Near-Miss, with RIT Deployment at Structural Collapse: Canada

No comments

A rapid and fast moving early morning fire in downtown Trenton, Ontario Canada resulted in the subsequent collapse of a three story mixed use commerical and apartment occupancy structure. Published media reports indicated the building was over 130 years of age and was in operation as an adult entertainment establishment on the lower level with multiple occupancy use apartments on the upper floors. The fire displaced 12 residents. The commercial portion of  the building on the number one floor was not operating at the time of the alarm.

For a complete overview of the general fire, refer to the links below for the media links.

Two firefighters were nearly trapped while engaged in primary search and rescue operations as the fire conditions deteriorated and compromise and collapse  conditions began to collapse the wood frame structure.

Pre-incident images clearly depict the typical building profile of a heritage type structure of the late 1880′s vintage with it’s sloping roof profile and window treatments that are evident on both the bravo and delta divisions (many with window mounted air conditioning units that constitute a collapse risk to operating companies on the ground perimeter) . As with many buildings in urban areas, the exterior envelope has been renovated in a manner that added an exterior metal clad panel system that is typically mechanically fastened directly to the facade or to a sub-assembly fastening system. This in effect covers the buildings originating facade, building materials and structural and cosmetic conditions.

Common to original building construction and layouts, the alpha division shows the manner in which the first floor wall has been modified with no indication of window locations and conditions in the upper floors. Common to this renovation technique is the placement of the metal facade directly over existing window openings and framing systems, resulting in either boarded and elimination of the window or the fames and glass still present within the interior room compartments compounding search and rescue assignments.

Sherwood Forest Inn, Image from Google Street View

 The metal exterior cladding masks the ability for arriving companies to identify if the structure is wood frame Type V, ordinary Type III or Brace Frame construction.  The profile and charactoristics of this building profile suggests a buidling of Type III Ordinary construction ( Brick and jost) with load bearing masony construction. This is not the case in this structure as fireground photos further depicted. The various fireground photos suggest that this was a wood frame structure with wood exterior sheathing with some brick masonry features applied to the alpha division. The building envelope is encased in a sheet metal panel cladding system attached the perimeter facade.

 

Delta Division, Google Street View Image

  

Image above shows the degree of interior fire involvement and smoke density. The sheet metal cladding that was applied to the surface facade masks the ability to monitor wall degradation and compromise, retains heat within the building envelope and has independent collapse considerations based upon the manner it is atached to the outer facade further compounding the structural integrity of the buildings wall envelope. Photo by Step Crosier.

In incidents taht have building profiles such as this, conservative risk management, establishment of primary and secondary collapse perimeters along the various divisions is imperative for firefighter safety and apparatus operabilty.

Collapse and failure of the primary structural support systems affecting both interior and exterior structural and infill systems. Photo by Marc Venema

The image above shows the extent of collapse. Look at the various construction features consisting of the original wood plank sheathing, brick facade work, wood framing system and the retrofitted metal paneling facade.  

  • How would you Read the Building based upon the pre incident photos shown at the being of this post?
  • Would you assume the building was a type III or IV structure or a wood frame or brace frame structure?
  • Does each building system have a different bearing on fireground operations, strategies, tactics and operational integrity and company and personnal safety?
  • How much operatoinal time do you have for a primary search and rescue assignment or for deployment and effective location of a fire seat and application of hose streams before you developing compromising conditions with the interior compartments?

 

Look at the brick veneer added to the wood sheathing covered by the metal panels in this image. Photo by Steph Crosier

 

 

 

   

 

The Ides of March: Learning and Remembrance

No comments
 
Operational Safety

Here are five (5) NIOSH Firefighter LODD Event report summaries for incidents that occurred in the March 4th through the 8th time frame in the years 1998, 2001, 2002, 2008.

Take the time to look over the event summaries, discuss and comment on the factors that lead to the events and the recommendations formulated from the subsequent investigations.

Take the opportunity to identify the common themes and apparent causes that were identified and discuss with your company, team or station, relevant considerations that may have a direct or indirect relationship to your organization, past incident calls or district risk profile.

What are your capabilities?

What are your gaps?

How can you prevent a similar situation from occurring?

Promote questions and dialog related to operational issues such as these;

  • Coordinated multi-company operations; how “coordinated” is your incident scene?
  • Do rapidly changing incident conditions get identified promptly and communicated to Command in rapid succession for actions?
  • How effective is the base line knowledge and skill set of company and command officers in “reading the building”?
  • What is the adequacy of your training for conducting operations above the fire floor?
  • When was the last time you “tested” the effectiveness of your RIT/FAST Team? Can they truly perform under the most demanding of incident conditions?
  • When was the last time you trained or drilled on Fire Behavior or on Building Construction?
  • Are you training on calling the mayday and personal survival techniques?
  • Have you implemented and trained on procedures for rapid and efficient transition in operational modes on the fireground?
  • Do you implement a 360 when applicable and delegate when needed?
  • What parameters are you operating under when assuming risk on the fireground?
  • What drives your incident operations: Are they Tactically Drive or Risk Managed?

Down load the complete NIOSH Reports and expand on the lessons learners and their applicably to your organization and capabilities.

Manlius, New York

Floor Collapse and Fire Conditions:
On March 7, 2002, a 28-year-old male volunteer fire fighter and a 41-year-old male career fire fighter died after becoming trapped in the basement. One firefighter manned the nozzle while second firefighter provided backup on the handline as they entered the house. After entering the structure, the floor collapsed, trapping both victims in the basement.

A career fire fighter captain joining the fire fighters near the time of the collapse was injured trying to rescue one of the fire fighters. Crew members responded immediately and attempted to rescue the victims; however, the heat and flames overcame both victims and eliminated any rescue efforts from the garage entrance.

NIOSH investigators concluded that, to minimize the risk of similar occurrences, fire departments should;

  • Ensure that the Incident Commander is clearly identified as the only individual responsible for the overall coordination and direction of all activities at an incident
  • Ensure that the Incident Commander conveys strategic decisions to all suppression crews on the fireground and continually reevaluates the fire condition
  • Ensure that Incident Command conducts an initial size-up of the incident before initiating fire fighting efforts and continually evaluates the risk versus gain during operations at an incident
  • Ensure that fire fighters from the ventilation crew and the attack crew coordinate their efforts
  • Ensure that fire fighters report conditions and hazards encountered to their team leader or Incident Commander
  • Ensure fire fighters are trained to recognize the danger of operating above a fire

NIOSH REPORT: http://www.cdc.gov/niosh/fire/reports/face200206.html

Wall Collapse and Fire Conditions
On March 7, 2008, two male career fire fighters, aged 40 and 19 were killed when they were trapped by rapidly deteriorating fire conditions inside a millwork facility in North Carolina. The captain of the hose line crew was also injured, receiving serious burn injuries.

The victims were members of a crew of four fire fighters operating a hose line protecting a firewall in an attempt to contain the fire to the burning office area and keep it from spreading into the production and warehouse areas. The captain attempted to radio for assistance as the conditions deteriorated but fire fighters on the outside did not initially hear his Mayday. Once it was realized that the crew was in trouble, multiple rescue attempts were made into the burning warehouse in an effort to reach the trapped crew as conditions deteriorated further.

Three members of a rapid intervention team (RIT) were hurt rescuing the injured captain. One firefighter was located and removed during the fifth rescue attempt. The second firefighter could not be reached until the fire was brought under control.

The fourth crew member had safely exited the burning warehouse prior to the deteriorating conditions that trapped his fellow crew members. Key contributing factors identified in this investigation include radio communication problems (unintelligible transmissions in and out of the fire structure that may have led to misunderstanding of operational fireground communications), inadequate size up and incomplete pre-plan information, a deep-seated fire burning within the floor of the office area that was able to spread into the production and warehouse facility, the procedures used in which operational modes were repeatedly changed from offensive to defensive, lack of crew integrity at a critical moment in the event, and weather which restricted fireground visibility.

NIOSH investigators concluded that, to minimize the risk of similar occurrences, fire departments should:

  • Ensure that detailed pre-incident plan information is collected and available when needed, especially in high risk structures
  • Limit interior offensive operations in well-involved structures that are not equipped with sprinkler systems and where there are no known civilians in need of rescue
  • Develop, implement, and enforce clear procedures for operational modes. Changes in modes must be coordinated between the Incident Command, the command staff and fire fighters
  • Ensure that Rapid Intervention Crews (RIC) / Rapid Intervention Teams (RIT) have at least one charged hose line in place before entering hazardous environments for rescue operations
  • Ensure that the incident commander establishes the incident command post in an area that provides a good visual view of the fire building and enhances overall fireground communication
  • Ensure that crew integrity is maintained during fire suppression operations
  • Encourage local building code authorities to adopt code requirements for automatic protection (sprinkler) systems in buildings with heavy fire loads.

NIOSH REPORT http://www.cdc.gov/niosh/fire/reports/face200807.html

Floor Collapses in Residential Fire - North Carolina

 

Floor Collapse
On March 4, 2002, a 22-year-old male career fire fighter was injured and subsequently died and a 25-year-old male Captain was injured when the floor collapsed while they were fighting a residential fire.

The Captain was transported by ambulance to an area hospital where he was admitted overnight for first- and second-degree burns. The victim was conscious and was transported by medical helicopter to a State medical center where he died 2 days later.

NIOSH investigators concluded that, to minimize the risk of similar occurrences, fire departments should;

  • Ensure that each Incident Commander conducts a size-up of the incident before initiating fire-fighting efforts, after command is transferred, and continually evaluates the risk versus gain during operations at an incident
  • Ensure fire fighters are trained to recognize the dangers of searching above a fire
  • Ensure that an Incident Safety Officer, independent from the Incident Commander, is appointed
  • Ensure that ventilation is closely coordinated with fire attack
  • Ensure that a Rapid Intervention Team is established and in position immediately upon arrival
  • Ensure that adequate numbers of staff are available to operate safely and effectively

NIOSH REPORT http://www.cdc.gov/niosh/fire/reports/face200211.html

 

Fall Through Floor Fighting a Structure Fire at a Local Residence - Ohio

 

Floor Collapse
On March 8, 2001, a 38-year-old male career fire fighter fell through the floor while fighting a structure fire, and died 12 days later from his injuries. At 1231 hours, Central Dispatch notified the career department of a structure fire with reports of the occupants still inside. The Assistant Chief arrived on the scene along with Engine 70 and assumed Incident Command (IC).

The IC immediately called for the second alarm, began conducting the initial size-up of the structure, and confirmed heavy fire in the left front section. At that time, the neighbors approached the IC and informed him that the occupants were trapped inside. The IC ordered the fire fighters on scene to commence search and rescue efforts, and then verified the stability of the structure through radio and face-to-face communications.

Engine 68 arrived on the scene at approximately 1250 hours with an Assistant Chief and the victim. The Assistant Chief provided tactical command of the fire ground, and along with the victim, conducted search and rescue operations. Other crews conducted searches with a thermal imaging camera of the first floor and basement level of the residence with no sign of any occupants. During these searches the stability of the structure was diminishing due to the intense fire that was now venting through the roof.

Fire fighter #3 and the victim were at the front entrance conducting a defensive attack as the third emergency evacuation signal was sounded. The neighbors were still insisting to the IC and fire fighters that the occupants were trapped inside, and one of the occupants was handicapped. The victim and one other fire fighter conducted another search of the structure.

The heat and flames were now extending from the basement level to the first floor when the fire fighter’s low air alarm sounded. The victim and the fire fighter were backing out of the structure when the floor beneath the victim gave way, causing him to fall through the floor and become trapped in the basement.

Attempts were made from the first floor to rescue the victim by utilizing a handline and an attic ladder, but they were unsuccessful due to the intense heat and flames. Two Rapid Intervention Teams (RIT #1 & RIT #2) were deployed simultaneously from separate entrances into the basement to perform a search and rescue operation for the downed fire fighter. The RITs were able to locate and remove the victim on their initial entry. He sustained third degree burns to over half of his body and died 12 days later.

NIOSH investigators concluded that to minimize the risk of similar occurrences, fire departments should;

  • Ensure that Incident Command continually evaluates the risk versus gain during operations at an incident
  • Ensure that a separate Incident Safety Officer independent from the Incident Commander is appointed
  • Ensure that fire fighters are trained in the tactics of defensive search
  • Ensure that fire fighters performing fire fighting operations under or above trusses are evacuated as soon as it is determined that the trusses are exposed to fire
  • Ensure consistent use of Personal Alert Safety System (PASS) devices at all incidents and consider providing fire fighters with a PASS integrated into their Self-Contained Breathing Apparatus which provides for automatic operation
  • Ensure that personnel equipped with a radio, position the radio to receive and respond to radio transmissions

NIOSH REPORT: http://www.cdc.gov/niosh/fire/reports/face200116.html

 

Roof Collapse and Fire Conditions
On March 8, 1998, one male fire fighter, the Captain on Engine 57, died while trying to exit a commercial structure after his egress was cut off by the wooden trussed roof that collapsed. Task Force 66 was the first on scene and reported light smoke showing from a one-story commercial building. A ventilation team from Truck 66 proceeded to the roof of the building and commenced roof ventilation. Forcible entry into the building required about 7 ½ to 9 ½ minutes from arrival on scene to force open the two metal security doors in the front. While fire companies waited for the security doors to be opened, fire conditions changed dramatically on the roof.

Fire was coming from the ventilation holes opened by the ventilation crew. As soon as the security doors were opened, three engine crews (Engine 66, Engine 57, and Engine 46) advanced hand lines through the front door in an attempt to determine the origin of the fire. Approximately 15 feet inside the front door, the fire fighters encountered heavy smoke with near zero visibility conditions. The engine crews advanced their hose lines approximately 30 to 40 feet inside the building.

As conditions continued to deteriorate inside the building, the members from the four engine companies involved in the fire attack began to withdraw. During this time the victim became separated from his crew and remained in the building. The victim was subsequently located by the Rapid Intervention Team and cardiopulmonary resuscitation was performed immediately and en-route to the hospital, where the victim was pronounced dead.

NIOSH investigators conclude that, to prevent similar occurrences, fire departments should:

  • Ensure that incident command conducts an initial size up of the incident before initiating fire fighting efforts, and continually evaluate the risk versus gain during operation at an incident
  • Ensure that incident command always maintains close accountability for all personnel at the fire scene
  • Ensure communications are established between the interior and exterior attack crews, e.g., the ventilation crew and the interior fire attack crew should communicate conditions among themselves and back to incident command
  • Ensure that Rapid Intervention Teams are in place before conditions become unsafe
  • Ensure that some type of tone or alert that is recognized by all fire fighters be transmitted immediately when conditions become unsafe for fire fighters
  • Ensure sufficient personnel are available and properly functioning communications equipment are available to adequately support the volume of radio traffic at multiple-responder fire scenes
  • Consider placing a bright, narrow-beamed light at the entry portal to a structure to assist lost or disoriented fire fighters in emergency egress.

NIOSH REPORT: http://www.cdc.gov/niosh/fire/reports/face9807.html

 

Taking it to the Streets on Firefighternetcast.com

Taking it to the StreetsTM

Download the program from March 16th, 2011  Program

Featured a two part program on Near Miss Firefighter Reporting with Lt. Steve Mormino, FDNY (ret) and Capt. CJ Haberkorn, Denver (CO) Fire Department and  special guest, Captain Michael Long, who provided a personal Near-Miss Event account you won’t want to miss.

Check out the latest downloads of recent programs in the archives by visiting Taking it to the Street’s webpage on Firefighternetcast.com or for program insights at CommandSafety.com.

  • Download the program from March 16th, 2011  Program on Firefighternetcast.com HERE
  • Taking it to the Streets Radio Programs, HERE and HERE

Taking it to the StreetsTM is a monthly radio show featured on BlogTalk Radio and is hosted by Christopher Naum and is a Buildingsonfire.com Series and FireFighternetcast.com Production, © 2010-2012 All Rights Reserved

National Firefighter Near-Miss Reporting System; Untapped Resource

No comments

Have you heard about the National Firefighter Near-Miss Reporting System (NMRS)? Have you used the NMRS Reports, or submitted a near miss event? Did you know there is a wealth of resources available on the NMRS web site or that there is a Report of the week that is published weekly?

If not, this is a great opportunity to learn about this national fire service program.    

 The National Fire Fighter Near-Miss Reporting System is a voluntary, confidential, non-punitive and secure reporting system with the goal of improving fire fighter safety.    

Submitted reports will be reviewed by fire service professionals. Identifying descriptions are removed to protect your identity. The report is then posted on this web site for other fire fighters to use as a learning tool.    

The reporting system is funded by the U.S. Department of Homeland Security’s Assistance to Firefighters Grant Program. The program was originally funded by DHS and Fireman’s Fund Insurance Company.    

There are three main goals:
1.  To give firefighters the opportunity to learn from each other through real-life experiences;
2.  To help formulate strategies to reduce the frequency of firefighter injuries and fatalities; and
3.  To enhance the safety culture of the fire and emergency service.    

Fire fighters can use submitted reports as educational tools. Analyzed data will be used to identify trends which can assist in formulating strategies to reduce fire fighter injuries and fatalities. Depending on the urgency, information will be presented to the fire service community via program reports, press releases and e-mail alerts.    

Why should I submit a near-miss report? A near miss experienced by a firefighter can improve the knowledge, skills and abilities of everyone who is made aware of it.  Reporting your near-miss event to www.firefighternearmiss.com will help prevent an injury or fatality of a firefighter.  Near-miss reporting has worked effectively in other industries, especially aviation, since team members have more knowledge.  Industries using near-miss reporting systems have lower injury rates and fewer worker fatalities.   

YouTube Preview Image 
 
 As a Company or Command Officer you have an obligation to capture your department’s near-miss events and contribute to the National Firefighter Near-Miss Reporting System data base so the fire service can learn from each event with the objective that they are not repeated or escalate into something more severe or significant in terms of injuries or line of duty death events.
 
Take the time to browse through the NMRS web site and familiarize yourself with the content, resources and information available to you.
 
Realize that the resource center and the near-miss reports are all formulative and can very easily support training drill development, just in time training, table-top discussions, scenario based exercises and review discussions with company, staff or command officers and all station or company personnel.NMRS Resource Section, HERE 
 
 
Links:    
 
 
 
 
 
 

 

   Got a Near-Miss Report to Submit?

Click on the button for a direct link to the NFNMRS here

   

 

Frequent Questions:    

   

Taking it to the Streets, Blogtalk radio on Firefighternetcast.com (link here)

Mark your calendars for Wednesday March 16th at 9:00pm ET for a new edition of Taking it to the Streets, where we’ll be discussing the National Near Miss Reporting System and program with Chief Steve Mormino, NMRS Program Advisor past Chief with South Farmingdale (NY) Fire Department and retired Lieutenant , FDNY. Tune in for an exceptional program.

 

  • Dont’t forget to visit the National Firefighter Near-Miss Reporting System booth at FDIC next month

For more information:
Rynnel Gibbs      
nearmiss@iafc.org
703-537-4858 www.firefighternearmiss.com   

 Near Miss Reporting System Advisory Board

  • Dennis Smith, Chairman, First Responders Financial Co. (Chair of Advisory Board)
  • Jim Brinkley, Director of Occupational Health and Safety, International Association of Fire Fighters.
  • Alan Brunacini, Fire Chief
  • Linda Connell, Director, NASA/Aviation Safety Reporting System
  • I. David Daniels, Fire Chief/CEO, Woodinville Fire and Rescue (WA)
  • Gordon Graham, Graham Research Consultants
  • William Goldfeder, Deputy Chief, Loveland-Symmes Fire Dept. (OH)
  • Manuel Gomez, Chief, City of Hobbs Fire Dept. (NM)
  • Bill Halmich, Fire Chief, Washington Fire Dept. (MO)
  • Christopher Hart, Vice Chair, National Transportation Safety Board
  • Mark Light, Executive Director/Chief Executive Officer, International Association of Fire Chiefs
  • Ed Mann, State Fire Commissioner, Office of the PA State Fire Commissioner