Skip to content


Chicago Fire Captain Herbie Johnson remembered for his kindness, humor, bravery

No comments

Captain Herbie Johnson, CFD

 

Photo By Tim Olk (all rights reserved)
http://olkee.smugmug.com/Mabas-Division-9-City-Of/CFD-Funerals/Chicago-Detment/26417819_vPkW9J#!i=2203991836&k=XDgP8TT

 

  • Chicago Tribune Photos, HERE
  • Tim Olk Photos, HERE
  • Chicago Tribune, HERE
  • “We could not be prouder of you,”  brother of fallen firefighter says Sun-Times HERE
  • See CommandSafety.com for a complete accounting of the event, HERE
  • Family of fallen firefighter: ‘A hero for our city’ from the Chicago Tribune, HERE

  • Related
  • Deadly fire on Chicago's South Side
  • PHOTOS:  Deadly fire on Chicago’s South Side

 

 

 

Photo: E. Jason Wambsgans/Chicago Tribune

 

What will define you as a Firefigher, as an Officer…as a person?

 

 

“You don’t need a last name for Herbie. Everybody knew Herbie”; Chicago Fire Capt. Herbie Johnson

No comments

Chicago firefighter Herbert Johnson, left, poses with Chicago Fire Commissioner Jose Santiago, right, after Johnson was promoted to the rank of captain. Johnson died from injuries sustained while fighting a house fire on the South Side. — Chicago Fire Department

 ”You don’t need a last name for Herbie. Everybody knew Herbie”.   A beloved firefighter, Fire officer, father and husband died in the line of duty on Friday November 2, in the City of Chicago protecting the citizens of his city working with the companies assigned to the structure fire alarm.

Chicago Captain Herbert Johnson, 54, suffered second- and third-degree burns during fire suppression operations being conducted in the attic of the residential house at 2315 West 50th Place, according to Chicago FD officials and published media reports. The 32-year veteran of the Chicago Fire Department died Friday night after he and another firefighter were injured in a blaze that spread quickly through the 2-1/2 story wood frame house. A second firefighter, FF Brian Woods was also injured and was reported in good condition at Advocate Christ Medical Center in Oak Lawn, according to a department spokeswoman, and was subsequently released. Chicago fire investigators are considering the possibility that a malfunctioning water heater sparked the fire that killed Capt. Herbert Johnson, a Fire Department spokesman said Saturday.

  • See CommandSafety.com for a complete accounting of the event, HERE
  • Family of fallen firefighter: ‘A hero for our city’ from the Chicago Tribune, HERE

Captain Johnson, was promoted from lieutenant this summer and was assigned to Engine Co. 123 in Back of the Yards Section of Chicago for the night tour but normally worked all around the City of Chicago.

Capt. Johnson from a 2006 Sun-Times photo

The following exerpt from the Chicago Tribune helps define the type of firefighter Capt. Johnson was:

http://www.chicagotribune.com/news/local/ct-met-firefighter-killed-folo-20121104,0,5331508.story

Johnson’s influence on everyone he met was visible Saturday, with shrines at the site of his death and trees in his family’s Morgan Park neighborhood decorated with purple and black bows.

A 32-year veteran of the department, Johnson volunteered in 2001 to help with rescue efforts in New York after the 9/11 attacks. As a lieutenant in 2007, he received a Medal of Honor for outstanding bravery or heroism, the state’s highest accolade for firefighters — the result, his family said, of helping rescue children the year before from a burning building on the South Side.

Friends and family remembered him mostly for his jovial personality and tender heart, a burly man with a beaming smile who once took a sewing class so he could make a First Communion dress for his daughter.

Johnson and his sister, Julie, even went to clown school together, said their brother John Johnson, a Chicago police officer. That sister, a former police officer who is now a nurse, celebrated her birthday Friday, the day of Johnson’s death, family members said.

Their father worked for the city in the Streets and Sanitation Department, John Johnson said, and their grandfathers were Chicago police officers.

The eldest of eight children, Johnson always knew he wanted to be a firefighter, said his family members, many of whom are also in public service.

“He lived for it,” brother-in-law McMahon, said.

“He died for it,” John Johnson added.

 From the Chicago Tribune (HERE);

Just like every little boy that’s grown up in the last 20 years wanted to be Michael Jordan or Brian Urlacher, every firefighter that worked with him wanted to be Herbie,” said Tim O’Brien, a spokesman with Chicago Fire Fighters Union Local 2. “You aspired to be more like him in every way of life.”

Colleagues said Johnson spent the last several years working as an instructor at the Fire Academy. Generous and kind, he never missed a Fire Department fundraising event, they said. His helpful nature also extended beyond the firehouse, friends said, through coaching youth sports and volunteering at his church parish.

He always had a funny story and often left fellow firefighters in stitches, sometimes through his own distinctive belly laugh, colleagues said.

From The Chicago Sun-Times (HERE):

“He was always a hero to us and now he’s a hero for our city,” McMahon said. “Herbie never wanted glory or notoriety. Instead, all he wanted was to make Chicago a safer place for other members of the city. So please, in Herbie’s honor, check your smoke detectors right now, give your kids a hug.”

Johnson was an easy man to know and love, said friend Tom Taff, who runs a camp for burn victims that Johnson helped support. The recently promoted captain personified joie de vivre, a man with a big laugh who drove fire engines in parades, cooked for charity ­— left an impression in the many places he offered his service.

 

Readings and Learnings

Additional Coverage and Links

  • From Chicago WGNTV, HERE
  • From the Chicago Tribune, HERE and HERE
  • From the Chicago Sun Times, HERE
  • Photo Gallery from the Sun-Times, HERE
  • Photo Gallery from the Chicago Tribune, HERE
  • Aerial Fireground Operations, Chicago ABC 7 News, HERE
  • Google Maps; StreetView Images, HERE
  • Chicago CBS, HERE
  • 2007 Illinois Fallen Firefighter Memorial and Firefighting Medal of Honor Ceremony, HERE
  • Remembering Capt. Herbie Johnson: “To Know Him, Was to Love Him” HERE

 

 

Photo Credit: Tim Olk
https://www.facebook.com/tim.olk.75
http://olkee.smugmug.com/

VISITATION: Wednesday, November 7, 2012 at St. Rita High School, 7740 S. Western from 3-9 PM.
FUNERAL MASS: Thursday, November 8, 2012 at St. Rita High School at 11:00 AM

 

 

 

Family, friends gather to mourn fallen firefighter Herbert Johnson, Chicago Sun-Times Additional Video HERE

 

Fire Dynamics Simulation of 2011 Baltimore County LODD- 30 Dowling Circle

No comments

Operations at 30 Dowling Circle 01.19.2011 Box 11-09

 On Wednesday, January 19, 2011, a fire occurred in an apartment building located in the Hillendale section of Baltimore County, Maryland. This fire resulted in the line of duty death (LODD) of volunteer firefighter Mark G. Falkenhan, who was operating as the acting lieutenant on Squad 303 . Upon their arrival, FF Falkenhan and a second firefighter from Squad 303 deployed to the upper floors of the apartment building to conduct search and rescue operations. Other fire department units were already involved with both firefighting operations and effecting rescues of trapped civilians.

During these operations, FF Falkenhan and his partner became trapped in a third floor apartment by rapidly spreading fire and smoke conditions. The second firefighter was able to self-egress the building by diving headfirst down a ladder on the front (address side) of the building. FF Falkenhan declared a “MAYDAY” and implemented “MAYDAY” procedures, but was unable to escape or be rescued.

FF Falkenhan was located and removed via a balcony on the third floor in the rear of the building. Resuscitative efforts began immediately upon removal from the balcony, and continued en route to the hospital. FF Falkenhan succumbed to his injuries and was pronounced deceased at the hospital.

Mark Gray Falkenhan had dedicated his life to serving others. He perished in the line of duty on January 19, 2011 while performing search and rescue operations at a multi-alarm apartment fire in Hillendale, Baltimore County (Maryland). He was 43 years old.

 

Firefighter Mark Falkenhan

30 Dowling Circle

 

The Baltimore County (MD) Fire Department published the Line of Duty Death Investgation Report of the 30 Dowling Circle Fire recently.

The report was written by a Line of Duty Death Investigation Team comprised of departmental members, including representatives of the local firefighters’ union and the Baltimore County Volunteer Firemen’s Association.

An overview and executive narrative of the final report (PDF) on the apartment fire where Volunteer Firefighter Mark Falkenhan sustained fatal injuries was posed on CommandSafety.com HERE.

FF Mark Falkenhan

 On Wednesday, January 19, 2011, a fire occurred in an apartment building located in the Hillendale section of Baltimore County, Maryland. This fire resulted in the line of duty death (LODD) of volunteer firefighter Mark G. Falkenhan, who was operating as the acting lieutenant on Squad 303 (for purposes of this report, Mark will be referred to as FF Falkenhan).

Upon their arrival, FF Falkenhan and a second firefighter (FF # 2) from Squad 303 deployed to the upper floors of the apartment building to conduct search and rescue operations. Other fire department units were already involved with both firefighting operations and effecting rescues of trapped civilians.

During these operations, FF Falkenhan and FF # 2 became trapped in a third floor apartment by rapidly spreading fire and smoke conditions. FF # 2 was able to self-egress the building by diving headfirst down a ladder on the front (address side) of the building. FF Falkenhan declared a “MAYDAY” and implemented “MAYDAY” procedures, but was unable to escape or be rescued.

FF Falkenhan was located and removed via a balcony on the third floor in the rear of the building. Resuscitative efforts began immediately upon removal from the balcony, and continued en route to the hospital. FF Falkenhan succumbed to his injuries and was pronounced deceased at the hospital.

The investigating team examined any and all data available, including independent analysis of the self contained breathing apparatus (SCBA), turnout gear and autopsy report. The Bureau of Alcohol, Tobacco, Firearms and Explosives (ATF) produced a fire model to assist with evaluating fire behavior. Multiple site inspections were conducted. Extensive interviews were conducted by the team which also attended those conducted by investigators from the National Institute for Occupational Safety and Health (NIOSH). Photographic and audio transcripts were also thoroughly analyzed. A comprehensive timeline of events was developed. All information used to make decisions regarding recommendations was corroborated by at least two sources.

  • In fairness to those units involved in this incident, the investigating team had the advantage of examining this incident over the period of several months. Furthermore, given the size and nature of the event, and the fact that arriving crews were met with serious fire conditions and several residents trapped and in immediate danger, all personnel should be commended for their efforts for performing several rescues which prevented an even greater tragedy.
  • The team did not identify a particular primary reason for FF Falkenhan’s death.
  • What were identified were many secondary issues involving but not limited to crew integrity, incident command, strategy and tactics, and communications.
  • These issues are identified and discussed, and recommendations are made in appropriate sections of the report, as well as in a consolidated format in the Report Appendix.

Some of the issues identified in this report may require some type of change to current practices, policies, procedures or equipment. Most, however, do not. Specifically, the analysis and recommendations regarding Incident Command and Strategy and Tactics show that if current policies and procedures are adhered to, the opportunity for catastrophic problems may be reduced.

  • Mark Falkenhan was a well-respected and experienced firefighter.
  • He died performing his duties during a very complex incident with severe fire conditions and unique fire behavior coupled with the immediate need to perform multiple rescues of victims in imminent danger.
  • It would be easy if one particular failure of the system could be identified as the cause of this tragedy.
  • We could fix it and move on. Unfortunately it is not that simple.
  • No incident is “routine”. Mark’s death and this report reinforce that fact.

On Wednesday, January 19, 2011 at 1816 hours, a call was received at the Baltimore County 911 Center from a female occupant at 30 Dowling Circle in the Hillendale section of Baltimore County. The caller stated that her stove was on fire and the fire was spreading to the surrounding cabinets. Fire box 11-09 was dispatched by Baltimore County Fire Dispatch (Dispatch) at 1818 hours consisting of four engine companies, two truck companies, a floodlight unit, and a battalion chief. All units responded on Talkgroup 1-2.

The location, approximately one mile from the first dispatched engine company, is a three story garden-type apartment complex, with brick construction and a composite shingle, truss supported roof. The fire building contained a total of six apartments divided by a common enclosed stairway in the center with one apartment on the left and one to the right of the stairs.

 

Fire Dynamics Simulation of 2011 Baltimore County LODD- 30 Dowling

Fire Dynamics Analysis and Insights

 

INTRODUCTION:

Assistance from the Bureau of Alcohol, Tobacco, Firearms and Explosives (ATF) Fire Research Laboratory (FRL) was requested for a fire at 30 Dowling Circle by the Baltimore County Fire Investigation Division (FID) through the ATF Baltimore Field Division on the night of January 19, 2011.

ATF Fire Protection Engineers were asked to utilize engineering analysis methods, including computer fire modeling, to assist with determining the route of fire spread and the events that led to the firefighter MAYDAY and subsequent Line of Duty Death.

Download the REPORT HERE

BACKGROUND:

Working closely with the Post Incident Analysis Team, the ATF Fire Research Laboratory created a computer simulation of the garden apartment building using Fire Dynamics Simulator (FDS). FDS is a computational fluid dynamics (CFD) modeling program developed by the National Institute of Standards and Technology (NIST).

FDS utilizes mathematical calculations to predict the flow of heat, smoke and other products of fire. Smokeview, a post-processer computer program also produced by NIST, was then used to visualize the mathematical output from FDS. The most current available versions of both programs were used: FDS 5.5.3 and Smokeview 5.6. Below are photographs of the front and rear of the fire building next to an image of the same building constructed in FDS.

Figure 01. 30 Dowling Street

 

Figure 2. FDS representation of the front of 30 Dowling Circle showing the terrace (T), second (A) and third (B) levels.

 

The garden apartment building at 30 Dowling Circle was attached to two similar garden apartment buildings, one on each side. The fire damage was isolated to 30 Dowling Circle, so the exposure buildings were not included in the computer fire model. The entire six unit garden apartment building was modeled in FDS, including the patio and balconies on the rear of the building. FDS works by dividing a space into cubical “grid cells” for calculation purposes. FDS then computes various CFD calculations for each grid cell to predict the movement of mass, energy, momentum and species throughout a three-dimensional space.

The Dowling Circle model consisted of 2,560,000 total grid cells that were each 3.9 inch (10 cm) cubes. The model was used to simulate a total elapsed real time of 27.5 minutes, beginning before the 911 call and ending just after flashover of the third floor and the firefighter MAYDAY.

The model was synchronized in real time with the fireground audio throughout the duration of the fire.

Fiqure 03 and 04

 

FDS has been validated to predict the movement of heat and smoke throughout a compartment, however the accuracy of fire modeling depends on it being used appropriately by a trained user that is aware of its limitations. Due to lack of knowledge about the exact material properties for the various furnishings and other available fuels, a user-specified fire progression was used for this application.

For flame and fire gas movement after consumption of the original burning fuel packages, the fire model calculated smoke and ventilation flow paths through the building and was used to gain a better understanding of the rapid fire growth leading to flashover of the stairwell and third floor.

  • In addition, FDS was utilized to illustrate the complex route of fire spread through the building as verified by witness statements, firefighter interviews, photographs and burn patterns.
  • Input data for the computer model included heat release rate data and video from previous testing conducted by the ATF FRL and NIST.
  • Ambient weather data was also input into the model, including temperature, as well as wind direction and magnitude at the time of the fire. In addition, several alternative compartmentation scenarios were modeled to explore the possible effects of closed stairway apartment entrance doors on the spread of smoke and flames in the stairwell.
  • The statements of each firefighter were reviewed and their individual actions (breaking windows, opening doors, etc.) and observations (fire size, smoke conditions, etc.) were recorded on floor diagrams.

The actions and observations of the firefighters were then associated with specific times in the fireground audio to generate an overall event timeline. All events in the model are based on this master timeline of events. In addition, all photographs were time stamped and synchronized with the model. The Post Incident Analysis Team was consulted throughout the development of the event timeline and the computer fire model to ensure accuracy.

MODELING ANALYSIS:

1. Analysis of Fire Development in the Terrace Level

The fire originated on the stovetop of an occupied apartment on the right (south) side of the terrace level (apartment T2). Flames from a grease fire ignited kitchen cabinets, eventually causing the kitchen to flashover into the attached living room. Upon fire department arrival, a fully developed fire existed in the living room and kitchen of apartment T2. Prior to exiting the apartment, the occupant opened both the rear sliding door and the apartment entrance door in an attempt to ventilate smoke from the apartment.

 

Figure 06. A typical floor plan of the right side apartments at 30 Dowling Circle.

 

An analysis of the ventilation flow path through the apartment with FDS indicated that a significant unidirectional flow path existed up the stairs with an inlet at the rear terrace sliding door and outlet at the front apartment entrance door leading to the stairwell.

Figure 7. Smokeview frame of the rear of the building indicating the fire origin and smoke spread within the T2 apartment. Figure 8. View of smoke flow out of kitchen and open sliding glass door (center of photo) in the rear of apartment T2. Figure 9. Smokeview frame of flashover of the kitchen with flames extending into the living room. Flames also begin to extend out of the rear sliding door and impact the balcony above.

 

Figure 10. Ignition of second level balcony resulting from flame extension from living room.

 

This unidirectional flow path up the stairs is difficult to combat and is often experienced during basement fires as crews attempt to descend interior stairs. The model indicates sustained air temperatures in the stairwell of approximately 600 Fahrenheit (315 Celsius) at velocities of approximately 6 mph (2.7 m/s) from floor to ceiling as crews attempted to descend the stairs. This is consistent with statements from firefighting crews, who experienced extremely high heat conditions and indicated periodically seeing flames in the smoke layer flowing up the stairs.

The elevated air velocity of the stairwell flow path resulted in a high rate of convective energy transfer to the structural firefighting gear and high perceived temperatures as the firefighters attempted to descend the stairs. Firefighting crews flowed a hoseline down the stairs to combat the high temperatures; however no significant cooling was noticed by firefighters because the hose stream could not reach the seat of the fully developed fire in the kitchen area.

The crews were simply cooling the ventilation flow path without cooling the source of the energy in the apartment. It was not until a hose stream was directed through an exterior window and a portion of the fire was extinguished that gas temperatures and velocities began to decrease, allowing firefighters to make entry to the terrace apartment via the stairs.

Figure 12. Smokeview section frame showing unidirectional flow of approximately 600 Fahrenheit (315 Celsius) gases out of the stairwell entrance door

Front photo of unidirectional flow of smoke up stairwell from apartment T2. Note the high volume of smoke from floor to ceiling as the stairwell door serves as the flow path outlet. The ground ladder in the foreground was used to rescue an occupant on the third floor trapped by heavy smoke in the stairwell. (Refer to Figure 014)

Figure 014. Front photo of unidirectional flow of smoke up stairwell from apartment T2. Note the high volume of smoke from floor to ceiling as the stairwell door serves as the flow path outlet.

 

The first arriving engine, E-11, was staffed with a Captain, Lieutenant, Driver/Operator, and a Firefighter. Upon arrival at 1820 hours, the Captain gave a brief initial report describing a three story garden apartment with smoke showing from side Alpha: “The Captain of E-11 will have Command and we are initiating an aggressive interior attack with a 1 ¾” hand line”. Command also instructed the second due engine to bring him a supply line from the hydrant. 

A female resident (victim # 1) appeared in a third floor apartment window, Alpha/Bravo side (Apt. B-1), yelled for assistance, and threatened to jump. Smoke or fire was visible from any of the third floor windows. At 1823 hours, Command advised Dispatch that he had a rescue and that he was establishing Limited Command. Fire Dispatch was in the process of upgrading the response profile to an apartment fire with rescue when the responding Battalion Chief requested that the fire box be upgraded to a fire rescue box. While the Firefighter and Lieutenant prepared for entry into the building, the Captain and Driver/Operator extended a ladder to the 3rd floor apartment window and rescued the resident. The first attempt by the Firefighter and Lieutenant to make entry into the side Alpha entrance was unsuccessful due to the extreme heat and smoke conditions.

The second due engine, E-10, arrived at 1823 with staffing of a Captain, Lieutenant, Driver/Operator, and a Firefighter. At 1823, E-10’s crew brought a 4″ supply line to E-11 from the hydrant at Deanwood Rd. and Dowling Circle and assisted the first-in crew with fire attack.

  • The Captain from E-10 conferred with Command and was instructed to advance a second 1 ¾” hand line.
  • The window to the first floor right apartment (Apt. T-2) was removed, and the second 1 ¾” line was advanced to the building by the crew of E-10.
  • Fire attack was initiated through the removed window. At 1827, Command requested a second alarm.

At this time, heat and smoke conditions just inside the front door improved enough to allow the Firefighter and Lieutenant from E-11 to make entry through the front door and into the stairwell. There they encountered heavy, thick black smoke and high heat conditions coming up the stairs from the terrace level apartment. The Lieutenant reported that the doorway to the first floor apartment was orange with fire and he had to fight his way through heavy heat and smoke conditions to attack the fire in the first floor right apartment (Apt. T-2). Entry was made approximately 3 feet into the doorway when the Firefighter’s low air alarm began to sound, and he exited the building. A member from E-10’s crew replaced the Firefighter from E-11 on the hose line.

At the same time, the Captain from E-11 proceeded to the rear of the structure to complete his initial 360 degree size up. He noted that there was fire emanating from the open sliding doors on the first floor Charlie/Delta apartment (Apt. T-2), extending to the balcony above. E-1, staffed by a Captain, Driver/Operator, and two Firefighters arrived and completed the hookup of the supply line that had been laid to the hydrant by E-10. The rest of Engine 1’s crew grabbed tools and an extension ladder and reported to the Charlie side of the building.

Figure 015 Charlie Side ( Rear) Extension

The Photo above referenced as  Figure 015 shows conditions  from rear of flames in apartment T2 and extension to the balcony above. Note the relative minimal volume of smoke as the sliding door serves as the inlet for ventilation into the apartment. The smoke and heat is flowing in from the rear, through the apartment and up the stairs.

This unidirectional flow path up the stairs is difficult to combat and is often experienced during basement fires as crews attempt to descend interior stairs.

  • The model indicates sustained air temperatures in the stairwell of approximately 600 Fahrenheit (315 Celsius) at velocities of approximately 6 mph (2.7 m/s) from floor to ceiling as crews attempted to descend the stairs.
  • This is consistent with statements from firefighting crews, who experienced extremely high heat conditions and indicated periodically seeing flames in the smoke layer flowing up the stairs.
  • The elevated air velocity of the stairwell flow path resulted in a high rate of convective energy transfer to the structural firefighting gear and high perceived temperatures as the firefighters attempted to descend the stairs.

Firefighting crews flowed a hoseline down the stairs to combat the high temperatures; however no significant cooling was noticed by firefighters because the hose stream could not reach the seat of the fully developed fire in the kitchen area.

The crews were simply cooling the ventilation flow path without cooling the source of the energy in the apartment.

It was not until a hose stream was directed through an exterior window and a portion of the fire was extinguished that gas temperatures and velocities began to decrease, allowing firefighters to make entry to the terrace apartment via the stairs.

Plan view of flow path and temperatures within the apartment. Note the location of the seat of the fire and the location of initial hose stream application down the stairs.

Figure 016

 

Photograph of hoselines being positioned at the stairwell entrance door and front window. Note the heavy smoke venting from all front openings in apartment T2. (Figure 017)

Figure 017 Alpha Side Entry Door

 

Figure 017  Hoselines being positioned at the stairwell entrance door and front window. Rapid Fire Progression Leading to Flashover of the Third LevelFlames extended upwards from the T2 apartment sliding door and ignited the rear balconies of the second and third level apartments above.
 
Fire on the second floor balcony extended into apartment A2 by failing the sliding glass door and igniting vertical plastic slat curtains that were suspended above.As crews searched within the second floor apartment, they noted seeing the burning curtains on the floor with flames extending to a nearby couch (containing polyurethane foam padding) adjacent to the sliding doorway.
 
The fire continued to grow unsuppressed and spread to a second couch as interior firefighting crews were engaged in rescuing two victims from the living room in the second floor apartment.Personnel stated that at this point fire conditions seemed to improve, suggesting that crews were making progress extinguishing the fire. (The first arriving attack crew reported that they were able to see apparatus lights through the sliding doors on Charlie side, which indicated to them that smoke and fire conditions were improving.)Truck 1, a tiller unit staffed by a Lieutenant, two Driver/Operators, and a Firefighter, arrived on side Alpha and immediately began search and rescue operations.
 
Windows on the second floor Alpha/Delta side apartment (Apt. A-2) were vented and ladders were thrown to gain access. T-8 arrived at the alley on side Charlie. E-1 extended a ground ladder to the third floor balcony on the Charlie/Bravo side of the structure (Apt. B-1), and made access to the apartment to search for additional victims.They noted fire venting from the first floor Charlie/Delta apartment (Apt. T-2) out of the sliding glass doors progressing upwards towards the balcony on the second floor.
 
Upon entering the apartment, they conducted a primary search and noted minimal heat with light smoke conditions.The crew accessed the hallway via the apartment entry door and noticed an increase in the temperature and the amount of smoke.They immediately closed the door and exited the apartment via the ground ladder.Upon exiting the apartment, E-1’s crew observed E-292 on the scene with a hand line extending into the apartment of origin, (first floor, Charlie/Delta side, Apt. T-2).
 
The officer on E-1 noted white smoke coming from the unit.Having already laid a supply line from the intersection of the alley and Deanwood Road, E-292’s crew extended a 1 ¾” hand line into the apartment of origin. Moderate fire conditions with zero visibility were encountered, and they reported feeling a great deal of heat on their knees as they crawled through the apartment.The Lieutenant and the Firefighter from Truck-1 entered Apartment A-2 via a second floor bedroom window (Alpha/Delta side) and began a search for additional victims. As they traversed the living room area they found an unconscious male resident (victim #2).
 
At 1836 hours, the Lieutenant notified Command via an urgent transmission that a victim had been located and they needed assistance with evacuation. The Lieutenant and Firefighter noted a small fire in the rear corner near the victim as they exited the room. The crew returned to the bedroom from which they had entered and closed the door behind them. Victim #2 was then evacuated from the apartment via a ground ladder through the bedroom window, and transferred to EMS personnel on side Alpha.
 
Figure 019 Flame extension and suppression efforts at the rear of the structure. Flames caused the second level glass slider to fail and ignite plastic curtains in the doorway located
 

Figure 019

 
 

The middle level apartment (A2) entrance door was opened by a second search crew around the same time as the second couch ignited, creating a ventilation flow path from the second floor balcony, through the apartment, and upwards into the stairwell (third floor). This flow path follows the same general route through the apartment and into the stairwell as was seen in the terrace level apartment below. Squad 303’s crew arrived on scene after the bulk of the fire in the terrace level apartment had been suppressed and appeared to be under control. The crew entered the front stairwell, which had minimal smoke up to the second level and the crew began to systematically search the building.

Squad 303’s crew proceeded to search two apartments before entering the third floor right side apartment to conduct a search, leaving the entrance door open. It should also be noted that carpeting impacted the bottom of the door and prevented the apartment entrance doors on the second and third levels from closing automatically. The entry doors had to be actively pushed closed to overcome the friction of the carpet.

 

Photo depicting building smoke and fire conditions around the arrival of Squad 303.

Note the lack of heavy smoke or fire in the stairwell or terrace level.

There is also no indication of the growing fire in the second (middle) level apartment.

 

 

 

When Squad 303’s crew of two firefighters entered the third level apartment (B2), smoke was banked about halfway down the walls with moderate visibility. The crew could clearly see the floor of the apartment without the need to crawl below the smoke layer to search. Squad 303’s crew was unaware of the flames spreading across the two couches in the second floor apartment below them. The crew split in order to search the apartment faster, with one firefighter searching the front bedrooms and the officer searching the kitchen and living room.

As flames in the second level began to rollover into the apartment entranceway, the smoke layer in the third level quickly dropped to the floor with a rapid increase in temperature. With Squad 303’s crew searching above, flames began to extend into the stairwell, supplied by sufficient ventilation flowing through the apartment. This combination of fuel, heat and oxygen rich fresh air resulted in a rapid increase in heat release rate and flashover of the second level apartment followed by full room involvement.

The open entrance doors on the second and third levels created a ventilation flow path through the second floor apartment, into the sealed stairwell and up through the third floor apartment directly above. The flames followed this flow path and extended from the second floor, through the stairwell and into the living room area of the third floor apartment. Flashover of the third floor occurred approximately 30 seconds after the second floor experienced flashover.

Figure 026 and 027

 

Rollover from the second level apartment into the stairwell.

 

 
 
Flames followed the ventilation flow path and extend into the third floor apartment, resulting in ignition of the couches just inside the doorway.

 

 

    

 

Command sounded the building evacuation tones as flames extended into the hallway and up to the third level apartment.

Two couches just inside the entrance door on the third level ignited, blocking the primary means of egress for both firefighters from Squad 303. Upon hearing the evacuation horns from the trucks, the second firefighter from Squad 303 (searching the front bedrooms) attempted to exit the apartment via the apartment entrance door, however he was blocked by flames in the living room and stairwell.

Trapped in the bedroom, the firefighter bailed out headfirst down a ground ladder on the front side from the third floor. Squad 303 officer’s means of egress through the apartment entrance door was also blocked by the flames in the living room and stairwell. There were no windows located in the rear of the apartment.

The only means of escape was the balcony slider, however the entire balcony was engulfed in flames from the fully involved apartment below. With both escape routes blocked by flames and experiencing extremely high heat conditions, Squad 303’s officer requested assistance and declared a MAYDAY from the rear of the third floor apartment.

Firefighters re-entered the structure to combat the fire and locate the trapped firefighter. The downed firefighter was eventually located on the third level just inside the sliding glass door and was removed to the rear balcony. The firefighter was then extricated in a stokes rescue basket down the aerial ladder of a truck located in the rear, where he was subsequently transported to the hospital.

Effects of Compartmentation on Fire Spread

The Post Incident Analysis Team requested that alternate modeling scenarios be conducted to explore the effects of compartmentation on fire spread throughout the building.

The team specifically wanted to know how the ventilation flow paths through the stairwell would differ if the second or third level apartment entry doors were shut after entering/leaving the apartments. Two alternate computer fire modeling scenarios were conducted.

The first alternative modeling run featured the exact same fire scenario, except the second (middle) level apartment door was closed after the last victim was removed from that apartment. The apartment entry doors from the stairwell were fire-rated doors constructed of solid wood.

  • As soon as the door is shut, the ventilation flow path through the apartment and up the stairwell is blocked.

 

Shutting the second level apartment door blocks the flow path and flame extension into the stairwell. 

Even with the third floor apartment door left open, the model indicates that the stairwell and third floor remain tenable for firefighters. Flames eventually extend from the third floor balcony into the apartment, however the escape routes through the stairwell and the front apartment windows are accessible.           

The model indicates that closing the second level apartment door prevents the flow of smoke, heat and other products of combustion from entering the stairwell, thus preventing flashover of the stairwell and the third level. As long as the second floor entry door remains shut, the model indicated that the conditions within the stairwell and third floor remain tenable for firefighters, even with the third floor apartment door open.

A second alternative modeling scenario was conducted where the third level entrance door was closed after crews made entry to search the apartment.The same fire conditions from the actual model were used.When the door remained closed, the outlet of the ventilation flow path was blocked at the top of the stairs. Without a complete flow path, there wasn’t sufficient oxygen flowing through the second floor apartment to support extended burning in the stairwell.

Consequently after flashover of the second floor, the flames in the stairwell only exist momentarily before consuming all available oxygen and becoming ventilation limited.The fire model indicated that temperatures within the third floor apartment stayed tenable for firefighters, even with a fully developed fire on the second floor and flames in the stairwell.

Flames would eventually extend up the rear balcony to the third level, however they would not block egress through the living room and front windows of the apartment.By closing the apartment door on the third floor and blocking the outlet for fire gases emanating from the second floor apartment, the third floor apartment remains tenable for firefighting crews and the temperatures only briefly spike in the stairwell before the fire becomes ventilation limited.The ventilation flow through the apartments results in an increased burning rate within both the second and third levels, as well as the stairwell.                     

Results of each modeling scenario describing extent of flame spread

Results of each modeling scenario describing extent of flame spread.

 
 
 
 
 
 
 
 
 
 
The Effects of Compartmentation on Fire Damage to the StructureThe impact of compartmentation on fire and smoke spread is evident by examining the post-fire damage throughout the structure. While other factors contributed to the relative fire damage, including fire department overhaul and relative apartment configuration, analyzing the damage to the building and the position of the apartment entry doors provides insight on the benefits of compartmentation.

By closing apartment unit entrance doors and interior hollow core doors, one can slow or even block the ventilation flow path through the structure, thus significantly reducing the rate of fire spread. The photos below represent the post-fire damage in all six apartments within the fire building. Four of the six apartment entry doors were open for the majority of the fire and the relative difference in damage is clearly evident.

Terrace level stairwell landing looking into T1 (left) and T2 (right) apartments.

 

Door Closed……Door Open

 

 

Using doors to compartmentalize and limit fire and smoke spread in a structure is not limited to fire-rated entrance doors. Interior hollow core doors also offer considerable protection for compartmentation purposes.

A search crew utilizing the Vent, Enter and Search (VES) technique through a front window used a hollow core bedroom door to isolate themselves from the developing fire in the living room of apartment A2.

As the crews removed the second victim from the living room to the bedroom, they shut the bedroom hollow core door behind them.

The living room soon experienced flashover followed by full room involvement, however the bedroom remained isolated from the heat and smoke for the duration of the fire. The photos below illustrate this effective use of compartmentation to protect firefighters during a search.

 
Controling the Doors during VES

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
SUMMARY:
While no fire model will exactly replicate a fire, this model provided insight on the route of fire spread, the rapid fire growth leading to flashover of the second and third level, and the benefits of compartmentation on slowing fire and smoke spread.
  • The unidirectional flow path up the stairs from the terrace level apartment resulted in a high rate of convective heat transfer to the firefighters initially attempting to descend the stairs, making attacking the seat of the fire very difficult.
  • The model then supported the fact that the main stairwell acted as an open channel for fire and smoke spread between the second and third levels, resulting in flashover of the third level in approximately 30 seconds after the second level.
  • This rapid fire growth leading to flashover is supported by photographs, witness statements and fireground audio.
  • The model was then utilized to explore the effects of compartmentation using apartment entrance doors.
  • The FDS model supported the scene observations and indicated that shutting the entrance doors blocked the flow of buoyancy driven fire gases through the structure, ultimately preventing fire extension to the third floor apartment via the stairwell.
  • The FDS model was utilized as part of the overall engineering analysis of this tragic fire and allowed for a better understanding of the events that led to the firefighter MAYDAY and subsequent Line of Duty Death.
  • The model was also used as an educational tool providing insight on potential methods of preventing similar tragedies in the future.
  • The results of this engineering analysis are intended to be reviewed by the Post Incident Analysis Team to assist in the creation of recommendations to mitigate the danger associated with future fire incidents.

References:

The Ides of March: Learning and Remembrance

No comments
 
Operational Safety

Here are five (5) NIOSH Firefighter LODD Event report summaries for incidents that occurred in the March 4th through the 8th time frame in the years 1998, 2001, 2002, 2008.

Take the time to look over the event summaries, discuss and comment on the factors that lead to the events and the recommendations formulated from the subsequent investigations.

Take the opportunity to identify the common themes and apparent causes that were identified and discuss with your company, team or station, relevant considerations that may have a direct or indirect relationship to your organization, past incident calls or district risk profile.

What are your capabilities?

What are your gaps?

How can you prevent a similar situation from occurring?

Promote questions and dialog related to operational issues such as these;

  • Coordinated multi-company operations; how “coordinated” is your incident scene?
  • Do rapidly changing incident conditions get identified promptly and communicated to Command in rapid succession for actions?
  • How effective is the base line knowledge and skill set of company and command officers in “reading the building”?
  • What is the adequacy of your training for conducting operations above the fire floor?
  • When was the last time you “tested” the effectiveness of your RIT/FAST Team? Can they truly perform under the most demanding of incident conditions?
  • When was the last time you trained or drilled on Fire Behavior or on Building Construction?
  • Are you training on calling the mayday and personal survival techniques?
  • Have you implemented and trained on procedures for rapid and efficient transition in operational modes on the fireground?
  • Do you implement a 360 when applicable and delegate when needed?
  • What parameters are you operating under when assuming risk on the fireground?
  • What drives your incident operations: Are they Tactically Drive or Risk Managed?

Down load the complete NIOSH Reports and expand on the lessons learners and their applicably to your organization and capabilities.

Manlius, New York

Floor Collapse and Fire Conditions:
On March 7, 2002, a 28-year-old male volunteer fire fighter and a 41-year-old male career fire fighter died after becoming trapped in the basement. One firefighter manned the nozzle while second firefighter provided backup on the handline as they entered the house. After entering the structure, the floor collapsed, trapping both victims in the basement.

A career fire fighter captain joining the fire fighters near the time of the collapse was injured trying to rescue one of the fire fighters. Crew members responded immediately and attempted to rescue the victims; however, the heat and flames overcame both victims and eliminated any rescue efforts from the garage entrance.

NIOSH investigators concluded that, to minimize the risk of similar occurrences, fire departments should;

  • Ensure that the Incident Commander is clearly identified as the only individual responsible for the overall coordination and direction of all activities at an incident
  • Ensure that the Incident Commander conveys strategic decisions to all suppression crews on the fireground and continually reevaluates the fire condition
  • Ensure that Incident Command conducts an initial size-up of the incident before initiating fire fighting efforts and continually evaluates the risk versus gain during operations at an incident
  • Ensure that fire fighters from the ventilation crew and the attack crew coordinate their efforts
  • Ensure that fire fighters report conditions and hazards encountered to their team leader or Incident Commander
  • Ensure fire fighters are trained to recognize the danger of operating above a fire

NIOSH REPORT: http://www.cdc.gov/niosh/fire/reports/face200206.html

Wall Collapse and Fire Conditions
On March 7, 2008, two male career fire fighters, aged 40 and 19 were killed when they were trapped by rapidly deteriorating fire conditions inside a millwork facility in North Carolina. The captain of the hose line crew was also injured, receiving serious burn injuries.

The victims were members of a crew of four fire fighters operating a hose line protecting a firewall in an attempt to contain the fire to the burning office area and keep it from spreading into the production and warehouse areas. The captain attempted to radio for assistance as the conditions deteriorated but fire fighters on the outside did not initially hear his Mayday. Once it was realized that the crew was in trouble, multiple rescue attempts were made into the burning warehouse in an effort to reach the trapped crew as conditions deteriorated further.

Three members of a rapid intervention team (RIT) were hurt rescuing the injured captain. One firefighter was located and removed during the fifth rescue attempt. The second firefighter could not be reached until the fire was brought under control.

The fourth crew member had safely exited the burning warehouse prior to the deteriorating conditions that trapped his fellow crew members. Key contributing factors identified in this investigation include radio communication problems (unintelligible transmissions in and out of the fire structure that may have led to misunderstanding of operational fireground communications), inadequate size up and incomplete pre-plan information, a deep-seated fire burning within the floor of the office area that was able to spread into the production and warehouse facility, the procedures used in which operational modes were repeatedly changed from offensive to defensive, lack of crew integrity at a critical moment in the event, and weather which restricted fireground visibility.

NIOSH investigators concluded that, to minimize the risk of similar occurrences, fire departments should:

  • Ensure that detailed pre-incident plan information is collected and available when needed, especially in high risk structures
  • Limit interior offensive operations in well-involved structures that are not equipped with sprinkler systems and where there are no known civilians in need of rescue
  • Develop, implement, and enforce clear procedures for operational modes. Changes in modes must be coordinated between the Incident Command, the command staff and fire fighters
  • Ensure that Rapid Intervention Crews (RIC) / Rapid Intervention Teams (RIT) have at least one charged hose line in place before entering hazardous environments for rescue operations
  • Ensure that the incident commander establishes the incident command post in an area that provides a good visual view of the fire building and enhances overall fireground communication
  • Ensure that crew integrity is maintained during fire suppression operations
  • Encourage local building code authorities to adopt code requirements for automatic protection (sprinkler) systems in buildings with heavy fire loads.

NIOSH REPORT http://www.cdc.gov/niosh/fire/reports/face200807.html

Floor Collapses in Residential Fire - North Carolina

 

Floor Collapse
On March 4, 2002, a 22-year-old male career fire fighter was injured and subsequently died and a 25-year-old male Captain was injured when the floor collapsed while they were fighting a residential fire.

The Captain was transported by ambulance to an area hospital where he was admitted overnight for first- and second-degree burns. The victim was conscious and was transported by medical helicopter to a State medical center where he died 2 days later.

NIOSH investigators concluded that, to minimize the risk of similar occurrences, fire departments should;

  • Ensure that each Incident Commander conducts a size-up of the incident before initiating fire-fighting efforts, after command is transferred, and continually evaluates the risk versus gain during operations at an incident
  • Ensure fire fighters are trained to recognize the dangers of searching above a fire
  • Ensure that an Incident Safety Officer, independent from the Incident Commander, is appointed
  • Ensure that ventilation is closely coordinated with fire attack
  • Ensure that a Rapid Intervention Team is established and in position immediately upon arrival
  • Ensure that adequate numbers of staff are available to operate safely and effectively

NIOSH REPORT http://www.cdc.gov/niosh/fire/reports/face200211.html

 

Fall Through Floor Fighting a Structure Fire at a Local Residence - Ohio

 

Floor Collapse
On March 8, 2001, a 38-year-old male career fire fighter fell through the floor while fighting a structure fire, and died 12 days later from his injuries. At 1231 hours, Central Dispatch notified the career department of a structure fire with reports of the occupants still inside. The Assistant Chief arrived on the scene along with Engine 70 and assumed Incident Command (IC).

The IC immediately called for the second alarm, began conducting the initial size-up of the structure, and confirmed heavy fire in the left front section. At that time, the neighbors approached the IC and informed him that the occupants were trapped inside. The IC ordered the fire fighters on scene to commence search and rescue efforts, and then verified the stability of the structure through radio and face-to-face communications.

Engine 68 arrived on the scene at approximately 1250 hours with an Assistant Chief and the victim. The Assistant Chief provided tactical command of the fire ground, and along with the victim, conducted search and rescue operations. Other crews conducted searches with a thermal imaging camera of the first floor and basement level of the residence with no sign of any occupants. During these searches the stability of the structure was diminishing due to the intense fire that was now venting through the roof.

Fire fighter #3 and the victim were at the front entrance conducting a defensive attack as the third emergency evacuation signal was sounded. The neighbors were still insisting to the IC and fire fighters that the occupants were trapped inside, and one of the occupants was handicapped. The victim and one other fire fighter conducted another search of the structure.

The heat and flames were now extending from the basement level to the first floor when the fire fighter’s low air alarm sounded. The victim and the fire fighter were backing out of the structure when the floor beneath the victim gave way, causing him to fall through the floor and become trapped in the basement.

Attempts were made from the first floor to rescue the victim by utilizing a handline and an attic ladder, but they were unsuccessful due to the intense heat and flames. Two Rapid Intervention Teams (RIT #1 & RIT #2) were deployed simultaneously from separate entrances into the basement to perform a search and rescue operation for the downed fire fighter. The RITs were able to locate and remove the victim on their initial entry. He sustained third degree burns to over half of his body and died 12 days later.

NIOSH investigators concluded that to minimize the risk of similar occurrences, fire departments should;

  • Ensure that Incident Command continually evaluates the risk versus gain during operations at an incident
  • Ensure that a separate Incident Safety Officer independent from the Incident Commander is appointed
  • Ensure that fire fighters are trained in the tactics of defensive search
  • Ensure that fire fighters performing fire fighting operations under or above trusses are evacuated as soon as it is determined that the trusses are exposed to fire
  • Ensure consistent use of Personal Alert Safety System (PASS) devices at all incidents and consider providing fire fighters with a PASS integrated into their Self-Contained Breathing Apparatus which provides for automatic operation
  • Ensure that personnel equipped with a radio, position the radio to receive and respond to radio transmissions

NIOSH REPORT: http://www.cdc.gov/niosh/fire/reports/face200116.html

 

Roof Collapse and Fire Conditions
On March 8, 1998, one male fire fighter, the Captain on Engine 57, died while trying to exit a commercial structure after his egress was cut off by the wooden trussed roof that collapsed. Task Force 66 was the first on scene and reported light smoke showing from a one-story commercial building. A ventilation team from Truck 66 proceeded to the roof of the building and commenced roof ventilation. Forcible entry into the building required about 7 ½ to 9 ½ minutes from arrival on scene to force open the two metal security doors in the front. While fire companies waited for the security doors to be opened, fire conditions changed dramatically on the roof.

Fire was coming from the ventilation holes opened by the ventilation crew. As soon as the security doors were opened, three engine crews (Engine 66, Engine 57, and Engine 46) advanced hand lines through the front door in an attempt to determine the origin of the fire. Approximately 15 feet inside the front door, the fire fighters encountered heavy smoke with near zero visibility conditions. The engine crews advanced their hose lines approximately 30 to 40 feet inside the building.

As conditions continued to deteriorate inside the building, the members from the four engine companies involved in the fire attack began to withdraw. During this time the victim became separated from his crew and remained in the building. The victim was subsequently located by the Rapid Intervention Team and cardiopulmonary resuscitation was performed immediately and en-route to the hospital, where the victim was pronounced dead.

NIOSH investigators conclude that, to prevent similar occurrences, fire departments should:

  • Ensure that incident command conducts an initial size up of the incident before initiating fire fighting efforts, and continually evaluate the risk versus gain during operation at an incident
  • Ensure that incident command always maintains close accountability for all personnel at the fire scene
  • Ensure communications are established between the interior and exterior attack crews, e.g., the ventilation crew and the interior fire attack crew should communicate conditions among themselves and back to incident command
  • Ensure that Rapid Intervention Teams are in place before conditions become unsafe
  • Ensure that some type of tone or alert that is recognized by all fire fighters be transmitted immediately when conditions become unsafe for fire fighters
  • Ensure sufficient personnel are available and properly functioning communications equipment are available to adequately support the volume of radio traffic at multiple-responder fire scenes
  • Consider placing a bright, narrow-beamed light at the entry portal to a structure to assist lost or disoriented fire fighters in emergency egress.

NIOSH REPORT: http://www.cdc.gov/niosh/fire/reports/face9807.html

 

Taking it to the Streets on Firefighternetcast.com

Taking it to the StreetsTM

Download the program from March 16th, 2011  Program

Featured a two part program on Near Miss Firefighter Reporting with Lt. Steve Mormino, FDNY (ret) and Capt. CJ Haberkorn, Denver (CO) Fire Department and  special guest, Captain Michael Long, who provided a personal Near-Miss Event account you won’t want to miss.

Check out the latest downloads of recent programs in the archives by visiting Taking it to the Street’s webpage on Firefighternetcast.com or for program insights at CommandSafety.com.

  • Download the program from March 16th, 2011  Program on Firefighternetcast.com HERE
  • Taking it to the Streets Radio Programs, HERE and HERE

Taking it to the StreetsTM is a monthly radio show featured on BlogTalk Radio and is hosted by Christopher Naum and is a Buildingsonfire.com Series and FireFighternetcast.com Production, © 2010-2012 All Rights Reserved

Mayday and Rapid Intervention Realities: The Phoenix Perspective

1 comment

 

Southwest Supermarket Fire March 14, 2001

This year’s Fire/EMS Safety, Health and Survival Week focused on Surviving the Fire Ground: Fire Fighter, Fire Officer and Command Preparedness. One of the major objectives of this year’s theme was addressing a variety of functional areas for the Mayday event. For many of you, the conditions, outcome and lessons learned from the Southwest Supermarket Fire, maydays and the Line of Duty Death of Phoenix (AZ) firefighter Bret Tarver in 2001 are as fresh today as they were ten years ago and certainly as relevant as when many of us first read the Final Report issued by the Phoenix FD.

However, to many others in the Fire Service the Bret Tarver LODD and the Southwest Supermarket fire along with the lessons learned that were identified and the research that was instituted may not have made it onto your radar screen. In this the final days of the 2011 Fire/EMS Safety week, it is very appropriate to provide some insights on this mayday event and more importantly provide you with the opportunty to learn from the past, to understand operational parameters, capabilites, fallacies, misconceptions and limitations when we talk about Mayday, RIT and FAST activities and operational deployments.

Here’s an overview of the event;

On March 14, 2001 the Phoenix (AZ) Fire Department lost firefighter Brett Tarver at the Southwest Supermarket fire.

In that event, it was 5:00 in the afternoon, the grocery store was full of people and fire was extending through the building. Phoenix E14 was assigned to the interior of the structure to complete the search, get any people out, and attempt to confine the rapidly spreading fire to the rear of the structure. Shortly after completing their primary search of the building the Captain decided it was time to get out. Tarver and the other members of Engine 14 were exiting the building when Tarver and his partner got lost.

The engineer (driver) was leading the group following the attack line they had brought into the supermarket fire, followed by Tarver and his partner, with the company officer being the last person to begin the long crawl out of the smoke filled structure. At some point Tarver and his partner got off the hose line and moved deeper in the supermarket fire away from their only exit. Early on during the exit attempt through maze like conditions Tarver and his partner basically turned left instead of right. Not knowing this the company officer continued to crawl out of the building thinking his whole crew was ahead of him on the attack line. Tarver and his partner crawled deeper into the fire occupancy eventually ending up in the butcher shop area where they eventually became separated.

Based on radio reports of deteriorating conditions inside the building from E14 and other companies the Incident Commander (IC) considered a switch to a defensive strategy and started the process of pulling all crews out of the structure. During this process Tarver radioed the IC telling him that he was lost in the back of the building. The IC deployed two companies as Rapid Intervention Crews (RICs) through the front access point to no avail.
Other companies coming to their rescue through the back room area of the supermarket later rescued Tarver’s partner. After several unsuccessful rescue attempts, Tarver succumbed to carbon monoxide poisoning from the acrid smoke and was eventually removed from the building as a full code. Trying to remove the 260-pound firefighter was nearly impossible for rescue team members. Outside, the resuscitation efforts failed.

During the rescue efforts there were more than twelve (12) mayday’s issued by firefighters trying to make the rescue. On this tragic day, one other firefighter (attempting to rescue Tarver) was removed in respiratory arrest and was later resuscitated by fire department paramedics on the scene.

Over the next year (The Recovery), the department systematically reviewed its standard operating procedures and fireground operational activities at the strategic (command), tactical (sector) and task (company) levels of the entire organization in an attempt to prevent such a tragic event from ever happening again to the Phoenix Fire Department. One of the many significant questions that was asked was why didn’t the rapid intervention concept work? Immediately after the fire the Phoenix Fire Department reviewed its Rapid Intervention and Mayday standard operating procedures (SOPs). Based on drills, training and the data acquired through those drills, in the year following the incident the standard concept of a rapid intervention is now being challenged.

It is now evident that rapid intervention isn’t rapid. (Reference: Excerpts from the original article by Steve Kreis and FireTimes.com, LLC. http://www.firetimes.com/printStory.asp?FragID=8399 )

In the wake of the 2001 Southwest Supermarket Fire and LODD of FF Brett Tarver, the Phoenix (AZ) Fire Department issued a comprehensive report of the incident and the lessons learned and research conducted by the FD.

Beyond 2011 Fire/EMS Safety, Health and Survival Week; Fire Fighter, Fire Officer and Command Training and Preparedness

  • If you have never heard about the Southwest Supermarket Fire and the Bret Tarver LODD and incident and never read the report;
    • take the time to do so and understand that the concepts of RIT and FAST are made up of far more elements, considerations and more importantly realities of what you think you can do versus what you may actually be able to do.
    • if you’ve read it in the [past], take a few minutes to review and refresh;
    • see where your organization, department and RIT/FAST training and capabilities are today-
    • what are the capabilities of your fire fighters, officers and commanders?
  • Take a look at the NIOSH report and the recommendations contained; how does your deparment stack up today?
  • After reading the reports, take a close look at your organization, your personnel and your training and your capabilities and
  • ask yourself if you are truly able to perform the necessary RIT/FAST operations or
  • do you have a ways to go to better prepare, train and ensure you’re able to undertake the job and address the fireground survival needs when a mayday is called.
  • did you take the time during this safety week to make some progress, identify some new insights, gaps or renewed interests and desire to enhance on your capabilities and strengths?
  • Are your Mayday, RIT and FAST capabilites, skills and knowledge better today in 2011 than they were in 2001?

 

References:

The following is an article piece posted by my good friend Mike Ward and posted a number of years ago from www.thewatchdesk.com written by: Mike Ward

Rapid Intervention Reality – from Phoenix
 

Subject: Rapid Intervention Reality Check By Michael Ward   

The Phoenix Fire Department’s Deployment Committee has a sobering message to their firefighters operating in large buildings, like a 7,500 square foot warehouse: “If you extend an attack line 150′, get 40 feet off the line and then run out of air, it will take us 22 minutes to get you out of the structure.” The lesson to remember is not to get off the fire attack line.  The statement is based on 200 rapid intervention drills conducted by PFD as part of their recovery process after Firefighter/paramedic Brett Tarver  died in the March 14, 2001 Southwest Supermarket fire.

PFD obtained three vacant commercial buildings: a warehouse, a movie theatre and a country-western bar. The RIT drill was for the first alarm companies to respond to a report of two firefighters in trouble. One is disoriented and the other one is unconscious. The buildings were sealed from outside light and the facemasks were obscured to simulate heavy smoke conditions. The RIT teams were equipped and deployed as if this is was a working fire. The department ran through about 200 RIT drills with 1144 PFD firefighters participating. Their activities were monitored and timed. An Arizona State University statistician analyzed the data.

The results show that rapid intervention is not rapid:

  • Rescue crew ready state 2.50 minutes
  • Mayday to RIC entry 3.03 minutes
  • RIC contact with downed firefighter 5.82 minutes
  • Total time inside building for each RIC team 12.33 minutes
  • Total time for rescue 21 minutes

The evolutions also revealed three consistent ratios:

  • It takes 12 firefighters to rescue one
  • One in five RIC members will get into some type of trouble themselves.
  • A 3000-psi SCBA bottle has 18.7 minutes of air (plus or minus 30%)
     

The results of the RIC drills reflects the experience Phoenix had during the efforts to rescue Firefighter/paramedic Brett Tarver. There were a dozen maydays sounded during the rescue effort, and one PFD firefighter was removed from the supermarket in respiratory arrest.

The Phoenix experience is not unique. Houston Fire Chief Chris Connealy participated in a discussion about the Phoenix RIC drills during the 2003 Change in the Fire Service Symposium. On October 13, 2001, Houston Engine 2 Captain Jay Jahnke died on the fifth floor of Four Leaf Towers, a 41 story residential high-rise. During the Houston RIC operation, two heavy rescue company firefighters became disoriented, low on air and had to rescue themselves. An engine company captain and firefighter run out of air and collapsed on the fire floor. Chief Connealy said that the Houston experience is similar to Phoenix.

Phoenix is changing its approach to rapid intervention crews in three procedural ways: increase suppression units assigned to RIC, increased in command officers, and considering a two-part RIC process.

There is a scalar approach to RIC dispatch assignments in Phoenix. For a “3-1 Assignment” (three engines and one ladder), a fourth engine and an ems transport (rescue) is added to the assignment to function as the rapid intervention team. For a 1st alarm assignment, two engines, one ladder, one rescue and a battalion chief are the RIC team. A second alarm includes an additional two engines and ladder for RIC. Beyond a second alarm, the incident commander can call additional companies as needed.

The recovery process also looked at the utilization of company and command officers on the fireground. A company officer core competency is to command a fire company. A core chief officer competency is to command fire companies. It is a function of the fire department hierarchical structure, not of personality.  For example, a captain filling-in as a battalion chief does a better job as a West Sector officer than she would have if she was commanding Engine 2 AND in charge of West Sector. At the sector level of the incident management system, company officers are required to wear two hats. There are too many levels of tasks. Phoenix suggests that it would be more effective to send more command officers to a fire event to function as sector and division commanders and allow the company officers to command their companies. It is a waste of talent and experience to allow command officers to stay in their fire stations while a low-frequency, high risk event like a structure fire is occurring
in the city.

A third change in rapid intervention crews is using a two-phase approach.  Many of the RIC team members ran out of air during the training evolutions.  The drills showed that a 3000-psi SCBA bottle was good for 13.09 to 24.31 minutes of air. The average SCBA time was 18.7 minutes. The average time from mayday to removal was 21 minutes. RIC teams were running out of air during the firefighter removal phase. In addition, it was taking a crew of 12 firefighters to remove one firefighter. Phase one of a RIC response is to send a team in to locate the firefighters in trouble. Once located, a second RIC team enters to remove the firefighter.

You are welcome to share this with everyone. Please include the following: taken from www.thewatchdesk.com written by:
Michael Ward, Fire Science Program Head, Northern Virginia Community College.  

 

 Other recent postings and references from CommandSafety.com

Day One: Fire/EMS Safety, Health & Survival Week 2011: Day One- Are You Ready?

Day Two: Fire/EMS Safety, Health and Survival Week: Day Two- Building Knowledge = Fire Fighter Safety

Day Three: Fire/EMS Safety, Health and Survival Week: Day Three-The New Rules of Engagement

Day Four: Fire/EMS Safety, Health and Survival Week: Day Four -The New Fire Ground

Day Five: Fire/EMS Safety, Health and Survival Week 2011: Day Five: Near-Misses, Maydays and Floor Collapses

Day Six: Fire/EMS Safety, Health and Survival Week 2011, Day Six; From Waldbaum’s to Hackensack-Worcester to Charleston; Legacies for Operational Safety

Day Seven: Fire/EMS Safety, Health and Survival Week 2011, Day Seven; Fire Fighter, Fire Officer and Command Training and Preparedness

Fire/EMS Safety, Health and Survival Week 2011, Days One thru Seven;Training and Preparedness

No comments

Did you remember to participate in the 2011 Fire/EMS Safety, Health and Survival Week?

The International Association of Fire Chiefs (IAFC) and the International Association of Fire Fighters(IAFF) were formative in developing this year’s  2011 Fire/EMS Safety, Health and Survival Week (also known as Safety Week)which commences today, June 19th and ends on June 25th. ( Week of June 19-25, 2011)

The message this year is: Surviving the Fire Ground – Fire Fighter, Fire Officer and Command Preparedness

Safety, Health and Survival Week (Safety Week) is a collaborative program sponsored by the IAFC and the IAFF, coordinated by the IAFC’s Safety, Health and Survival Section and the IAFF’s Division of Occupational Health, Safety and Medicine, in partnership with more than 20 national fire and emergency service organizations.

We’ve got a whole lot of resources, links and daily commentary and articles that were posted on each day of SAfety Week over at CommandSafety.com

If you didn’t have a look and read, take some time to do so. If you didn’t do anything during Safety Week, there’s always next week or the week after… find the time and commit to some training, insights, dialog, discussion…Get Prepared.

Day One: Fire/EMS Safety, Health & Survival Week 2011: Day One- Are You Ready?

Day Two: Fire/EMS Safety, Health and Survival Week: Day Two- Building Knowledge = Fire Fighter Safety

Day Three: Fire/EMS Safety, Health and Survival Week: Day Three-The New Rules of Engagement

Day Four: Fire/EMS Safety, Health and Survival Week: Day Four -The New Fire Ground

Day Five: Fire/EMS Safety, Health and Survival Week 2011: Day Five: Near-Misses, Maydays and Floor Collapses

Day Six: Fire/EMS Safety, Health and Survival Week 2011, Day Six; From Waldbaum’s to Hackensack-Worcester to Charleston; Legacies for Operational Safety

Day Seven: Fire/EMS Safety, Health and Survival Week 2011, Day Seven; Fire Fighter, Fire Officer and Command Training and Preparedness

Eleven Minutes to Mayday; What You Need to Know

2 comments

The Colerain Township (OH) Fire and EMS Department under the leadership of Director and Chief G. Bruce Smith released its final report Investigation Analysis of the Squirrels nest Lane Firefighter Line of Duty Deaths related to the April 4, 2008 Double Line of Duty Death of a Captain and Firefighter in April 2010 coinciding with the two year anniversary of the event.

This investigative analysis and report, although specific to the events and conditions encountered during the conduct of operation at the residential occupancy at 5708 Squirrelsnest Lane has pertinent and relevant insights, recommendations and factors that all Fire Service personnel, regardless of rank should read.

I recently lectured on this incident and the lessons learned at a regional seminar on occupancy profiling and tactical operations, which resulted in significant discussions and dialog pertaining not only to this event but also to the adverse trend and series of  incidents reported nationally in the later part of 2010 and early into 2011 related to comprised or collapsed floor systems and a number of firefighter close calls. There continues to be a number of prevailing philosphies and points of view related to the level of fire ground aggressiveness, tactical patience and level of preparedness demanded on today’s fire ground. I’ve previously posted some insights on these events and these points of view on our Commandsafety.com site and other eMedia sites.

There still appears to be so much that needs to said; lectured, taught, reinforced or just plain introduced to get company and command officers “insightful” into the operational issues affecting modern fire suppression theory, methodologies, operational safety at basement fires or lower elevation fires, compromise and collapse situational awareness, being combat ready during the response and into arrival sequencing and being able to read the building  and fire more effectively and accurately.

I recently had the honor to facilitated an insightful radio program on Taking it to the Streets related to a close-call resulting from a catastrophic and complete floor system collapse in a residential occpancy(HERE) during fire suppression operations and the lessons learned and insights from that event and its recording in the National Firefigher Near Miss Reporting System. Take the time to read about the event ( NMR Report #10-1072) or download the program.

There are tremendous lessons to be shared and learned from the Colerain Township incident, and its one of the required readings that all command and company officers should have on their radar screen (see Commandsafety.com, HERE)

This is one of those distinctive reports that has influential and critical operational, training and preparedness elements embedded throughout the report. Following my review of the report, having previously read the preliminary report findings, it is apparent there continues to be common threads shared by this and other events and incidents where a single of multiple firefighters have lost their lives due to similarities in the apparent and common cause deficiencies and short comings identified.

All company and command officers should read and comprehend the lessons learned. Then, take these new found insights and see what the gaps are at the personal level (yours or those you supervise) as well as the shift, group, station, battalion, division or department as a whole.

If there are gaps, then identify a way to implement timely changes as necessary so there are No History Repeating (HRE) events. Learn from these events….

Thank you to the firefighters, officers and leadership of the Colerain Township (OH) Fire and EMS Department for the comprehensive insights that this report provides and towards the promise that these lessons-learned may one day help a firefighter, crew, company or fire ground in their combat engagement and mission. Do not take any run or response for granted; be combat ready at all levels.

I have provided a comprehensive synopsis of the report for your review. Take the time to read the entire report, make the time to improve where you need to.  

On Friday, April 4, 2008 at 06:13:02 hours, what began as a routine response for Colerain Township Fire and EMS Engine 102 to investigate a fire alarm activation at 5708 Squirrels nest Lane, Colerain Township, Ohio resulted in the deaths of Colerain Township Captain Robin Broxterman and Firefighter Brian Schira.

Upon their arrival at the scene of the two-story wood framed, residential building working fire conditions existed in the basement. The initial attack team consisted of Broxterman, Schira, and one other firefighter. The team advanced a 1¾-inch attack hose line through the interior of the building for fire control.

Even though, they were provided with some of the most technologically advanced protective clothing for structural firefighting and self-contained breathing apparatus, it appeared that Broxterman and Schira were overwhelmed by severe fire conditions in the basement.

During their attempt to evacuate the building, the main-level family room flooring system in which the two were traveling on collapsed into the basement trapping the firefighters. Eleven minutes elapsed from time of arrival to the catastrophic chain of events.

The investigation of this incident provided a number of findings and recommendations that should be considered by Colerain’s fire department, as well as other fire department organizations. The examination encompassed issues that related to building construction, firefighting tactics, command and control, situational awareness, communications, training, firefighting equipment and the individual responsibility of firefighters of the Colerain Township Department of Fire and Emergency Medical Services (Colerain Fire & EMS). In addition, a segment of the examination included a review of the individual and group affects following such an event, and the measures initiated that attempted to ensure individual, family and organizational wellness.

The following factors were believed to have directly contributed to the deaths of Captain Broxterman and Firefighter Schira:

  • A delayed arrival at the incident scene that allowed the fire to progress significantly;
  • A failure to adhere to fundamental firefighting practices; and
  • A failure to abide by fundamental firefighter self-rescue and survival concepts

Although the aforementioned factors were believed to have directly contributed to their deaths, they might have been prevented if:

  • Some personnel had not been complacent or apathetic in their initial approach to this incident;
  • Some personnel were in a proper state of mind that made them more observant of their surroundings and indicators;
  • The initial responding units were provided with all pertinent information in a
  • timely manner relative to the incident;
  • Personnel assigned to Engine 102 possessed a comprehensive knowledge of their first-due response area;
  • A 360-degree size-up of the building accompanied by a risk – benefit analysis
  • was conducted by the company officer prior to initiating interior fire suppression operations;
  • Comprehensive standard operating guidelines specifically related to structural
  • firefighting existed within the department;
  • The communications system users (on-scene firefighters and those monitoring the incident) weren’t all vying for limited radio air time;
  • The communications equipment and accessories utilized were more appropriate for the firefighting environment;
  • Certain tactical-level decisions and actions were based on the specific conditions;
  • Personnel had initiated fundamental measures to engage in if they were to become disoriented or trapped inside a burning building; and
  • Issued personal protective equipment was utilized in the correct manner.

Incident Reported

On Friday, April 4, 2008, at 06:11:23, the Hamilton County Communications Center (HCCC) received notification of an automatic alarm activation (smoke detector and carbon monoxide) at 5708 Squirrels nest Lane (LN).

  • An automatic fire alarm response complement of two engine companies (Engines 102 & 109), one ladder company (Ladder 25), and the Battalion Chief (District 25) were dispatched to investigate at 06:13:02.
  • At 06:13:43, a second notification was received from the female homeowner reporting a fire in the basement of the building.
  • At 06:20:43, a third notification by means of a cellular phone from the female homeowner to HCCC routed through the City of Cincinnati’s Fire and Police Communications Center was received.
  • At 06:22:41, the initial response complement was then upgraded to a building fire, also known as a structure fire response complement to include one additional engine company (Engine 25), one rescue company (Rescue 26), and one basic life support transport unit (Squad 25).

Property and Building Description: The building at 5708 Squirrels nest LN was a single-family residence that set back approximately 450-feet from the street at the end of a private driveway on a heavily wooded lot.

  • The building was two-stories in height, approximately 45-feet wide by 30-feet deep with a finished below-grade (basement) living space and attached two-car garage.
  • For simplicity, the report refers to the living space under the main-level of the building as a basement.
  • From the front (side Alpha), the building was two-stories above grade. The vertical distance between floors was approximately eight-feet. The exterior main entrance was located in the front middle of the building approximately one-foot above grade level.
  • Additional entrances to the first-floor living space were by means of a rear entry door from an upper-level deck area and through the garage area.
  • The interior stairway to the basement was located approximately 15-feet from the front main entry door towards the rear of the building. There were no exposed buildings on the adjacent sides of the fire building.

The building was located approximately 450-feet from the curb and a driveway leading to the front entrance. The nearest fire hydrant was located approximately 500- feet from the front entrance. To provide for uniform identification of locations and operationalforces at the incident scene, the scene was divided geographically into smaller parts, which were designated as sectors. Specific areas of the incident scene were designated as follows:

  • The side of the building that bears the postal address of the location was designated as Side Alpha or front by the Incident Commander;
  • The property sloped downward towards the rear (side Charlie) of the building with an approximate 13-foot elevation difference from side Alpha to Charlie. The
  • Charlie side of the building was three-stories above the rear grade level with the building’s basement floor approximately five-feet above grade level. The exterior entrance to the building’s’ basement area, also known as a walk-out was by means of a stairway that led to a wooden deck on the Charlie side adjacent to the Delta side. A second stairway led to an upper level deck that served the main level of the building.

Initial Fire Attack Operation: Upon arrival at the incident address, Engine 102 (E102), assigned four personnel (one captain, one fire apparatus operator [FAO], and two firefighters) entered and proceeded down the driveway deploying a five-inch supply hose line.

  • With their apparatus positioned in front of the building Captain (Capt.) Broxterman radioed, “Moderate smoke showing. E102 will be Squirrelsnest Command.” at 06:24:01.
  • Verification was made by the E102’s FAO through face-to-face communication with the male homeowner that all occupants were out of the building, which was then relayed to Capt. Broxterman.

District 25 (D25) arrived at the scene at 06:26:35 and assumed Command from Capt. Broxterman. Capt. Broxterman, Firefighter (Ffr.) Schira and E102’s Ffr. #2 advanced a 1¾-inch pre-connected hose line through the front main entrance. The fire was determined to be located in the basement of the building.

  • At 06:27:52, Capt. Broxterman radioed, “E102 making entry into the basement, heavy smoke”.
  • At 06:30:35, E109′s captain radioed, “Command from E109, contact 102,have them pull out of the first floor, redeploy to the back. It’s easy access. Conditions are changing at the front door.”
  • At 06:34:48, Engine 25 (E25), the designated Rapid Assistance Team, had just completed their 360-degree size-up around the building, and encountered E102’s Ffr. #2 in front of the building, whom reported that he had lost contact with his crew.
  • During the time period between 06:29:24 and 06:34:48, the investigation committee believed that one or more catastrophic events occurred including a failure of the main-level flooring system near the Beta – Charlie corner of the building.

 Rescue and Recovery Operations

  • At 06:35:34, the Incident Commander (IC) identified a potential Mayday operation, which indicates a life threatening situation to a firefighter.  
  • RAT25 was deployed at 06:36:48. The actual Mayday operation was initiated by the IC at 06:37:41 followed by a request at 06:37:53 to the HCCC for a second alarm complement of firefighting resources.  
  • At 06:42:01, RAT25 entered the basement from the rear of the building. At 07:00:27, E26’s personnel entered through the front main entrance of the building and into the basement by means of the interior stairway.  
  • Both missing firefighters were located in the basement near the Charlie side wall adjacent to the Beta side following a floor collapse. Capt. Broxterman and Ffr. Schira were obviously deceased as a result of their injuries.

Fire Origin and Cause: Information from the property owners was that the female had smelled an odor in the house. She told her husband, who went to investigate. Neither of them observed any smoke or flames at that time. The husband went to the basement, and located a fire near a cedar wood lined closet used to cultivate orchids in the unfinished utility room. He attempted to extinguish the fire with portable fire extinguishers and pans of water. As the fire alarm activated, the husband had his wife call 9-1-1 to report the fire. The state of Ohio Fire Marshal’s Office Fire and Explosion Investigation Bureau ruled the fire to be accidental in nature. The fire was determined to have originated in the unfinished utility room of the basement level in or near the cedar closet. This area was directly below the family room on the first floor. The probable ignition source for this fire was determined to be at and about a plastic air circulation fan and the associated electrical wiring.

Cause of Deaths

Capt. Broxterman was a 37-year old employee of the Colerain Fire & EMS with approximately 17-years of certified firefighting experience. Capt. Broxterman became trapped in the basement area for a prolonged amount of time following the sudden floor collapse. Capt. Broxterman was found positioned face down over top of Ffr. Schira. The majority of her protective clothing ensemble and equipment were heavily damaged as a result of exposure to heat and direct flame impingement. She was pronounced deceased following her removal from the building. Her body was transported to the Hamilton County Coroner’s Office for autopsy. The Coroner’s report cited the manner of death as “accidental” and the cause of death as “burns and inhalation of smoke and superheated and noxious gases.” Capt. Broxterman sustained burns to 100% of her body surface, which ranged from first to fourth degree in severity as described in the coroner’s autopsy report. Postmortem carboxyhemoglobin (COHb), which is a measure of carbon monoxide exposure, was measured at 22% saturation and soot was observed in portions of her upper and lower respiratory system.

  • Based on the injuries sustained and the damage to Capt. Broxterman’s protective clothing ensemble and equipment, it is likely that she was exposed to a rapid intensification of heat and flames in the building’s basement that overwhelmed her protective ensemble and equipment, exposing her body and respiratory system to intense heat and toxic products of combustion.

Ffr. Schira was a 29-year old employee of Colerain Fire & EMS with approximately 3½-years of certified firefighting experience. He also became trapped in the basement area for a prolonged amount of time following the sudden floor collapse. Ffr. Schira was found positioned on his right side and back, face-up beneath Capt. Broxterman. The majority of his protective clothing ensemble and equipment was heavily damaged as a result of exposure to heat and direct flame impingement. Ffr. Schira was pronounced deceased following his removal from the building. His body was transported to the Hamilton County Coroner’s Office for autopsy. The Coroner’s report cited the manner of death as “accidental” and the cause of death as “burns and inhalation of smoke and superheated and noxious gases”. Ffr. Schira sustained burns to 100% of his body surface, which ranged from first to fourth degree in severity as described in the coroner’s autopsy report. Postmortem COhb was measured at 8% saturation and soot was observed in portions of his upper and lower respiratory system.

  • Based on the injuries sustained and the damage to Ffr. Schira’s protective equipment, it is likely that that he was exposed to a rapid intensification of heat and flames in the building’s basement that overwhelmed his protective ensemble and equipment, exposing his body and respiratory system to intense heat and toxic products of combustion.

Select Findings and Recommendations

Findings, Discussions and Recommendations

FINDING #3.1: The area of fire origin had no finished ceiling, which exposed the floor joists and the underside of the floor decking to direct fire impingement causing rapid deterioration and failure of the flooring system directly underneath the main-level family room.

During this incident, based on communications transcripts (telephone and radio) it’s probable that the fire had advanced from its incipient stage to a free burning stage in approximately 18 to 20-minutes by the time Capt. Broxterman radioed that they were making entry into the basement.

  • As stated in the Incident Overview section, during the time period between 06:29:24 and 06:34:48, it is believed that one or more catastrophic events occurred within the building, which included a failure of the flooring system near the Beta-Charlie corner of the building’s first floor.

It has been widely believed in the firefighting profession that traditional sawn lumber is far superior to some of the more innovative lightweight construction components (e.g., wood I-joist) in use today. With dimensional lumber, two-inch by eight-inch and larger, there is a greater surface to mass ratio to resist the damaging effects of fire and the structural components will maintain their integrity for a longer period of time. While this has traditionally been accurate, this incident clearly shows that this may not always be the case. Heavy charring was evident to structural members in the fire area of origin. Notice the burn damage shows how the wooden floor joists had been burned to and away from the band joist. A band joist is a vertical member that forms the perimeter of a floor system in which the floor joists tie in to. Also known as the rim joist. Early platform framed homes very likely used solid, dimensional lumber and plywood, which provided a reasonable surface to mass ratio. But the later the home was built, the less mass even dimensional lumber has due to the reduction in the actual thickness of solid dimensional lumber provided by the lumber industry through the mid-1900’s. As the years go by, building materials will likely keep getting lighter and lighter and introduce more resins and other chemicals.

Laboratory tests that exposed structural wood components to the American Society for Testing and Materials (ASTM) E119 Assembly Test indicated that a traditional two-inch by ten-inch structural member failed in 12-minutes and six-seconds. ASTM E119 test is the standard test method for evaluating building and construction materials exposed to fire. Unlike the standardized ASTM test fires, it is widely recognized that real building fires are highly variable in their size, rate of growth and intensity. Responding firefighters are unlikely to know when a given fire started, how hot it had been prior to arrival, how long it had been at any given temperature, the design capacity and actual loads on the floors over the fire or the amount of actual damage that the fire may have done to the joists. All of these factors make it impossible to predict the remaining capacity of a floor by even the most knowledgeable, professional fire experts.

RECOMMENDATION #3.1a: Fire departments should ensure that firefighters and incident commanders are aware that unprotected floor and ceiling joist systems, no matter the type, may fail at a faster rate when exposed to direct fire impingement.

Unfinished basement ceilings and other areas that have exposed joists or trusses jeopardize flooring and roof systems unnecessarily during a fire, causing premature failure. Often, a weakened floor and ceiling joist system can be difficult to detect from above as the floor surface above may still appear intact. Firefighters operating on floors above fire-damaged joist systems may fall through a weakened area and become trapped in a fire below. IC’s and firefighters must be aware that these systems can fail rapidly and without warning, and plan interior operations accordingly.

Firefighters must also be aware that while floor sag may be a widely accepted warning of an impending structural failure, floor sag is not always present or visible prior to a catastrophic collapse in a fire, regardless of the joist type, due to floor coverings, the fire’s intensity, the combination of joist spans and loads present, the location of serious structural fire damage or simply because it is too dark and smoky to see a sag in the floor. This is true for all types of structural joists, including materials such as sawn lumber, wood I-joists, and open web wood trusses and noncombustible members such as lightweight steel joists. The floor covering in this area was carpeting that transitioned to ceramic tile. When unprotected, any traditional or lightweight residential floor or ceiling assembly material, either combustible or noncombustible, may fail within several minutes of the fire’s ignition. It makes sense, therefore, that when there is a serious fire beneath a floor, there is no predictable safe amount of time that anyone can remain on that floor. Any floor system protected or not, can fail unpredictably when exposed to a substantial fire beneath.

FINDING # 4.2: E102′s officer failed to properly analyze the scene by not performing a 360-degree scene size-up to determine an overall strategy, and implement safe and effective firefighting tactics.

After the apparatus was positioned in front of the building, E102’s FAO was ordered by Capt. Broxterman to, “Ask the homeowner where the fire [location] was”, which was indicated to be in the basement by the male homeowner. As this was taking place, Capt. Broxterman continued donning her protective clothing ensemble (coat, helmet and self-contained breathing apparatus). Although E102′s officer provided a brief radio report of conditions observed upon arrival, she did not properly evaluate the scene so as to develop a basic strategy for implementation of safe and effective firefighting tactics. Had the officer visually evaluated the Charlie side of the building, the advanced fire conditions may have been noted, and that the lower level fire area was accessible by means of an exterior entry door for a more direct fire attack from the interior unburned side.

This means that firefighters enter a building and position the attack hose line between the fire and the uninvolved portions of the building. This direction of fire attack is preferred because it is likely to contain the fire, protect occupants, and push heat and gases out of the building if ventilation has been performed. On the other hand, danger increases significantly when attacking from the unburned side and is not always practical based on fire location, intensity, and building construction.

It cannot be conclusively known as to why Capt. Broxterman and Ffr. Schira proceeded into the area of the building that eventually collapsed resulting in their deaths. The investigation committee has concluded that the most probable explanation is that E102′s three-person interior team was successful in advancing their uncharged attack hose line into the basement recreation room area; reaching a point approximately 10 to15-feet from the bottom of the basement stairway as shown in the Incident Overview chapter. Once the team reached this area, it was realized they did not have sufficient hose line to continue advancing towards the seat of the fire. The team’s third member (Ffr. #2) reversed his travel and made his way back to the exterior of the building to advance additional hose line. As the team of two waited for additional hose line to be stretched and the hose line to be charged by the pump operator, the interior conditions rapidly deteriorated to a stage that it became untenable for them to hold their position.

The team evacuated back-up the stairway without following the hose line, which by all indications was tight up against the stairway wall and tightly wrapped around the stairway door entry. Once at the top of the stairway, one of the two deceased, if not both were likely in some form of distress; became disoriented and proceeded into the family room in a direction opposite the route of travel from which they entered the building. As the two moved across the family room floor, the flooring system collapsed into the utility room area of the basement. When the third team member re-entered the building, he was unable to locate the other two members.

The inability of Ffr. #2 to locate his team and the loss of radio communications contact with the interior team prompted the IC to declare a Mayday and activation of the RATs. This incident resulted in tragedy primarily due to the concealment of several burned-through floor joists under the carpet covered flooring system, which was nearly impossible to recognize due to heavy smoke conditions inside the burning building.

The following factors are believed to have directly contributed to the deaths that occurred in this incident:

  • The delayed arrival at the incident scene allowed the fire to progress significantly and the hazardous conditions to exponentially increase;
  • The failure to adhere to fundamental firefighting practices (e.g., entry into an enclosed building with obvious working fire conditions without a charged attack hose line)
  • The failure to abide by the fundamental concepts of fire fighter self-rescue and survival (e.g., following of the hose line in the direction of travel back to the building’s entrance or exit).

Although the aforementioned factors are believed to have directly contributed to the deaths reported here, they might have been prevented if:

  • Some personnel had not been complacent or apathetic in their initial approach to this incident which eventually led to being overwhelmed in their response to their initial findings;
  • Some personnel were in a proper state of mind that made them more observant of their surroundings and indicators, and the potential threats and risks that presented themselves;
  • The initial responding units were provided with all pertinent information in a
  • timely manner relative to the incident, especially critical was the information given to the emergency communications center from the homeowners reporting an actual fire
  • Personnel assigned to E102 possessed a comprehensive knowledge of their firstdue response area specifically related to road and street locations, and any particular characteristics related to those areas.
  • A 360-degree size-up of the building accompanied by a risk – benefit analysis was conducted by the company officer prior to initiating interior fire suppression operations; the risk of an action must be weighed against the probable benefit that may be reasonably and realistically expected.
  • Comprehensive standard operating guidelines specifically related to structural firefighting existed within the department;
  • The communications system users (on-scene firefighters and those monitoring the incident) weren’t all vying for limited radio air time. This competition led to missed and distorted messages and less than efficient use of resources, which exacerbated the problems of already taxed communications.
  • The communications equipment and accessories utilized were more appropriate for the firefighting environment;
  • Certain tactical-level decisions and actions were based on the specific conditions as encountered with an emphasis placed on fire ground tactical priorities (i.e., life safety, incident stabilization and property conservation);
  • Personnel had initiated fundamental measures to engage in if they were to become disoriented or trapped inside a burning building; and
  • Issued personal protective equipment was utilized in the correct manner.

In Memory

The Colerain Township (OH) Department of Fire and Emergency Medical Services’s report examined the events of April 4th, 2008 with the benefit of hindsight, while seeking to be independent, impartial, and thorough. From the beginning, Colerain Fire & EMS has been committed to share our findings with others in the hope that it may prevent another such event.

The deaths of Captain Robin M. Broxterman and Firefighter Brian Schira had a profound loss not only to their parents, family and this organization, but also to the larger fire service community. In order to prevent these tragic losses in the future, we must first understand how and why our sister and brother firefighters died. We must learn from their incident and take that knowledge forward. If it was possible, what would these firefighters tell us today that might prevent a similar death of a firefighter in the future? What would they want us as firefighters, company officers and chief officers to know about the circumstances that lead to their deaths and the things we (and they) might have done to alter the most tragic of outcomes?

From the information that was made available for review, it was evident that these two individuals were well-loved in life, and greatly missed in death. Every line of duty death of a firefighter in the United States is significant. This investigative analysis document is dedicated to Captain Broxterman and Firefighter Schira, their families, friends and the community whose lives were forever changed. In working to improve the health and safety of all United States firefighters, we have much to learn from the supreme sacrifice of these two individuals, who they were in life and in death. We honor their memories.

 

References

  • Colerain Township Department of Fire and Emergency Medical Services, Web Site HERE
  • Investigation Analysis of the Squirrels nest Lane Firefighter Line of Duty Deaths April, 2010 Full Report HERE
  • NIOSH Fire Fighter Fatality Investigation Report F2008-09| CDC/NIOSH July, 2009, Report HERE
  • WLTW.com news report Summary HERE

 

 

Six Detroit Firefighters Injured at Taxpayer Fire from Wall Collapse

No comments

Detroit News

Six Detroit firefighters were injured during operations at a two alarm fire at a commercial taxpayer fire on the city’s east side. Initial reports indicate a roof collapse and subsequent compromise and further collapse occurred on the alpha side of operations with additional reports of an explosion preceding the collapse. Additional information provided by the Detroit Fire Department indicated the building structure had sustained some degree of damage from fire operations a few hours earlier and that during the suppression operations  at 07:00 hours, while companies were operating, a facade collapse of the perimeter brick wall occured.
The brick facade collapse trapped a number of firefighters under the debris pile requiring extrication and removal. Published report indicate that the following Detroit Firefighters were injured as a result of the collapsing facade wall;

• Lt. Gerald Rutkowski, 46; 23 years with department

• Shane Raxter, 32; 9 years with department.

• Brian Baulch, 31; 9 years with department.

• Jeron Whitehorn 30; 8 years with department.

• Eric Jurmo, 31; 11 years with department.

• Brendan Milewski, 31; 11 years with department

It appears the two story brick structure located at the corner block had commercial occupancies on the number one floor, with the second floor boarded up, evidenced by the coverings over the windows.
The facade collapse of the alpha side in the predominate location of perimeter windows is typically the least stable of areas in buildings of type III ordinary construction. Lacking any significant mass and increased wythe, non-bearing walls have less mass and require stability of the adjacent floor systems and load bearing lintels and beams to maintain structural stability and integrity. Gravity affects unstable brick veneer and in-fill walls greatly as does other imposed loads, hose and master streams impacts.  We’ll post more building construction insights and safety aides to increase your operational awareness on these type of building structures.
 
Here are the links to the lastest information forthcoming;
  • Detroit News, HERE
  • Firegeezer Coverage, HERE
  • Detroit Fox News, HERE
  • Latest news on FireFighter Nation, HERE
  • Statter911.com, Here
  • The Detroit Free Press, Here
  • Photo Gallery, Here
Here’s a link to a PPT program that’s available on the National Firefighter Near Miss Reporting System site on Operational Safety Considerations at Buildings of Ordinary and Heavy Timber Construction; Type III and IV Structures. An accompanying narrative is available on the same NMRS Resource page that I posted in 2009.
 
 
Some recent NIOSH Reports related to Commercial Building Occupancy Fires and their lessons;
  • Career Lieutenant Dies Following Floor Collapse into Basement Fire and a Career Fire Fighter Dies Attempting to Rescue the Career Lieutenant – New York,  HERE
  • Floor Collapse at Commercial Structure Fire Claims the Lives of One Career Lieutenant and One Career Fire Fighter – New York, Here
  • Hardware Store Explosion Claims the Lives of Three Career Fire Fighters-New York, Here
  • Volunteer Fire Chief Killed when Buried by Brick Parapet Wall Collapse – Texas, Here
  • Commercial Structure Fire Claims the Life of One Firefighter-California, Here
  • Partial roof collapse in commercial structure fire claims the lives of two career fire fighters – Tennessee, Here
Additionally here are some images pulled from various online sources depicting the building, it’s construction, layout and configuration.

Detroit New Photo


3*4*3 Reports

No comments

I recently posted an article on CommandSafety.com that addressed a series of Major Influencing Fire Service Reports, Issues and Focus areas that should be on your radar screen. This was also the theme at the premiere of Taking it to the Streets on Fire Fighter Netcast.com . As an emerging, practicing or upward mobile fire officer, commander or leader; those are but a few key ares that you must be  knowledgeable in, have insights and proficiency based technical skills to function with a level of competencies demanded of, in today’s  fire service.

After a recent training program, we discussed in a smaller group setting common, contributing and apparent causes related to three prominent fire incidents and reports that were shared both within the lecture program and also within the CS post. Based upon that dialog, the dynamic and passionate discussion and the frank, straight forward opinions I’m suggesting you take the time; three hours to read three reports and focus on the lesson learned, the gaps that were identified and the recommendations AND actions that were implemented to limit, if not eliminate the likely hood that a similar event could happen in that organization.

The continuing challenge is not allowing the circumstances and situations that were present at those events, cause you and your organization to have a History Repeating Event (HRE).

Set aside three hours for three reports; invest the time appropriately and focus your undivided attention. Think about those firefighters who answered that call, in the same manner and fashion as all of us do, when we board the apparatus and the company rolls out of quarters on the way to the alarm. The only difference…..they didn’t come home- you did. Learn, understand, comprehend, relate and apply.

Then take the time to share your insights with those within your inner circle and start recognizing that there’s likely something that you can go in your house or station, or organization that honors the sacrifices made by those LODD events your read about, so those lessons can be moved forward to make the job, a little bit safer.

Three for Three (343)

Prince William County (VA) Fire Rescue Kyle Wilson LODD Report

  • The Prince William County (VA) Department of Fire and Rescue published a comprehensive line of duty death report for Technician I Kyle R. Wilson on Saturday, January 26, 2008. Technician I Wilson was the first line of duty death in the Department’s 41-year history. The Department is sharing the LODD Investigative Report to honor Kyle, and in an effort to reduce and prevent firefighter line of duty deaths at the local, region, state, and national levels.
  • Technician Kyle Robert Wilson was 24-years old and was born in Olney, Maryland. He grew up in Prince William County and graduated from Hylton High School and George Mason University. He was an avid baseball and softball player. Technician Wilson joined the Prince William County Department of Fire and Rescue on January 23, 2006. Technician Kyle Wilson died in the line of duty on April 16, 2007 while performing search and rescue operations at a house fire on Marsh Overlook Drive, located in the Woodbridge area of Prince William County. On that day, Technician Wilson was part of the firefighter staffing on Tower 512 which responded to the house fire that was dispatched at 0603 hours. The Prince William County area was under a high wind advisory as a nor’eastern storm moved through the area. Sustained winds of 25 mph with gusts up to 48 mph were prevalent in the area at the time of the fire dispatch to Marsh Overlook Drive.
  • Initial arriving units reported heavy fire on the exterior of two sides of the single family house and crews suspected that the occupants were still inside the house sleeping because of the early morning hour. A search of the upstairs bedroom commenced for the possible victims. A rapid and catastrophic change of fire and smoke conditions occurred in the interior of the house within minutes of Tower 512’s crew entering the structure.
  • Technician Wilson became trapped and was unable to locate an immediate exit out of the hostile environment. Mayday radio transmissions were made by crews and by Technician Kyle Wilson of the life-threatening situation. Valiant and repeated rescue attempts to locate and remove Technician Wilson were made by the firefighting crews during extreme fire, heat and smoke conditions. Firefighters were forced from the structure as the house began to collapse on them and intense fire, heat and smoke conditions developed. Technician Wilson succumbed to the fire and the cause of death was reported by the medical examiner to be thermal and inhalation injuries.
  • The Department of Fire and Rescue immediately formed a multi-dimensional investigation team following the incident. The investigation team was comprised of five Department of Fire and Rescue uniform personnel and two external members from area fire departments. For eight months, the team thoroughly examined the events that occurred at the Marsh Overlook fire incident and identify the factors involved with the line of duty death of Technician I Kyle Wilson. The resulting report represents thousands of hours of effort to analyze fire and rescue operations and is a factual representation of the events that occurred. The report also provides a frame work for organizational level improvements.
  • The major factors in the line of duty death of Technician I Wilson were determined to be:
    • The initial arriving fire suppression force size.
    • The size up of fire development and spread.
    • The impact of high winds on fire development and spread.
    • The large structure size and lightweight construction and materials.
    • The rapid intervention and firefighter rescue efforts.
    • The incident control and management.
    • The Marsh Overlook fire incident was an immense fire fueled by extremely flammable building material products and a vicious wind. It was an environment where information gathering and decision making had to be performed in the time measurement of seconds. During the chain of events that occurred and under severe circumstances, fire and rescue personnel performed at exceptional levels.
  • During the repeated attempts to reach and rescue Technician I Wilson, personnel displayed heroic efforts and jeopardized their own safety. The Department will never forget the sacrifice that Technician Wilson made in an attempt to ensure others were safe. By sharing the knowledge gained from this very tragic and painful incident, the Department will ensure his sacrifice was not in vain and hope that other fire and rescue departments can avoid another similar occurrence.
  • Resources and Report

Loudoun County (VA) Fire Rescue  Significant Near Miss Event Report

  • On May 25, 2008, fire and rescue personnel from Loudoun County responded to a structure fire at 43238 Meadowood Court in Leesburg, Virginia. During the course of the incident, seven responders were injured. Of those injured, four firefighters received significant burn injuries, two firefighters sustained orthopedic injuries, and one EMS provider was treated for minor respiratory distress. To date, five of the injured personnel have returned to duty. Two firefighters continue to recover from their injuries, including one who was severely burned.
  • Given the severity of the injuries and magnitude of the event, an independent Investigative Team was assembled to review the incident. The Team was comprised of four Loudoun County personnel, three external members from area fire departments, and two resource/support personnel. The Team was tasked with reviewing “the events leading up to the incident, the incident operation(s), the firefighter MAYDAY(s), and incident mitigation.”
  • For three months, the Team thoroughly examined the events surrounding the Meadowood Court fire incident and identified the factors associated with the injury of personnel.
  • The Report contains the results of the Investigative Team’s comprehensive review and analysis.
  • Fact Sheet, HERE
  • SIGNIFICANT INJURY INVESTIGATIVE REPORT 43238 MEADOWOOD COURT MAY 25, 2008 Report HERE

Colerain Township (OH) Fire and EMS Department Final Report Investigation Analysis of the Squirrels Nest Lane Firefighter Line of Duty Deaths

  • The Colerain Township (OH) Fire and EMS Department under the leadership of Director and Chief G. Bruce Smith recently released its final report Investigation Analysis of the Squirrels nest Lane Firefighter Line of Duty Deaths related to the April 4, 2008 Double Line of Duty Death of a Captain and Firefighter.  This investigative analysis and report, although specific to the events and conditions encountered during the conduct of operation at the residential occupancy at 5708 Squirrels nest Lane has pertinent and relevant insights, recommendations and factors that all Fire Service personnel, regardless of rank should read.
  • Incident Overview, HERE
  • NIOSH Report, HERE
  • Investigative Report, HERE
Related Posts with Thumbnails