors.

    He is also the author of numerous articles for fire service magazines, including Fire Engineering.

    Join in on what is certainly going to be an insightful look and discussion of the path of the fire service warrior.

    Discussions on what is meant by embracing the philosophy of the fire service warrior, and striving for the ready position—the synthesis of physical and mental readiness that allows for suggested optimum fireground performance— and its potential application towards reducing firefighter injuries and fatalities

    We’ll further explore how as Christopher Brennan states; “Today’s firefighter must be a warrior who will unflinchingly put his very life in harm’s way to accomplish a mission, but who is also fully informed about the path being chosen”.

    LINKS

    • Surviving on the Fireground: Chris Brennan Talks Situational Awareness at FDIC 2011, HERE
    • A Culture of Excellence – Christopher Brennan , HERE
    • The Fire Service Warrior Blog, HERE

    The Combat Position

    The Combat Position: Achieving Firefighter Readiness, PennWell Books, HERE

    Firefighting is combat and should be viewed as a warrior’s calling.

    Firefighters put themselves in harm’s way to protect others, a selflessness rooted in the same noble drive as the military warriors who defend our nation.

    This book about combat is meant to be a guide for those who seek to follow a warrior’s path, the path of the fire service warrior.

    Today’s firefighter must be a warrior who will unflinchingly put his very life in harm’s way to accomplish a mission, but who is also fully informed about the path being chosen.

    Embracing the philosophy of the fire service warrior, and striving for the ready position—the synthesis of physical and mental readiness that allows for optimum fireground performance—can reduce firefighter injuries and fatalities.

    The Combat Position: Achieving Firefighter Readiness will be an invaluable tool for firefighters, company officers, chief officers, and instructors.

     

    Grab a cup of coffee and sit down for a special one hour program with Taking it to the Streets on FirefighterNetcast.com where we’ll be discussing developing concepts, methodologies and operational perspectives affecting today’s emerging and evolving fire ground operation with Christopher Naum and this emerging fire service leader.

    Join in on the live open discussion with other fire service personnel from around the country.

    Taking it to the StreetsTM is a monthly radio show featured on BlogTalk Radio and is hosted by nationally renowned fire service leader Christopher Naum, a 36-year fire service veteran and highly regarded national instructor, author, lecturer and fire officer and the distinguished leading national authority on building construction and fire ground operations. Taking it to the StreetsTM is a Buildingsonfire.com Series and FireFighternetcast.com Production, © 2011 All Rights Reserved

    Check out the latest downloads of recent programs in the archives by visiting Taking it to the Street’s webpage on Firefighternetcast.com or for program insights at CommandSafety.com.

    • Tune in to the Program Tuesday evening May 17th at 9:00 pm ET, HERE
    • Firefighternetcast.com HERE
    • Taking it to the Streets Radio Programs, HERE and HERE
    • Buildingsonfire.com, HERE

    It’s Not Just a Job: Message to the Recruits

    No comments

    What it means to be a Fire Figher. It’s not just a job; responsiblilty , privilege- its the service, committment and the calling.

    Take a minute to listen to the Training Officer’s words to the recruits at the start of the training session….Where do you fall in?

    First-Due Residential Fire

    No comments

    Video Clip provided by PGFD Captain Greg Zalenski, Station 812 -College Park (MD)VFD.

    A mid-morning fire in a Single family (SFR) residential structure challenged arriving companies as they went into operations. A video clip depicting the responding fire chief enroute and arrival provides a good sequence of the events, fire severity and fire growth. The 2,074 square foot (SF) residential occupancy built in 1988 of wood frame construction did not have any immediate exposure concerns and was readily accessible for operating companies.

    Make this a training opportunity; Some things to think about….

    After reviewing the video, stills and aerials; as an arriving company or command officer-what some of the operational concerns you would have upon arrival with the volume of fire showing and progressing?

    • In this incident, a second alarm was transmitted as a precautionary measure.
    • How would you determine the need for additional resources?
    • How effective would your box alarm assignment be based upon your current deployment critera?
    • Would you have enough personnel and equipment to effectively and safely engage in combat fire suppression, search and rescue and support operations?
    • How would the dynamics of this event change- if there were reports of unaccounted civilians?
    • How would you defined the command or tactical risk profile of this evolving incident?
    • What concerns would you have related to the actual or suspected construction features? 
    • In the event of a collapse, compromise, entrappment or fire induced condition resulting in a firefighter mayday and need for RIT; what operational  considerations  would you need to consider, assign or implement?

    Incident Overview From PGFD NEWS; Mark E. Brady, Chief Spokesperson

    Firefighters from Beltsville (MD) and surrounding stations were alerted to a house fire in the 4100 block of Ulster Road on Monday April 11th morning just before 10:00 am.

    Fire/EMS units arrived within minutes and encountered heavy fire coming from the 2-story single family home with an attached garage. A precautionary 2nd Alarm was sounded as fire consumed the garage and had extended into the second floor and roof area.

    As firefighters were advancing hose lines and searching for any occupants inside the home, a roof collapse appeared imminent and all personnel were ordered to evacuate the structure. All firefighters self evacuated safely and the firefight continued from the safety of the exterior. Once the bulk of the fire had been knocked down, firefighters re-entered the structure to complete searches and extinguish the remainder of the fire. With the exception of a family pet dog, no one was home when firefighters arrived.

    It required about 40 minutes to extinguish the bulk of the fire. There were 60 firefighter/medics, command officers and support personnel that operated on the scene of this incident.

    The cause of the fire is under investigation and estimated fire loss is still being tabulated. An adult male neighbor sustained minor lacerations to his arm when he broke the window out of a rear door to allow a dog to escape from the burning home.

    Site Plan of the Residential Occupancy

     

    A-B Side

     

    Aerial A-D Side

     

    Photo By M. Brady, PGFD

     

    Photo By M. Brady, PGFD

    Related Posts with Thumbnails