Skip to content


Auto Parts Store Roof Collapse Double LODD 1996

No comments

Roof Collapse Chesapeake VA 1996 Double LODD

OVERVIEW

On March 18, 1996, two firefighters were killed in Chesapeake, Virginia when they became trapped by a rapidly spreading fire in an auto parts store and a pre-engineered wood truss roof assembly collapsed on them. The cause of the fire was an electrical short created when a power company truck working in the rear of the building drove away with its boom in an elevated position, accidentally pulling an electrical feed line from the main breaker panel at the rear of the store.

Post-incident investigations indicate that the electrical fault may have sparked multiple points of fire origin throughout the roof structure of the building, due to improperly grounded wiring. At the time of the report issuance, this was exemplified as another incident illustrating the rapid failure of lightweight construction systems when key support components are involved in a fire. The report pointed out the importance of prefire planning and accurate size up by fire companies to determine the risk factors associated with a fire in this type of construction.

Lessons regarding importance of initial company actions, constant re-evaluation of action plans, strong command and coordination of units on the fireground, and recognition of signs of impending structural failure were also reinforced.

Reading through any number of NIOSH, USFA or NFPA reports, similar issues, challenges and operational factors resonate and continue to shape and challenge today’s fire ground operations.

It is without exception that the knowledge and insights being gained by the continuing efforts from the UL and NIST Research Studies coupled with the recommendations, from the NIOSH Fire Fighter Fatality Investigation and Prevention Program (HERE) will provide increased awareness and understanding of buildings, fire dynamics and the effectives of fire within the compartment, building and the manner in which fire departments engage in fire suppression operations.

Today’s fire ground is changing at a very rapid pace as it relates to the continued evolution, transition of engineered structural components and systems (ESS).

Are you prepared, knowledgeable and understand that new strategic and tactical approaches are required?

One of the most significant actions initiated by the Chesapeake Fire Department was the implementation of a Truss Identification Program (TIP).

Take a look at a past posting on CommandSafety.com where we published on an overview a few years ago of truss and engineering component systems across the United States HERE.

City of Chesapeake (VA) Truss ID Program, HERE

The following are excerpts and narrative from the USFA Technical Report Series TR-087 and NIOSH Report 96-17

Aerail Overview on Complex today

 

SUMMARY OF KEY ISSUES

Staffing : The first alarm response provided a small attack force with limited capabilities. The full response brought only 10 personnel.

Size-up : The first arriving company officer was not able to determine the location and extent of the hidden fire.

Pre-fire plan information: This complex required a pre-fire plan due to the complex arrangement, multiple occupancies, mixed construction, lack of fixed protection, limited access and difficult water supply problems. The first-due company did carry a pre-fire plan that showed the layout of the shopping center and the floor plan for the auto parts store, but the prefire plan was not referenced by the crew during the fire.

Delayed response: The first arriving company was on the scene alone for several minutes with only 3 personnel. The back-up companies had long response times. The lack of evidence of a working fire prompted the initial incident commander to return some of the responding units, resulting in even longer response times.

Water supply: The first-in company did not establish a water supply. This required the second engine company to be committed to this task.

Incident command: The battalion chief was faced with a complicated and rapidly changing situation. He was not able to effectively transfer command from the initial officer and direct the operations of widely separated units.

Operational risk management:The officers involved in the initial part of the operation had to make critical risk management decisions with limited information.

Accountability: Accountability for the personnel operating in the hazardous area was not established prior to the structural collapse. As the situation became critical, no one realized that a crew was still inside the building.

Rapid intervention crew: Additional crews did not arrive in time to assist the crew that was in trouble inside the building.

Radio communications: The lack of a clear radio channel for fire ground communications caused serious problems with command and control of the incident, including the failure to maintain communications with the crew inside and the failure to hear their request for assistance.

Lightweight construction: The roof collapsed quickly and with very little warning. This should be anticipated with a lightweight wood truss roof assembly. This hazard was not recognized by the crews on the scene.

BUILDING DESCRIPTIONConstruction and History

The fire occurred in a modern, lightweight construction building that was added to an existing strip mall in 1984. The older mall on exposure side four was separated from the fire building by a masonry fire wall and was constructed with masonry walls and a steel bar-joist roof structure. The exposures on side two consisted of additional stores that were similar in construction to the auto parts store. There were no exposures on sides one and three.

The auto parts store was constructed with two masonry exterior walls and two wood frame exterior walls, with a lightweight wood truss roof assembly. It was approximately 120 feet deep and 50 feet wide, providing about 6,000 square feet of open display and storage space. The roof assembly was a pre-engineered lightweight wood truss assembled from 2 x 6 top and bottom chords, with 2 x 4 web members held together with metal gusset plates.

  • There were no interior bearing walls or supports for the roof structure. At one end, the trusses were supported by a wood plate that was bolted to a metal beam.
  • The other end rested on top of the concrete block wall. Each truss was separated by 24 inches and they were covered with 1/2 inch CDX plywood sheathing under a two-ply rubber membrane.
  • A drywall ceiling was attached to the underside of the trusses, creating a truss void space (truss loft) 24 to 36 inches above the ceiling.
  • A sheet rock divider was located in the middle of the truss void as a draft stop. The roof had a slight pitch.
  • Three air handling units were on the roof of the building, with an estimated combined weight of 3,000 pounds. It is not known when these units were installed and they may have represented an unanticipated dead load on the roof assembly.
  • There was no indication that the trusses had been reinforced to support the extra weight of these units.
  • The original truss roof structure collapsed during the construction of the building, injuring three workers.
  • Most of the trusses were damaged and had to be replaced at the time. The fire building was occupied by Advance Auto Parts, a chain distributor of automobile part and lubricants. The store was designed with an open retail area containing display racks for goods.
  • A long counter ran from front to back behind which was shelving for additional auto parts. Waste oil and batteries were kept in a rear storage area separated from the front of the store by a drywall wall.
  • The southwest corner of the building contained employee restrooms which had a small water heater located in the ceiling space just above them. The main entrance to the store was through two large glass doors at the front of the building. A delivery and service entrance was located in the rear and a 40 foot trailer was parked behind the building and used for additional storage.

THE FIRE

At approximately 11:00 a.m. on March 18, 1996, a power company employee set up a service truck at the rear of the Indian River Shopping Center in Chesapeake, Virginia. The worker was going to disconnect the electrical power to a customer who had not paid an electrical bill. The customer, a cocktail lounge and bar, was located adjacent to Advance Auto Parts. In preparing to disconnect service, the power company worker elevated the articulating boom on his truck to roof level. Faced with the immediate loss of power, an employee of the lounge paid the electrical bill while the power company employee was beginning work, and went to the back of the store to show the receipt.

A stamped receipt indicates the bill was paid at 11:16 a.m. at a supermarket also located in the shopping center. The power company employee, working from the bucket of the articulating boom, lowered the boom and verified the receipt. Although the bucket had been lowered, the hinged elbow of the articulating boom remained elevated. The employee then radioed his supervisor from the cab of his truck, and received instructions not to disconnect power.

The power company employee then attempted to drive the service truck away, forgetting to secure the boom, which snagged on a power line feeding the meter at the rear of the Advance Auto Parts Store. This caused a phase-to-phase and phase-to-ground arcing fault at the store’s electrical meter, starting the fire. The power company employee immediately stopped, exited his truck, and cut the remaining power connections to the meter at the rear of Advance Auto Parts.

Initial Actions Prior to Calling 911

After cutting the power line to the building, the power company employee removed the meter, noticed smoke coming from the meter base, notified his office and requested that another power company crew and a supervisor come and assist him.

  • An employee of the Advance Auto Parts Store came to the rear of the building and met the power company employee, telling him that the store had lost electrical power and that a fire was being extinguished inside the building.
  • Another Advance Auto Parts employee discharged a dry chemical fire extinguisher on the spot fire that had started near the hot water heater above the employee restrooms.
  • All believed the fire had been extinguished at this time.
  • At 11:29 a.m., the Chesapeake Fire and Police Emergency Operations Center received a 911 call from Advance Auto Parts reporting a problem with the fuse box in the store.
  • The Chesapeake Fire Department was dispatched to a report of a fuse box sparking at 4345 Indian River Road at the Advance Auto Parts store.

Emergency Response

  • Initial response consisted of two engines, a ladder company, and a battalion chief, for a total of 10 personnel.
  • Engine 3 was the first due arriving company, responding from quarters. Engine 1 and Ladder 2 also responded.
  • Battalion 1 was dispatched as the command officer, but requested that Battalion 2 cover the assignment, since he was out of position.
  • Battalion 2 acknowledged the request, and he responded with the first alarm companies.
  • Engine 3’s crew consisted of three personnel: a driver/pump operator; Firefighter- Specialist John Hudgins, serving as Acting Lieutenant for the shift; and Firefighter- Specialist Frank Young, detailed to the station for the day, was riding in the jump seat. Engine 3 was responding in a reserve engine that had a 500 gallon water tank.

 

Initial Size-Up and Company Actions

At approximately 11:35 a.m., about five and a half minutes after dispatch, Engine 3 arrived on the scene at the front of the strip mall.

  • Hudgins reported “a single-story commercial structure, nothing showing from the front. Engine 3 is in command.”
  • Engine 3 took a position in front of the Advance Auto Parts Store. Hudgins and Young entered the structure from the front of the building to investigate.
  • Conditions were clear in the store, and there was no visible smoke or flames showing. They discovered light smoke near the electrical panel in the rear of the building, and radioed to Battalion 2 that they had a fire and were checking for extension.
  • Acting Lieutenant Hudgins then radioed for Engine 3’s driver to reposition the apparatus to the rear of the building.
  • Hudgins then radioed to Battalion 2, who had not yet arrived on the scene, that Engine 3 and Ladder 2 could handle the incident. Battalion 2 and Engine 1, the second due engine company, both went in service.

Engine 3 Reports They Are Trapped, Roof Collapses

At approximately 11:49 a.m., almost 20 minutes after the initial dispatch time, Hudgins radioed that he and Young could not get out of the building. Battalion 2 radioed back that he could not understand their transmission. Hudgins then radioed that they needed someone to come to the front of the building and get them out. Again unable to understand their transmission, Battalion 2 radioed for any unit on the fireground to advise him if they heard the message that was transmitted.

  • Engine 4 responded that they were unable to copy the transmission.
  • Engine 14 then marked on the scene and was instructed by Battalion 2 to lay a supply line to the front of the building. Battalion 1, enroute to the fire on the second alarm, radioed to Battalion 2 that it sounded like someone was trapped inside.
  • Battalion 3, also enroute, radioed that he would be on the scene momentarily and would assist.

At this time, Ladder 2’s crew was setting the outriggers and preparing to elevate their aerial ladder for defensive operations.

  • In the short time it took to accomplish the stabilization of the ladder truck, the front of the store became fully involved, the building contents ignited, and the roof collapsed.
  • Due to the radiant heat, Ladder 2 was forced to retract their outriggers and reposition to a safer defensive position on side one of the structure, and set up the aerial again.
  • Ladder 2’s crew did not hear Engine 3’s transmission that they were trapped.
  • Simultaneously, Engine 1 ran out of supply line about 200 feet short of the hydrant. Engine 2, responding on the second alarm, picked up the hydrant that Engine 1 was attempting to reach and laid a supply line to side one.
  • The driver of Engine 1 attempted to contact his officer by radio to advise that he could not reach the hydrant, but could not get through due to heavy radio traffic.
  • He parked the engine in the roadway, donned his SCBA, and went to the rear of the building to report to his Captain and rejoin his crew.
  • Battalion 3 arrived on side one about this time and radioed for all companies to switch to channel two, an alternate fireground tactical frequency.

Driven by the northerly wind and the draft created by the burning contents of the structure, the fire at the rear had grown in such intensity that personnel were forced to move Engine 3. Assisted by employees of the power company, Engine 3 was moved back away from the rear of the building. At 11:55 a.m., about 26 minutes after dispatch, the Captain of Engine 1, with his crew at the rear of the building, confirmed to Battalion 2 that “I got men on the inside from Engine 3, and the lines have been burned. I do not know their status, and we still have no water to go in after them.”

Battalion 3 met with Battalion 2 and discussed that they may have lost a crew inside. Battalion 3 assumed command and Battalion 2 went to the rear of the building to coordinate rescue efforts. There, Battalion 2 met with the Captain from Engine 1.

By this time, the building was fully involved and no rescue efforts could be mounted until the fire was knocked down. Officers at the front and the rear attempted to conduct a personnel accountability report (PAR) to determine who was missing and where they might be located.

  • An engine company responding on mutual aid from the Virginia Beach Fire Department was flagged down, connected to Engine 1’s supply line, and completed the water supply to a hydrant behind the shopping center within the City of Virginia Beach. Engine 3 was forced to move back once again, and the supply line was disconnected from Engine 3 and used to supply water to Engine 4, a telesquirt that was positioned for defensive operations at the rear.

Extinguishment and Body Recovery

The fire spread to the attic of the exposures on side two and was held in check by the fire wall on side four of the building. The fire was brought under control as the contents of the auto parts store burned off and several aerial streams were put into operation. After the fire was extinguished, a search for the missing firefighters was initiated. After the bodies of the firefighters were located, they were removed from the fire building by members of the Virginia Beach Fire Department, and transferred by members of the Chesapeake Fire Department to medic units.

The body recovery was supervised by the Chesapeake Fire Department Fire Marshal’s Office and documented. An investigation was immediately started by the Chesapeake Fire Department Fire Marshal.

ANALYSIS

Fire Cause and Flame Spread

  • The fire was caused by the electrical short created when the power company truck struck the power line to the building. Investigation by the City of Chesapeake Electrical Inspector after the fire revealed that the meter contained wiring that appeared to have been tampered with and did not comply with the electrical code.
  • Several connections at the meter had been double-lugged, connecting multiple wires to single terminals. Additional investigation by Virginia Power revealed that the building may have been improperly grounded, leading to numerous hot connections when the short circuit occurred. The main fuse did not trip at the breaker panel and the wiring on all three air handling units had been fused. This probably resulted in the ignition of multiple spot fires in the truss loft above the store.
  • It appears that the fires in the truss loft were still relatively minor when Engine 3 arrived, but the fire spread rapidly throughout the space due to the light wood construction.
  • The wind drawn from the open doors at the front of the building also promoted rapid fire growth. This would have created a tremendous hidden fire in the wood truss loft area despite clear conditions inside the structure.
  • Reports of heavy smoke and fire conditions on the roof at the same time Engine 3’s crew was calling for pike poles and personnel to come inside are indications towards this scenario.
  • The interior of the auto parts store contained racks of auto parts and supplies, including oil, lubricants, rubber, and plastic parts. The contents were packed closely together and stored in tall racks near the ceiling.
  • Once the fire had broken through the ceiling in the rear of the building, these contents would have quickly reached their ignition temperatures, creating flashover conditions in the rear of the store as the fire progressed, trapping the firefighters and forcing them to seek an exit at the front of the store.

Roof Collapse

  • The collapse of the pre-engineered truss roof occurred approximately 21 minutes after the time of dispatch, and within 35 minutes of the initial accident, that caused the electrical short.
  • The structure appears to have collapsed within 10 to 12 minutes after the truss space became heavily involved.
  • The collapse of similar truss assemblies under fire conditions within this time period has been well documented.
  • Post-incident investigations indicate that this truss assembly may have been weakened by deficiencies in the connection of the trusses to the beam on the east side of the building.
  • Also, the dead load of the three air conditioning units may have contributed to the rapid failure of the roof.
  • Reports from firefighters on the scene indicate that a partial failure of the truss assembly may have occurred in the rear of the building, followed shortly by the failure of the entire roof assembly.
  • It is possible that the crew of Engine 3 was trapped by the partial collapse of the roof in the rear, or by the collapse of racks containing auto parts in the building, or by the rapid spread of the fire and smoke which had broken through the ceiling.
  • It is also possible that a combination of these events occurred simultaneously. The failure of the entire roof assembly and complete involvement of the interior of the building with fire took place within one minute after the firefighters radioed for help, before any reaction to assist them could take place.

Fire Operations

 

Initial Response - The first alarm assignment was overwhelmed by the situation, the circumstances, and the unusual sequence of events that occurred at this incident. It is evident that a larger force would have been needed to initiate an effective offensive or defensive operation for a working fire in a 6,000 square foot commercial occupancy, with attached exposures on two sides, with or without the unusual complications.

  • The response of two engine companies, one ladder company and a battalion chief, provided a total of 25 only 10 personnel on the initial assignment.
  • The individual companies, which responded with three person crews, had limited capabilities to perform tasks independently.
  • This incident generated only a single call to 9-1-1 reporting an electrical problem.

 

LESSONS LEARNED AND REINFORCED

1. RISK ASSESSMENT is the primary responsibility of the incident commander.

This incident presented a very high risk to the firefighters who were attempting to make an interior attack. However, the risk factors were not recognized and the interior crew was not directed to abandon the building. Risk assessment should be a continual process, particularly when a situation is changing very quickly.

2. ACCOUNTABILITY is an essential function of the Incident Command System.

The location and operation of the initial attack crew was not tracked according to the incident command system that was in effect at the time of the fire. The system must keep track of the location, function, status, and assignment of every individual unit or company operating at the scene of an emergency incident. In order to be effective, the accountability process must be routinely initiated at the beginning of every incident and updated as the incident progresses and units are reassigned to different tasks.

3. TACTICAL RADIO CHANNELS are essential for firefighter safety.

The fireground operations were conducted on the same radio channel as the routine dispatch and transfer of additional units, hampering the fireground communications during the important early stages of the incident. Designated radio channels should be set aside specifically for communications between the incident commander and the units operating at the scene of an incident. The exchange of information, orders, instructions, warnings, and progress reports is essential to support safe and effective operations. Tactical channels should be assigned early and routinely to avoid the confusion that occurs when units that are already working are directed to switch to a different radio channel.

4. FIRE OPERATIONS must be limited to those functions that can be performed safely with the number of personnel that are available at the scene of an incident.

The initial response to this incident did not provide enough resources to safely initiate an effective interior attack for the situation that was encountered. The first arriving company initiated interior operations that could not be adequately performed or supported with the limited number of personnel at the scene or responding. The delayed arrival of back-up companies increased the risk exposure of the first due company. The situation called for a more conservative initial attack plan and/or an early retreat when the magnitude of the fire became evident.

5. WATER SUPPLY is a critical component of a safe and successful operation.

The failed attempt to establish an adequate and reliable water supply for the interior attack was a critical problem at this incident. This task occupied the second due engine company which was needed to provide either a back-up hose line to support the interior attack or a rapid intervention crew.

6. LIGHTWEIGHT WOOD TRUSS CONSTRUCTION is prone to rapid failure under fire conditions.

If the construction of the building had been known or recognized, the early failure of the roof structure should have been anticipated and the interior crew should have been withdrawn. This requires pre-fire planning to identify high risk properties and a reliable system to label the building or to inform the responding units of the risk factors of the building. It is usually difficult or impossible to make this determination when the building is burning.

Aerial View of the Current Auto Parts Store 2010

 

USFA Technical Report Series Incident Report: Tr-087 NFPA 1996 Report Summary Sheet: NFPAChesapeake

Chicago Fire Captain Herbie Johnson remembered for his kindness, humor, bravery

No comments

Captain Herbie Johnson, CFD

 

Photo By Tim Olk (all rights reserved)
http://olkee.smugmug.com/Mabas-Division-9-City-Of/CFD-Funerals/Chicago-Detment/26417819_vPkW9J#!i=2203991836&k=XDgP8TT

 

  • Chicago Tribune Photos, HERE
  • Tim Olk Photos, HERE
  • Chicago Tribune, HERE
  • “We could not be prouder of you,”  brother of fallen firefighter says Sun-Times HERE
  • See CommandSafety.com for a complete accounting of the event, HERE
  • Family of fallen firefighter: ‘A hero for our city’ from the Chicago Tribune, HERE

  • Related
  • Deadly fire on Chicago's South Side
  • PHOTOS:  Deadly fire on Chicago’s South Side

 

 

 

Photo: E. Jason Wambsgans/Chicago Tribune

 

What will define you as a Firefigher, as an Officer…as a person?

 

 

“You don’t need a last name for Herbie. Everybody knew Herbie”; Chicago Fire Capt. Herbie Johnson

No comments

Chicago firefighter Herbert Johnson, left, poses with Chicago Fire Commissioner Jose Santiago, right, after Johnson was promoted to the rank of captain. Johnson died from injuries sustained while fighting a house fire on the South Side. — Chicago Fire Department

 ”You don’t need a last name for Herbie. Everybody knew Herbie”.   A beloved firefighter, Fire officer, father and husband died in the line of duty on Friday November 2, in the City of Chicago protecting the citizens of his city working with the companies assigned to the structure fire alarm.

Chicago Captain Herbert Johnson, 54, suffered second- and third-degree burns during fire suppression operations being conducted in the attic of the residential house at 2315 West 50th Place, according to Chicago FD officials and published media reports. The 32-year veteran of the Chicago Fire Department died Friday night after he and another firefighter were injured in a blaze that spread quickly through the 2-1/2 story wood frame house. A second firefighter, FF Brian Woods was also injured and was reported in good condition at Advocate Christ Medical Center in Oak Lawn, according to a department spokeswoman, and was subsequently released. Chicago fire investigators are considering the possibility that a malfunctioning water heater sparked the fire that killed Capt. Herbert Johnson, a Fire Department spokesman said Saturday.

  • See CommandSafety.com for a complete accounting of the event, HERE
  • Family of fallen firefighter: ‘A hero for our city’ from the Chicago Tribune, HERE

Captain Johnson, was promoted from lieutenant this summer and was assigned to Engine Co. 123 in Back of the Yards Section of Chicago for the night tour but normally worked all around the City of Chicago.

Capt. Johnson from a 2006 Sun-Times photo

The following exerpt from the Chicago Tribune helps define the type of firefighter Capt. Johnson was:

http://www.chicagotribune.com/news/local/ct-met-firefighter-killed-folo-20121104,0,5331508.story

Johnson’s influence on everyone he met was visible Saturday, with shrines at the site of his death and trees in his family’s Morgan Park neighborhood decorated with purple and black bows.

A 32-year veteran of the department, Johnson volunteered in 2001 to help with rescue efforts in New York after the 9/11 attacks. As a lieutenant in 2007, he received a Medal of Honor for outstanding bravery or heroism, the state’s highest accolade for firefighters — the result, his family said, of helping rescue children the year before from a burning building on the South Side.

Friends and family remembered him mostly for his jovial personality and tender heart, a burly man with a beaming smile who once took a sewing class so he could make a First Communion dress for his daughter.

Johnson and his sister, Julie, even went to clown school together, said their brother John Johnson, a Chicago police officer. That sister, a former police officer who is now a nurse, celebrated her birthday Friday, the day of Johnson’s death, family members said.

Their father worked for the city in the Streets and Sanitation Department, John Johnson said, and their grandfathers were Chicago police officers.

The eldest of eight children, Johnson always knew he wanted to be a firefighter, said his family members, many of whom are also in public service.

“He lived for it,” brother-in-law McMahon, said.

“He died for it,” John Johnson added.

 From the Chicago Tribune (HERE);

Just like every little boy that’s grown up in the last 20 years wanted to be Michael Jordan or Brian Urlacher, every firefighter that worked with him wanted to be Herbie,” said Tim O’Brien, a spokesman with Chicago Fire Fighters Union Local 2. “You aspired to be more like him in every way of life.”

Colleagues said Johnson spent the last several years working as an instructor at the Fire Academy. Generous and kind, he never missed a Fire Department fundraising event, they said. His helpful nature also extended beyond the firehouse, friends said, through coaching youth sports and volunteering at his church parish.

He always had a funny story and often left fellow firefighters in stitches, sometimes through his own distinctive belly laugh, colleagues said.

From The Chicago Sun-Times (HERE):

“He was always a hero to us and now he’s a hero for our city,” McMahon said. “Herbie never wanted glory or notoriety. Instead, all he wanted was to make Chicago a safer place for other members of the city. So please, in Herbie’s honor, check your smoke detectors right now, give your kids a hug.”

Johnson was an easy man to know and love, said friend Tom Taff, who runs a camp for burn victims that Johnson helped support. The recently promoted captain personified joie de vivre, a man with a big laugh who drove fire engines in parades, cooked for charity ­— left an impression in the many places he offered his service.

 

Readings and Learnings

Additional Coverage and Links

  • From Chicago WGNTV, HERE
  • From the Chicago Tribune, HERE and HERE
  • From the Chicago Sun Times, HERE
  • Photo Gallery from the Sun-Times, HERE
  • Photo Gallery from the Chicago Tribune, HERE
  • Aerial Fireground Operations, Chicago ABC 7 News, HERE
  • Google Maps; StreetView Images, HERE
  • Chicago CBS, HERE
  • 2007 Illinois Fallen Firefighter Memorial and Firefighting Medal of Honor Ceremony, HERE
  • Remembering Capt. Herbie Johnson: “To Know Him, Was to Love Him” HERE

 

 

Photo Credit: Tim Olk
https://www.facebook.com/tim.olk.75
http://olkee.smugmug.com/

VISITATION: Wednesday, November 7, 2012 at St. Rita High School, 7740 S. Western from 3-9 PM.
FUNERAL MASS: Thursday, November 8, 2012 at St. Rita High School at 11:00 AM

 

 

 

Family, friends gather to mourn fallen firefighter Herbert Johnson, Chicago Sun-Times Additional Video HERE

 

SFFD Firefighter Memorials and Updates

No comments

More details emerged Monday about last week’s fatal Diamond Heights blaze, as fire officials said an emergency alert accidentally went off on a nearby fire engine about the same time two firefighters’ personal alarms sounded inside the burning building according to published reports.

Lt. Vincent Perez, 48, and firefighter-paramedic Anthony Valerio, 53, of Engine Company 26 both died from injuries they suffered while battling a blaze at a four-story home at 133 Berkeley Way on Thursday morning.

While fighting the fire, one or both of Valerio and Perez’s personal alert safety system devices went off.  Around the same time, a firefighter on Engine Company 20 — which had yet to arrive on the scene — had inadvertently hit the emergency button on the engine.

Firefighter memorials

A joint funeral for fire Lt. Vincent Perez and firefighter-paramedic Anthony Valerio will be held at 12:30 p.m. Friday at St. Mary’s Cathedral, 1111 Gough St. in San Francisco. A vigil for the two men will be held at 7 p.m. Thursday, also at St. Mary’s.

San Francisco Fire Fighters Local 798 has established trust accounts at the San Francisco Fire Credit Union for the families of Perez and Valerio. Donations can be made to SFFCU, 3201 California St., San Francisco, CA 94118.

Condolence messages can be sent to Fire Station 26, 80 Digby St., San Francisco, CA 94131.

Eleven Minutes to Mayday; What You Need to Know

2 comments

The Colerain Township (OH) Fire and EMS Department under the leadership of Director and Chief G. Bruce Smith released its final report Investigation Analysis of the Squirrels nest Lane Firefighter Line of Duty Deaths related to the April 4, 2008 Double Line of Duty Death of a Captain and Firefighter in April 2010 coinciding with the two year anniversary of the event.

This investigative analysis and report, although specific to the events and conditions encountered during the conduct of operation at the residential occupancy at 5708 Squirrelsnest Lane has pertinent and relevant insights, recommendations and factors that all Fire Service personnel, regardless of rank should read.

I recently lectured on this incident and the lessons learned at a regional seminar on occupancy profiling and tactical operations, which resulted in significant discussions and dialog pertaining not only to this event but also to the adverse trend and series of  incidents reported nationally in the later part of 2010 and early into 2011 related to comprised or collapsed floor systems and a number of firefighter close calls. There continues to be a number of prevailing philosphies and points of view related to the level of fire ground aggressiveness, tactical patience and level of preparedness demanded on today’s fire ground. I’ve previously posted some insights on these events and these points of view on our Commandsafety.com site and other eMedia sites.

There still appears to be so much that needs to said; lectured, taught, reinforced or just plain introduced to get company and command officers “insightful” into the operational issues affecting modern fire suppression theory, methodologies, operational safety at basement fires or lower elevation fires, compromise and collapse situational awareness, being combat ready during the response and into arrival sequencing and being able to read the building  and fire more effectively and accurately.

I recently had the honor to facilitated an insightful radio program on Taking it to the Streets related to a close-call resulting from a catastrophic and complete floor system collapse in a residential occpancy(HERE) during fire suppression operations and the lessons learned and insights from that event and its recording in the National Firefigher Near Miss Reporting System. Take the time to read about the event ( NMR Report #10-1072) or download the program.

There are tremendous lessons to be shared and learned from the Colerain Township incident, and its one of the required readings that all command and company officers should have on their radar screen (see Commandsafety.com, HERE)

This is one of those distinctive reports that has influential and critical operational, training and preparedness elements embedded throughout the report. Following my review of the report, having previously read the preliminary report findings, it is apparent there continues to be common threads shared by this and other events and incidents where a single of multiple firefighters have lost their lives due to similarities in the apparent and common cause deficiencies and short comings identified.

All company and command officers should read and comprehend the lessons learned. Then, take these new found insights and see what the gaps are at the personal level (yours or those you supervise) as well as the shift, group, station, battalion, division or department as a whole.

If there are gaps, then identify a way to implement timely changes as necessary so there are No History Repeating (HRE) events. Learn from these events….

Thank you to the firefighters, officers and leadership of the Colerain Township (OH) Fire and EMS Department for the comprehensive insights that this report provides and towards the promise that these lessons-learned may one day help a firefighter, crew, company or fire ground in their combat engagement and mission. Do not take any run or response for granted; be combat ready at all levels.

I have provided a comprehensive synopsis of the report for your review. Take the time to read the entire report, make the time to improve where you need to.  

On Friday, April 4, 2008 at 06:13:02 hours, what began as a routine response for Colerain Township Fire and EMS Engine 102 to investigate a fire alarm activation at 5708 Squirrels nest Lane, Colerain Township, Ohio resulted in the deaths of Colerain Township Captain Robin Broxterman and Firefighter Brian Schira.

Upon their arrival at the scene of the two-story wood framed, residential building working fire conditions existed in the basement. The initial attack team consisted of Broxterman, Schira, and one other firefighter. The team advanced a 1¾-inch attack hose line through the interior of the building for fire control.

Even though, they were provided with some of the most technologically advanced protective clothing for structural firefighting and self-contained breathing apparatus, it appeared that Broxterman and Schira were overwhelmed by severe fire conditions in the basement.

During their attempt to evacuate the building, the main-level family room flooring system in which the two were traveling on collapsed into the basement trapping the firefighters. Eleven minutes elapsed from time of arrival to the catastrophic chain of events.

The investigation of this incident provided a number of findings and recommendations that should be considered by Colerain’s fire department, as well as other fire department organizations. The examination encompassed issues that related to building construction, firefighting tactics, command and control, situational awareness, communications, training, firefighting equipment and the individual responsibility of firefighters of the Colerain Township Department of Fire and Emergency Medical Services (Colerain Fire & EMS). In addition, a segment of the examination included a review of the individual and group affects following such an event, and the measures initiated that attempted to ensure individual, family and organizational wellness.

The following factors were believed to have directly contributed to the deaths of Captain Broxterman and Firefighter Schira:

  • A delayed arrival at the incident scene that allowed the fire to progress significantly;
  • A failure to adhere to fundamental firefighting practices; and
  • A failure to abide by fundamental firefighter self-rescue and survival concepts

Although the aforementioned factors were believed to have directly contributed to their deaths, they might have been prevented if:

  • Some personnel had not been complacent or apathetic in their initial approach to this incident;
  • Some personnel were in a proper state of mind that made them more observant of their surroundings and indicators;
  • The initial responding units were provided with all pertinent information in a
  • timely manner relative to the incident;
  • Personnel assigned to Engine 102 possessed a comprehensive knowledge of their first-due response area;
  • A 360-degree size-up of the building accompanied by a risk – benefit analysis
  • was conducted by the company officer prior to initiating interior fire suppression operations;
  • Comprehensive standard operating guidelines specifically related to structural
  • firefighting existed within the department;
  • The communications system users (on-scene firefighters and those monitoring the incident) weren’t all vying for limited radio air time;
  • The communications equipment and accessories utilized were more appropriate for the firefighting environment;
  • Certain tactical-level decisions and actions were based on the specific conditions;
  • Personnel had initiated fundamental measures to engage in if they were to become disoriented or trapped inside a burning building; and
  • Issued personal protective equipment was utilized in the correct manner.

Incident Reported

On Friday, April 4, 2008, at 06:11:23, the Hamilton County Communications Center (HCCC) received notification of an automatic alarm activation (smoke detector and carbon monoxide) at 5708 Squirrels nest Lane (LN).

  • An automatic fire alarm response complement of two engine companies (Engines 102 & 109), one ladder company (Ladder 25), and the Battalion Chief (District 25) were dispatched to investigate at 06:13:02.
  • At 06:13:43, a second notification was received from the female homeowner reporting a fire in the basement of the building.
  • At 06:20:43, a third notification by means of a cellular phone from the female homeowner to HCCC routed through the City of Cincinnati’s Fire and Police Communications Center was received.
  • At 06:22:41, the initial response complement was then upgraded to a building fire, also known as a structure fire response complement to include one additional engine company (Engine 25), one rescue company (Rescue 26), and one basic life support transport unit (Squad 25).

Property and Building Description: The building at 5708 Squirrels nest LN was a single-family residence that set back approximately 450-feet from the street at the end of a private driveway on a heavily wooded lot.

  • The building was two-stories in height, approximately 45-feet wide by 30-feet deep with a finished below-grade (basement) living space and attached two-car garage.
  • For simplicity, the report refers to the living space under the main-level of the building as a basement.
  • From the front (side Alpha), the building was two-stories above grade. The vertical distance between floors was approximately eight-feet. The exterior main entrance was located in the front middle of the building approximately one-foot above grade level.
  • Additional entrances to the first-floor living space were by means of a rear entry door from an upper-level deck area and through the garage area.
  • The interior stairway to the basement was located approximately 15-feet from the front main entry door towards the rear of the building. There were no exposed buildings on the adjacent sides of the fire building.

The building was located approximately 450-feet from the curb and a driveway leading to the front entrance. The nearest fire hydrant was located approximately 500- feet from the front entrance. To provide for uniform identification of locations and operationalforces at the incident scene, the scene was divided geographically into smaller parts, which were designated as sectors. Specific areas of the incident scene were designated as follows:

  • The side of the building that bears the postal address of the location was designated as Side Alpha or front by the Incident Commander;
  • The property sloped downward towards the rear (side Charlie) of the building with an approximate 13-foot elevation difference from side Alpha to Charlie. The
  • Charlie side of the building was three-stories above the rear grade level with the building’s basement floor approximately five-feet above grade level. The exterior entrance to the building’s’ basement area, also known as a walk-out was by means of a stairway that led to a wooden deck on the Charlie side adjacent to the Delta side. A second stairway led to an upper level deck that served the main level of the building.

Initial Fire Attack Operation: Upon arrival at the incident address, Engine 102 (E102), assigned four personnel (one captain, one fire apparatus operator [FAO], and two firefighters) entered and proceeded down the driveway deploying a five-inch supply hose line.

  • With their apparatus positioned in front of the building Captain (Capt.) Broxterman radioed, “Moderate smoke showing. E102 will be Squirrelsnest Command.” at 06:24:01.
  • Verification was made by the E102’s FAO through face-to-face communication with the male homeowner that all occupants were out of the building, which was then relayed to Capt. Broxterman.

District 25 (D25) arrived at the scene at 06:26:35 and assumed Command from Capt. Broxterman. Capt. Broxterman, Firefighter (Ffr.) Schira and E102’s Ffr. #2 advanced a 1¾-inch pre-connected hose line through the front main entrance. The fire was determined to be located in the basement of the building.

  • At 06:27:52, Capt. Broxterman radioed, “E102 making entry into the basement, heavy smoke”.
  • At 06:30:35, E109′s captain radioed, “Command from E109, contact 102,have them pull out of the first floor, redeploy to the back. It’s easy access. Conditions are changing at the front door.”
  • At 06:34:48, Engine 25 (E25), the designated Rapid Assistance Team, had just completed their 360-degree size-up around the building, and encountered E102’s Ffr. #2 in front of the building, whom reported that he had lost contact with his crew.
  • During the time period between 06:29:24 and 06:34:48, the investigation committee believed that one or more catastrophic events occurred including a failure of the main-level flooring system near the Beta – Charlie corner of the building.

 Rescue and Recovery Operations

  • At 06:35:34, the Incident Commander (IC) identified a potential Mayday operation, which indicates a life threatening situation to a firefighter.  
  • RAT25 was deployed at 06:36:48. The actual Mayday operation was initiated by the IC at 06:37:41 followed by a request at 06:37:53 to the HCCC for a second alarm complement of firefighting resources.  
  • At 06:42:01, RAT25 entered the basement from the rear of the building. At 07:00:27, E26’s personnel entered through the front main entrance of the building and into the basement by means of the interior stairway.  
  • Both missing firefighters were located in the basement near the Charlie side wall adjacent to the Beta side following a floor collapse. Capt. Broxterman and Ffr. Schira were obviously deceased as a result of their injuries.

Fire Origin and Cause: Information from the property owners was that the female had smelled an odor in the house. She told her husband, who went to investigate. Neither of them observed any smoke or flames at that time. The husband went to the basement, and located a fire near a cedar wood lined closet used to cultivate orchids in the unfinished utility room. He attempted to extinguish the fire with portable fire extinguishers and pans of water. As the fire alarm activated, the husband had his wife call 9-1-1 to report the fire. The state of Ohio Fire Marshal’s Office Fire and Explosion Investigation Bureau ruled the fire to be accidental in nature. The fire was determined to have originated in the unfinished utility room of the basement level in or near the cedar closet. This area was directly below the family room on the first floor. The probable ignition source for this fire was determined to be at and about a plastic air circulation fan and the associated electrical wiring.

Cause of Deaths

Capt. Broxterman was a 37-year old employee of the Colerain Fire & EMS with approximately 17-years of certified firefighting experience. Capt. Broxterman became trapped in the basement area for a prolonged amount of time following the sudden floor collapse. Capt. Broxterman was found positioned face down over top of Ffr. Schira. The majority of her protective clothing ensemble and equipment were heavily damaged as a result of exposure to heat and direct flame impingement. She was pronounced deceased following her removal from the building. Her body was transported to the Hamilton County Coroner’s Office for autopsy. The Coroner’s report cited the manner of death as “accidental” and the cause of death as “burns and inhalation of smoke and superheated and noxious gases.” Capt. Broxterman sustained burns to 100% of her body surface, which ranged from first to fourth degree in severity as described in the coroner’s autopsy report. Postmortem carboxyhemoglobin (COHb), which is a measure of carbon monoxide exposure, was measured at 22% saturation and soot was observed in portions of her upper and lower respiratory system.

  • Based on the injuries sustained and the damage to Capt. Broxterman’s protective clothing ensemble and equipment, it is likely that she was exposed to a rapid intensification of heat and flames in the building’s basement that overwhelmed her protective ensemble and equipment, exposing her body and respiratory system to intense heat and toxic products of combustion.

Ffr. Schira was a 29-year old employee of Colerain Fire & EMS with approximately 3½-years of certified firefighting experience. He also became trapped in the basement area for a prolonged amount of time following the sudden floor collapse. Ffr. Schira was found positioned on his right side and back, face-up beneath Capt. Broxterman. The majority of his protective clothing ensemble and equipment was heavily damaged as a result of exposure to heat and direct flame impingement. Ffr. Schira was pronounced deceased following his removal from the building. His body was transported to the Hamilton County Coroner’s Office for autopsy. The Coroner’s report cited the manner of death as “accidental” and the cause of death as “burns and inhalation of smoke and superheated and noxious gases”. Ffr. Schira sustained burns to 100% of his body surface, which ranged from first to fourth degree in severity as described in the coroner’s autopsy report. Postmortem COhb was measured at 8% saturation and soot was observed in portions of his upper and lower respiratory system.

  • Based on the injuries sustained and the damage to Ffr. Schira’s protective equipment, it is likely that that he was exposed to a rapid intensification of heat and flames in the building’s basement that overwhelmed his protective ensemble and equipment, exposing his body and respiratory system to intense heat and toxic products of combustion.

Select Findings and Recommendations

Findings, Discussions and Recommendations

FINDING #3.1: The area of fire origin had no finished ceiling, which exposed the floor joists and the underside of the floor decking to direct fire impingement causing rapid deterioration and failure of the flooring system directly underneath the main-level family room.

During this incident, based on communications transcripts (telephone and radio) it’s probable that the fire had advanced from its incipient stage to a free burning stage in approximately 18 to 20-minutes by the time Capt. Broxterman radioed that they were making entry into the basement.

  • As stated in the Incident Overview section, during the time period between 06:29:24 and 06:34:48, it is believed that one or more catastrophic events occurred within the building, which included a failure of the flooring system near the Beta-Charlie corner of the building’s first floor.

It has been widely believed in the firefighting profession that traditional sawn lumber is far superior to some of the more innovative lightweight construction components (e.g., wood I-joist) in use today. With dimensional lumber, two-inch by eight-inch and larger, there is a greater surface to mass ratio to resist the damaging effects of fire and the structural components will maintain their integrity for a longer period of time. While this has traditionally been accurate, this incident clearly shows that this may not always be the case. Heavy charring was evident to structural members in the fire area of origin. Notice the burn damage shows how the wooden floor joists had been burned to and away from the band joist. A band joist is a vertical member that forms the perimeter of a floor system in which the floor joists tie in to. Also known as the rim joist. Early platform framed homes very likely used solid, dimensional lumber and plywood, which provided a reasonable surface to mass ratio. But the later the home was built, the less mass even dimensional lumber has due to the reduction in the actual thickness of solid dimensional lumber provided by the lumber industry through the mid-1900’s. As the years go by, building materials will likely keep getting lighter and lighter and introduce more resins and other chemicals.

Laboratory tests that exposed structural wood components to the American Society for Testing and Materials (ASTM) E119 Assembly Test indicated that a traditional two-inch by ten-inch structural member failed in 12-minutes and six-seconds. ASTM E119 test is the standard test method for evaluating building and construction materials exposed to fire. Unlike the standardized ASTM test fires, it is widely recognized that real building fires are highly variable in their size, rate of growth and intensity. Responding firefighters are unlikely to know when a given fire started, how hot it had been prior to arrival, how long it had been at any given temperature, the design capacity and actual loads on the floors over the fire or the amount of actual damage that the fire may have done to the joists. All of these factors make it impossible to predict the remaining capacity of a floor by even the most knowledgeable, professional fire experts.

RECOMMENDATION #3.1a: Fire departments should ensure that firefighters and incident commanders are aware that unprotected floor and ceiling joist systems, no matter the type, may fail at a faster rate when exposed to direct fire impingement.

Unfinished basement ceilings and other areas that have exposed joists or trusses jeopardize flooring and roof systems unnecessarily during a fire, causing premature failure. Often, a weakened floor and ceiling joist system can be difficult to detect from above as the floor surface above may still appear intact. Firefighters operating on floors above fire-damaged joist systems may fall through a weakened area and become trapped in a fire below. IC’s and firefighters must be aware that these systems can fail rapidly and without warning, and plan interior operations accordingly.

Firefighters must also be aware that while floor sag may be a widely accepted warning of an impending structural failure, floor sag is not always present or visible prior to a catastrophic collapse in a fire, regardless of the joist type, due to floor coverings, the fire’s intensity, the combination of joist spans and loads present, the location of serious structural fire damage or simply because it is too dark and smoky to see a sag in the floor. This is true for all types of structural joists, including materials such as sawn lumber, wood I-joists, and open web wood trusses and noncombustible members such as lightweight steel joists. The floor covering in this area was carpeting that transitioned to ceramic tile. When unprotected, any traditional or lightweight residential floor or ceiling assembly material, either combustible or noncombustible, may fail within several minutes of the fire’s ignition. It makes sense, therefore, that when there is a serious fire beneath a floor, there is no predictable safe amount of time that anyone can remain on that floor. Any floor system protected or not, can fail unpredictably when exposed to a substantial fire beneath.

FINDING # 4.2: E102′s officer failed to properly analyze the scene by not performing a 360-degree scene size-up to determine an overall strategy, and implement safe and effective firefighting tactics.

After the apparatus was positioned in front of the building, E102’s FAO was ordered by Capt. Broxterman to, “Ask the homeowner where the fire [location] was”, which was indicated to be in the basement by the male homeowner. As this was taking place, Capt. Broxterman continued donning her protective clothing ensemble (coat, helmet and self-contained breathing apparatus). Although E102′s officer provided a brief radio report of conditions observed upon arrival, she did not properly evaluate the scene so as to develop a basic strategy for implementation of safe and effective firefighting tactics. Had the officer visually evaluated the Charlie side of the building, the advanced fire conditions may have been noted, and that the lower level fire area was accessible by means of an exterior entry door for a more direct fire attack from the interior unburned side.

This means that firefighters enter a building and position the attack hose line between the fire and the uninvolved portions of the building. This direction of fire attack is preferred because it is likely to contain the fire, protect occupants, and push heat and gases out of the building if ventilation has been performed. On the other hand, danger increases significantly when attacking from the unburned side and is not always practical based on fire location, intensity, and building construction.

It cannot be conclusively known as to why Capt. Broxterman and Ffr. Schira proceeded into the area of the building that eventually collapsed resulting in their deaths. The investigation committee has concluded that the most probable explanation is that E102′s three-person interior team was successful in advancing their uncharged attack hose line into the basement recreation room area; reaching a point approximately 10 to15-feet from the bottom of the basement stairway as shown in the Incident Overview chapter. Once the team reached this area, it was realized they did not have sufficient hose line to continue advancing towards the seat of the fire. The team’s third member (Ffr. #2) reversed his travel and made his way back to the exterior of the building to advance additional hose line. As the team of two waited for additional hose line to be stretched and the hose line to be charged by the pump operator, the interior conditions rapidly deteriorated to a stage that it became untenable for them to hold their position.

The team evacuated back-up the stairway without following the hose line, which by all indications was tight up against the stairway wall and tightly wrapped around the stairway door entry. Once at the top of the stairway, one of the two deceased, if not both were likely in some form of distress; became disoriented and proceeded into the family room in a direction opposite the route of travel from which they entered the building. As the two moved across the family room floor, the flooring system collapsed into the utility room area of the basement. When the third team member re-entered the building, he was unable to locate the other two members.

The inability of Ffr. #2 to locate his team and the loss of radio communications contact with the interior team prompted the IC to declare a Mayday and activation of the RATs. This incident resulted in tragedy primarily due to the concealment of several burned-through floor joists under the carpet covered flooring system, which was nearly impossible to recognize due to heavy smoke conditions inside the burning building.

The following factors are believed to have directly contributed to the deaths that occurred in this incident:

  • The delayed arrival at the incident scene allowed the fire to progress significantly and the hazardous conditions to exponentially increase;
  • The failure to adhere to fundamental firefighting practices (e.g., entry into an enclosed building with obvious working fire conditions without a charged attack hose line)
  • The failure to abide by the fundamental concepts of fire fighter self-rescue and survival (e.g., following of the hose line in the direction of travel back to the building’s entrance or exit).

Although the aforementioned factors are believed to have directly contributed to the deaths reported here, they might have been prevented if:

  • Some personnel had not been complacent or apathetic in their initial approach to this incident which eventually led to being overwhelmed in their response to their initial findings;
  • Some personnel were in a proper state of mind that made them more observant of their surroundings and indicators, and the potential threats and risks that presented themselves;
  • The initial responding units were provided with all pertinent information in a
  • timely manner relative to the incident, especially critical was the information given to the emergency communications center from the homeowners reporting an actual fire
  • Personnel assigned to E102 possessed a comprehensive knowledge of their firstdue response area specifically related to road and street locations, and any particular characteristics related to those areas.
  • A 360-degree size-up of the building accompanied by a risk – benefit analysis was conducted by the company officer prior to initiating interior fire suppression operations; the risk of an action must be weighed against the probable benefit that may be reasonably and realistically expected.
  • Comprehensive standard operating guidelines specifically related to structural firefighting existed within the department;
  • The communications system users (on-scene firefighters and those monitoring the incident) weren’t all vying for limited radio air time. This competition led to missed and distorted messages and less than efficient use of resources, which exacerbated the problems of already taxed communications.
  • The communications equipment and accessories utilized were more appropriate for the firefighting environment;
  • Certain tactical-level decisions and actions were based on the specific conditions as encountered with an emphasis placed on fire ground tactical priorities (i.e., life safety, incident stabilization and property conservation);
  • Personnel had initiated fundamental measures to engage in if they were to become disoriented or trapped inside a burning building; and
  • Issued personal protective equipment was utilized in the correct manner.

In Memory

The Colerain Township (OH) Department of Fire and Emergency Medical Services’s report examined the events of April 4th, 2008 with the benefit of hindsight, while seeking to be independent, impartial, and thorough. From the beginning, Colerain Fire & EMS has been committed to share our findings with others in the hope that it may prevent another such event.

The deaths of Captain Robin M. Broxterman and Firefighter Brian Schira had a profound loss not only to their parents, family and this organization, but also to the larger fire service community. In order to prevent these tragic losses in the future, we must first understand how and why our sister and brother firefighters died. We must learn from their incident and take that knowledge forward. If it was possible, what would these firefighters tell us today that might prevent a similar death of a firefighter in the future? What would they want us as firefighters, company officers and chief officers to know about the circumstances that lead to their deaths and the things we (and they) might have done to alter the most tragic of outcomes?

From the information that was made available for review, it was evident that these two individuals were well-loved in life, and greatly missed in death. Every line of duty death of a firefighter in the United States is significant. This investigative analysis document is dedicated to Captain Broxterman and Firefighter Schira, their families, friends and the community whose lives were forever changed. In working to improve the health and safety of all United States firefighters, we have much to learn from the supreme sacrifice of these two individuals, who they were in life and in death. We honor their memories.

 

References

  • Colerain Township Department of Fire and Emergency Medical Services, Web Site HERE
  • Investigation Analysis of the Squirrels nest Lane Firefighter Line of Duty Deaths April, 2010 Full Report HERE
  • NIOSH Fire Fighter Fatality Investigation Report F2008-09| CDC/NIOSH July, 2009, Report HERE
  • WLTW.com news report Summary HERE

 

 

Thousands Honor Fallen LAFD Firefighter Glenn Allen

No comments

PHOTOGRAPH BY: Liz O. Baylen / Los Angeles Times PHOTOGRAPH BY: Liz O. Baylen / Los Angeles Times

  • Firefighters gather to honor fallen colleague, Glenn Allen, HERE
  • Glenn L. Allen was a Firefighter/Paramedic for over 36 years and last served at Fire Station 97. He is the 61st Los Angeles Firefighter to have died while directly involved in emergency operations during the Department’s 125-year history.
  • The cause of the February 16th fire remains under investigation.
  • Allen was the first Los Angeles Fire Department firefighter to be killed in the line of duty since March 2008, when Brent Louvrien died following an explosion.
  • LAFD LODD: Hollywood Hills Mansion Investigating Building Standards

PHOTOGRAPH BY: Liz O. Baylen / Los Angeles Times

Are You Prepared to PREVENT a Line of Duty Death?

No comments

Power is the ability to command or apply force.

Authority is the right to command and expend resources.

A leader is one who can generate effective individual and group action to accomplish agency goals.

The fire service is a dynamic profession that is richly steeped in tradition, noble in deeds and calling. We know the fire service to be constant – yet ever changing in today’s society. We have built this profession upon man and machinery in opposition with an uncontrolled force known as fire. The last fifteen years has shown a shift from traditional fire service missions to encompass a wide scope of service deliveries that is ever expanding. We are challenged daily on the way we do business.
These changes have affected not only the fire service as a whole but also each level
within. The importance of competencies for fire officers in skills, knowledge and training is of the essence in today’s fire service. Fire officer cultural and attitudinal changes are the crucial links that will ultimately determine the future of our business.
Each year the American fire service experiences an average of over 100 line of duty deaths each year. Further we know that the amount of working fires are down approximately 66% of what they were in the mid 1970’s. So what is the score card saying? Why do we continue to know the causes of line of duty deaths and do nothing to change? Summed up it is nothing more than attitudes. We need to change our attitudes. There is no where in the corporate world that you could come in and give an annual report that stated we had a good year, we only lost 100 employees that you would not be escorted out the door before you could get your personal items in a box. Ron Siarnicki of the national Fallen Fire Fighters Foundation (NFFF) made this statement in one of there program. Guess what…HE IS CORRECT! Why do we as leaders in this business continue to allow these issues to occur? Why do we continue to deem it an honor to die in the line of duty? Why are we so resistant to change? We call it tradition! Well as a fire chief and a fire service member I have to say, “GET OVER OLD and BAD TRADITIONS, START A SAFE NEW ONE!” Ok, if I stepped on some toes here, GOOD, they probably needed it. We cannot afford to continue allowing the same mistakes over and over again to occur. At some point we have to start saying it is not acceptable to have injuries and Line of Duty Deaths (LODD). We must change this culture and the time is now and it starts with YOU!
I recently was shuttled to the airport following a conference. I was able to spend that time talking with a young foriegn exchange fire science student who was asking many questions about the culture of the fire service. I asked me how many people get hurt or are killed doing this job as he had seen T-Shirts this week about this. I was ashamed to say we  usually have an average of more than 100 firefighters a year. He then asked why. Boy did this hit home! We know why and how firefighters die in the line of duty but what are we doing to prevent them? In 2010 we had eighty five(85) line of duty deaths. My question is just how many of these could have been prevented? One area that we know we can control the environment and have good chances of not having a line of duty death is training. But in 2010 we had 7 line of duty deaths in training. This equates to 8.2% of the total line of duty deaths for that year. Secondly responding to and returning from alarms accounted for 16 line of duty deaths or 18.8%. Deaths in crashes continue to account for a significant portion of the annual fatalities. How many of these could have been prevented? How many were not wearing their seat belts? How many was speed a contributing factor? To answer the last two questions is far too many. This can be corrected with an attitude adjustment.
Let’s look at how we can reduce these numbers. We need to first address our culture and make attitude changes. These changes need to be at all levels. We can begin this change today without problems by changing the thought process as new firefighters enter the academies across the United States. We can further push with the existing firefighters. We have to hit the dinosaurs hard because they take the new recruits freshly in the field and create dinosaur eggs that then develop into dinosaurs themselves. The year 2009 we saw a reduction in the line of duty deaths to below 100 again. Are we lucky or are we truly focusing on what the issues are. Thus the culture revolves in a vicious cycle. Ok there is the start but what do we do to impact the fire service?
We need to develop and require Comprehensive Health and Wellness Programs. These programs need to include physical conditioning, medical evaluations, and mental conditioning. With more and more firefighters perishing due to heart attacks and strokes ( 56.4%) we need to make sure that we are in the physical condition to do this job. I further think that the statistics are some what skewed. When we see LODDs of fire service personnel 65 years old or older who die after responses who did not engage in suppression activities it is being question as to where or not these individuals would have had a heart attack even if they were not on scene within that 24 hours. How many departments are providing and requiring comprehensive medical evaluations (NFPA 1582) for all of their members? If you are not, you need to look for a way to make this happen. So many times I hear of how certain medical evaluations have found members of the fire service with health issues they never knew existed. These physicals need to be annually. I recently was running a portion of a department’s physical conditioning program which was a job performance physical agility test. I found one of our more experience personnel to be hypertensive (elevated blood pressure). I refused to let him test and the department sent  him for medical evaluation. Guess what…he is alive today and has begun taking on life style changes and has medication to assist in controlling this issue. He had no symptoms of this condition and was at the potential levels for major problems. Simply as your grandmother would say, “an ounce of prevention is worth a pound of cure.”
Further we need to evaluate and support physical conditioning (NFPA 1583). These need to set personal goals as each individual is different, department goals and standards as to show everyone who performs must be able to perform at a set level. Lastly, we must have qualitative and quantitative testing of physical conditioning. Not as punishment but as a teaching tool. How many of your members can tell you exactly how long an SCBA will last when they are working at full capacity. As command officers this is important information as we work on scenes and strive to complete accountability of our personnel. More importantly it will keep our personnel safer.
We know this is one of the most stressful jobs anywhere you could travel. So just how well do we condition our folks mentally. Have you ever heard “suck it up it’s your job?” Sitting and talking with some professionals from an FDNY Engine Company they talked about and exhibited significant signs of Critical Incident Stress. This, I am sure, is compounded several times over from the events that affect the lives of these firefighters, but hey lets face facts here. These brothers are hurting and hurting bad. But have we addressed any of this, how about there families? I bet they are hurting too! So what do we do to help this problem? We must provide good Critical Incident Stress (CIS) education and coping techniques not only to the firefighters but also for their families. I know that I have done multiple programs on the east coast about this same issue, addressing firefighters and families together both the firehouse family and our true families all at the table together. This program is titled “Hearts and Sirens” and it explores CIS as it affects both the emergency services working and the family we leave at home when duty calls. My wife tells here heart felt stories of the situations she has had to live through and what helped. Basically we provide education, coping techniques and skills to deal with CIS for families. Let’s face it tough guys, even the hard core folks, struggle with all we face in this job at some point. As they face repetitive issues it becomes cumulative and eventually the levels will build up to the eruption point. This can be prevented and enhance our quality of life with just a little education and swallowing of pride on our part. Face it we are not super human, as much as we wish we were.
Training is the paramount. We must continue to enhance our training in every aspect. This includes going back to the basics. We often see in NIOSH reports where basic and routine components of our job are not performed or are contributing factors to LODD and injuries. So why can’t we do the basics? We have the mentality of hey I been there done that, I don’t need to do that anymore, I have got that down. Ok are you sure? If so show me! If you got it should not be hard or lengthy. Next we need to focus on realism. What are we truly going to face. I deal with the mentality of that wouldn’t happen to us or that’s the big city stuff it’s not going to happen here. Well, last time I checked fire did not discriminate. It does matter who you are or where you are from. Reality check… who would have thought that an aircraft with terrorists on board would crash in rural Pennsylvania. That should prove this point with enough said. We must train hard, train realistically and train often. By doing this we stoke our tool boxes with the right tools for the job.
As we train, we as leaders and trainers must make every effort to pull out the stops. We must not accept or condone any type of training environment or attitude that compromises the safety of any firefighter. We must cease pushing the envelope with cowboy tactics that only prove that you can show boat. If this is you I have a message…Your Dangerous and you need to change. We do not need to hurt or kill firefighters to have good quality training. In fact good quality training starts with no injuries and especially no deaths. In research of training line of duty deaths almost every incident could have been prevented.
In closing we must have to courage to say NO and the courage to be safe. It often is not a popular personality folks want to see, but again is it worth dieing for…Most times not! Come on folks, let’s face it, we are not doing everything correct here. We need to change and we need to change NOW!!! Do your self, your firefighters and their families a favor. Help prevent a line of duty death, change the attitudes and culture in your departments and have the courage to be safe! The families at home depend on you to be a leader and an officer. If you are not willing to do as much as possible to help with the change of the culture, do the fire service a favor, RETIRE or QUIT or RESIGN BEING AN OFFICER because you are part of the problem not part of the solution. Help us support the National Fallen Firefighters Foundation and the fire service quest of “EVERYONE GOES HOME”.

Operational Integrity and Command Fortitude

No comments

CR1999 Roger B. Conant

Today December 3, 2010 marks the 11th anniversary of the Worcester Cold Storage Warehouse fire that resulted in the line of duty death of six courages brother firefighters.

For those of you who remember this event, take the time to reflect and honor the sacrifice made this day; to those of you who have not heard about the fire before- take the time to learn about the incident, the firefighters, the building, the operational factors and challenges, the courage, fortitude and convictions that define the American Fire Service, it’s honor, tradition and brotherhood.

The Worcester Six;

  • Firefighter Paul Brotherton Rescue 1
  • Firefighter Jeremiah Lucey Rescue 1
  • Lieutenant Thomas Spencer Ladder 2
  • Firefighter Timothy Jackson Ladder 2
  • Firefighter James Lyons Engine 3
  • Firefighter Joseph McGuirk Engine

Take the time today or over the weekend to read for the first time or review both the USFA report and the NIOSH Report on the Worcester Cold Storage Warehouse fire. Start thinking about or reminding yourself what it is that we do as firefighters, fire officers and commanders.

Reflect upon the incident parameters, the building, the report and conditions upon arrival, command and operational integrity, company level responsibilities and duties, command fortitude and accountability. Think about your understanding of building construction, operational demands and training and skill set competencies.

More importantly, think about the duty, honor, courage, integrity  and sacrifice reflected in all the men and women on that day in 1999 and especially the brother firefighters who will always be known as the Worcester Six, but who were much, much more….

For a detailed overview of the Worcester Cold Storage Warehouse fire, go to Commandsafety.com HERE for a comprehensive posting.

Leading Recommendations for Preventing Fire Fighter Fatalities, 1998–2005

No comments

2009100smNIOSH issues Report on: Leading Recommendations for Preventing Fire Fighter Fatalities, 1998–2005

The United States currently depends on approximately 1.1 million fire fighters to protect its citizens and property from losses caused by fire. Each year in the United States, approximately 100 fire fighters die in the line of duty. Sudden cardiac death is the leading cause of fatalities, followed by trauma. In 1998, Congress appropriated funds to the National Institute for Occupational Safety and Health (NIOSH) for a fire fighter safety initiative. As part of this initiative, NIOSH developed and implemented the Fire Fighter Fatality Investigation and Prevention Program (FFFIPP).

The overall goal of the NIOSH FFFIPP is to reduce the number of fire fighter fatalities. To accomplish this goal, NIOSH conducts investigations of line-of-duty fire fighter deaths to identify contributing factors and to generate recommendations for prevention.

This document is a synthesis of the 1,286 individual recommendations from the 335 FFFIPP investigations conducted from 1998 to 2005. We hope that the fire service will use this document as a resource and catalyst for developing, updating, and implementing effective policies, programs, and training to prevent fatalities among fire fighters.

Executive Summary
The report document summarizes the most frequent recommendations from the first 8 years of the NIOSH Fire Fighter Fatality Investigation and Prevention Program (FFFIPP). The overall goal of the program is to reduce the number of fire fighter fatalities.

Through 2005, the FFFIPP investigated 335 fatal incidents involving 372 fire fighter fatalities. The investigations encompassed a variety of circumstances such as cardiovascular-related deaths, motor vehicle accidents, structure fires, diving incidents, and electrocutions. Fatalities have been investigated in career, volunteer, and combination departments in both urban and rural settings throughout the United States.

This document shares the most common recommendations from the 335 investigations and more than 1,286 recommendations that were developed by NIOSH investigators. These recommendations were developed using existing fire service standards, guidelines, standard operating procedures, and other relevant resources over the first eight years of the program. Fire departments can use this document when developing, updating, and implementing policies, programs, and training for fire fighter injury prevention efforts.

Download or review the NIOSH Report HERE